Matching Items (9)
Filtering by

Clear all filters

151412-Thumbnail Image.png
Description
The theory of quantum electrodynamics predicts that beta decay of the neutron into a proton, electron, and anti-neutrino should be accompanied by a continuous spectrum of photons. A recent experiment, RDK I, reported the first detection of radiative decay photons from neutron beta decay with a branching ratio of (3.09

The theory of quantum electrodynamics predicts that beta decay of the neutron into a proton, electron, and anti-neutrino should be accompanied by a continuous spectrum of photons. A recent experiment, RDK I, reported the first detection of radiative decay photons from neutron beta decay with a branching ratio of (3.09 ± 0.32) × 10-3 in the energy range of 15 keV to 340 keV. This was achieved by prompt coincident detection of an electron and photon, in delayed coincidence with a proton. The photons were detected by using a single bar of bismuth germanate scintillating crystal coupled to an avalanche photodiode. This thesis deals with the follow-up experiment, RDK II, to measure the branching ratio at the level of approximately 1% and the energy spectrum at the level of a few percent. The most significant improvement of RDK II is the use of a photon detector with about an order of magnitude greater solid angle coverage than RDK I. In addition, the detectable energy range has been extended down to approximately 250 eV and up to the endpoint energy of 782 keV. This dissertation presents an overview of the apparatus, development of a new data analysis technique for radiative decay, and results for the ratio of electron-proton-photon coincident Repg to electron-proton coincident Rep events.
ContributorsO'Neill, Benjamin (Author) / Alarcon, Ricardo (Thesis advisor) / Drucker, Jeffery (Committee member) / Lebed, Richard (Committee member) / Comfort, Joseph (Committee member) / Chamberlin, Ralph (Committee member) / Arizona State University (Publisher)
Created2012
151112-Thumbnail Image.png
Description
The Arizona State University Herbarium began in 1896 when Professor Fredrick Irish collected the first recorded Arizona specimen for what was then called the Tempe Normal School - a Parkinsonia microphylla. Since then, the collection has grown to approximately 400,000 specimens of vascular plants and lichens. The most recent project

The Arizona State University Herbarium began in 1896 when Professor Fredrick Irish collected the first recorded Arizona specimen for what was then called the Tempe Normal School - a Parkinsonia microphylla. Since then, the collection has grown to approximately 400,000 specimens of vascular plants and lichens. The most recent project includes the digitization - both the imaging and databasing - of approximately 55,000 vascular plant specimens from Latin America. To accomplish this efficiently, possibilities in non-traditional methods, including both new and existing technologies, were explored. SALIX (semi-automatic label information extraction) was developed as the central tool to handle automatic parsing, along with BarcodeRenamer (BCR) to automate image file renaming by barcode. These two developments, combined with existing technologies, make up the SALIX Method. The SALIX Method provides a way to digitize herbarium specimens more efficiently than the traditional approach of entering data solely through keystroking. Using digital imaging, optical character recognition, and automatic parsing, I found that the SALIX Method processes data at an average rate that is 30% faster than typing. Data entry speed is dependent on user proficiency, label quality, and to a lesser degree, label length. This method is used to capture full specimen records, including close-up images where applicable. Access to biodiversity data is limited by the time and resources required to digitize, but I have found that it is possible to do so at a rate that is faster than typing. Finally, I experiment with the use of digital field guides in advancing access to biodiversity data, to stimulate public engagement in natural history collections.
ContributorsBarber, Anne Christine (Author) / Landrum, Leslie R. (Thesis advisor) / Wojciechowski, Martin F. (Thesis advisor) / Gilbert, Edward (Committee member) / Lafferty, Daryl (Committee member) / Arizona State University (Publisher)
Created2012
150778-Thumbnail Image.png
Description
This thesis deals with the first measurements done with a cold neutron beam at the Spallation Neutron Source at Oak Ridge National Laboratory. The experimental technique consisted of capturing polarized cold neutrons by nuclei to measure parity-violation in the angular distribution of the gamma rays following neutron capture. The measurements

This thesis deals with the first measurements done with a cold neutron beam at the Spallation Neutron Source at Oak Ridge National Laboratory. The experimental technique consisted of capturing polarized cold neutrons by nuclei to measure parity-violation in the angular distribution of the gamma rays following neutron capture. The measurements presented here for the nuclei Chlorine ( 35Cl) and Aluminum ( 27Al ) are part of a program with the ultimate goal of measuring the asymmetry in the angular distribution of gamma rays emitted in the capture of neutrons on protons, with a precision better than 10-8, in order to extract the weak hadronic coupling constant due to pion exchange interaction with isospin change equal with one ( hπ 1). Based on theoretical calculations asymmetry in the angular distribution of the gamma rays from neutron capture on protons has an estimated size of 5·10-8. This implies that the Al parity violation asymmetry and its uncertainty have to be known with a precision smaller than 4·10-8. The proton target is liquid Hydrogen (H2) contained in an Aluminum vessel. Results are presented for parity violation and parity-conserving asymmetries in Chlorine and Aluminum. The systematic and statistical uncertainties in the calculation of the parity-violating and parity-conserving asymmetries are discussed.
ContributorsBalascuta, Septimiu (Author) / Alarcon, Ricardo (Thesis advisor) / Belitsky, Andrei (Committee member) / Doak, Bruce (Committee member) / Comfort, Joseph (Committee member) / Schmidt, Kevin (Committee member) / Arizona State University (Publisher)
Created2012
157327-Thumbnail Image.png
Description
The challenge of radiation therapy is to maximize the dose to the tumor while simultaneously minimizing the dose elsewhere. Proton therapy is well suited to this challenge due to the way protons slow down in matter. As the proton slows down, the rate of energy loss per unit path length

The challenge of radiation therapy is to maximize the dose to the tumor while simultaneously minimizing the dose elsewhere. Proton therapy is well suited to this challenge due to the way protons slow down in matter. As the proton slows down, the rate of energy loss per unit path length continuously increases leading to a sharp dose near the end of range. Unlike conventional radiation therapy, protons stop inside the patient, sparing tissue beyond the tumor. Proton therapy should be superior to existing modalities, however, because protons stop inside the patient, there is uncertainty in the range. “Range uncertainty” causes doctors to take a conservative approach in treatment planning, counteracting the advantages offered by proton therapy. Range uncertainty prevents proton therapy from reaching its full potential.

A new method of delivering protons, pencil-beam scanning (PBS), has become the new standard for treatment over the past few years. PBS utilizes magnets to raster scan a thin proton beam across the tumor at discrete locations and using many discrete pulses of typically 10 ms duration each. The depth is controlled by changing the beam energy. The discretization in time of the proton delivery allows for new methods of dose verification, however few devices have been developed which can meet the bandwidth demands of PBS.

In this work, two devices have been developed to perform dose verification and monitoring with an emphasis placed on fast response times. Measurements were performed at the Mayo Clinic. One detector addresses range uncertainty by measuring prompt gamma-rays emitted during treatment. The range detector presented in this work is able to measure the proton range in-vivo to within 1.1 mm at depths up to 11 cm in less than 500 ms and up to 7.5 cm in less than 200 ms. A beam fluence detector presented in this work is able to measure the position and shape of each beam spot. It is hoped that this work may lead to a further maturation of detection techniques in proton therapy, helping the treatment to reach its full potential to improve the outcomes in patients.
ContributorsHolmes, Jason M (Author) / Alarcon, Ricardo (Thesis advisor) / Bues, Martin (Committee member) / Galyaev, Eugene (Committee member) / Chamberlin, Ralph (Committee member) / Arizona State University (Publisher)
Created2019
153631-Thumbnail Image.png
Description
With the discovery of the Higgs Boson in 2012, particle physics has decidedly moved beyond the Standard Model into a new epoch. Though the Standard Model particle content is now completely accounted for, there remain many theoretical issues about the structure of the theory in need of resolution. Among these

With the discovery of the Higgs Boson in 2012, particle physics has decidedly moved beyond the Standard Model into a new epoch. Though the Standard Model particle content is now completely accounted for, there remain many theoretical issues about the structure of the theory in need of resolution. Among these is the hierarchy problem: since the renormalized Higgs mass receives quadratic corrections from a higher cutoff scale, what keeps the Higgs boson light? Many possible solutions to this problem have been advanced, such as supersymmetry, Randall-Sundrum models, or sub-millimeter corrections to gravity. One such solution has been advanced by the Lee-Wick Standard Model. In this theory, higher-derivative operators are added to the Lagrangian for each Standard Model field, which result in propagators that possess two physical poles and fall off more rapidly in the ultraviolet regime. It can be shown by an auxiliary field transformation that the higher-derivative theory is identical to positing a second, manifestly renormalizable theory in which new fields with opposite-sign kinetic and mass terms are found. These so-called Lee-Wick fields have opposite-sign propagators, and famously cancel off the quadratic divergences that plague the renormalized Higgs mass. The states in the Hilbert space corresponding to Lee-Wick particles have negative norm, and implications for causality and unitarity are examined.

This dissertation explores a variant of the theory called the N = 3 Lee-Wick

Standard Model. The Lagrangian of this theory features a yet-higher derivative operator, which produces a propagator with three physical poles and possesses even better high-energy behavior than the minimal Lee-Wick theory. An analogous auxiliary field transformation takes this higher-derivative theory into a renormalizable theory with states of alternating positive, negative, and positive norm. The phenomenology of this theory is examined in detail, with particular emphasis on the collider signatures of Lee-Wick particles, electroweak precision constraints on the masses that the new particles can take on, and scenarios in early-universe cosmology in which Lee-Wick particles can play a significant role.
ContributorsTerBeek, Russell Henry (Author) / Lebed, Richard F (Thesis advisor) / Alarcon, Ricardo (Committee member) / Belitsky, Andrei (Committee member) / Chamberlin, Ralph (Committee member) / Parikh, Maulik (Committee member) / Arizona State University (Publisher)
Created2015
154451-Thumbnail Image.png
Description
A series of experiments using a polarized beam incident on a polarized frozen spin target

(FROST) was conducted at Jefferson Lab in 2010. Results presented here were taken

during the second running period with the FROST target using the CEBAF Large Acceptance

Spectrometer (CLAS) detector at Jefferson Lab, which used transversely-polarized

protons in a

A series of experiments using a polarized beam incident on a polarized frozen spin target

(FROST) was conducted at Jefferson Lab in 2010. Results presented here were taken

during the second running period with the FROST target using the CEBAF Large Acceptance

Spectrometer (CLAS) detector at Jefferson Lab, which used transversely-polarized

protons in a butanol target and a circularly-polarized incident tagged photon beam with

energies between 0.62 and 2.93 GeV. Data are presented for the F and T polarization observables

for h meson photoproduction on the proton from W = 1.55 GeV to 1.80 GeV.

The data presented here will improve the world database and refine theoretical approaches

of nucleon structure.
ContributorsTucker, Ross (Author) / Ritchie, Barry (Thesis advisor) / Dugger, Michael (Committee member) / Alarcon, Ricardo (Committee member) / Lebed, Richard (Committee member) / Arizona State University (Publisher)
Created2016
154376-Thumbnail Image.png
Description
The muon problem of flavor physics presents a rich opportunity to study beyond standard model physics. The as yet undiscovered bound state (μ+μ-), called true muonium, presents a unique opportunity to investigate the muon problem. The near-future experimental searches for true muonium will produce it relativistically, preventing the easy application

The muon problem of flavor physics presents a rich opportunity to study beyond standard model physics. The as yet undiscovered bound state (μ+μ-), called true muonium, presents a unique opportunity to investigate the muon problem. The near-future experimental searches for true muonium will produce it relativistically, preventing the easy application of non-relativistic quantum mechanics. In this thesis, quantum field theory methods based on light-front quantization are used to solve an effective Hamiltonian for true muonium in the Fock space of |μ+μ-> , |μ+μ-γ> , |e+e->, |e+e-γ>, |τ+τ-> , and |τ+τ-γ> . To facilitate these calculations a new parallel code, True Muonium Solver With Front-Form Techniques (TMSWIFT), has been developed. Using this code, numerical results for the wave functions, energy levels, and decay constants of true muonium have been obtained for a range of coupling constants α. Work is also presented for deriving the effective interaction arising from the |γγ sector’s inclusion into the model.
ContributorsLamm, Henry (Author) / Lebed, Richard F (Thesis advisor) / Belitsky, Andrei (Committee member) / Alarcon, Ricardo (Committee member) / Easson, Damien (Committee member) / Arizona State University (Publisher)
Created2016
168718-Thumbnail Image.png
Description
The spectra of predicted particles from elementary quark models (CQMs) are expansive, accurate for the low-lying spectra, but incomplete. The GlueX experiment at Jefferson Lab is a vehicle to study medium energy photoproduction of hadronic states. The primary goal of the GlueX collaboration is to study Quantum Chromodynamics (QCD, also

The spectra of predicted particles from elementary quark models (CQMs) are expansive, accurate for the low-lying spectra, but incomplete. The GlueX experiment at Jefferson Lab is a vehicle to study medium energy photoproduction of hadronic states. The primary goal of the GlueX collaboration is to study Quantum Chromodynamics (QCD, also known as the strong nuclear force) and the nature of quark confinement. The GlueX collaboration uses a polarized photon beam incident on a liquid hydrogen target (LH2) to investigate the aftermath of photon-proton interactions.The cascade baryons, denoted by Ξ, are defined by having two, second-generation, strange quarks with an additional first-generation light quark (u or d). Experimentally, few cascades have been discovered, which is the antithesis of what most models expect. The cascades have some favorable attributes but are difficult to detect because the production cross sections are small and direct production is unlikely. Fortunately, in the 12 GeV era of the GlueX experiment, there is sufficient energy, beam time and data analysis tools for the detection of excited cascade states and their properties. From the reaction γp→K^+ K^+ Ξ^- π^0, the invariant mass spectra of Ξ^- π^0 system was surveyed for new possible resonances. The invariant mass spectrum has a strong Ξ(1530) signal with other smaller resonances throughout the spectrum. Preliminary cross sections for the Ξ(1530) that was photoproduced from the proton are presented at energies never before explored. While the Ξ(1530) couples almost exclusively to the Ξπ channel, there is an easily identifiable Ξ(1690) signal decaying Ξπ. Through the use of a simultaneous fitting routing of the Ξ*- mass spectra, I was able to observe the Ξ(1690) decaying to the KΛ, as well as to the Ξ-π0 branch. With additional statistics, a measurement of the branching ratio should be possible. Lastly, a partial wave analysis (PWA) was completed to verify that the total angular momentum of Ξ(1530) is J = 3/2 and consistent with having positive parity. Additionally, there is evidence of a potentially interesting feature slightly above the mass of the Ξ(1530) that should be more fully explored as new GlueX data becomes available.
ContributorsSumner, Brandon Christopher Lamont (Author) / Dugger, Michael (Thesis advisor) / Ritchie, Barry (Committee member) / Lebed, Richard (Committee member) / Alarcon, Ricardo (Committee member) / Arizona State University (Publisher)
Created2022
157900-Thumbnail Image.png
Description
Readout Integrated Circuits(ROICs) are important components of infrared(IR) imag

ing systems. Performance of ROICs affect the quality of images obtained from IR

imaging systems. Contemporary infrared imaging applications demand ROICs that

can support large dynamic range, high frame rate, high output data rate, at low

cost, size and power. Some of these applications are

Readout Integrated Circuits(ROICs) are important components of infrared(IR) imag

ing systems. Performance of ROICs affect the quality of images obtained from IR

imaging systems. Contemporary infrared imaging applications demand ROICs that

can support large dynamic range, high frame rate, high output data rate, at low

cost, size and power. Some of these applications are military surveillance, remote

sensing in space and earth science missions and medical diagnosis. This work focuses

on developing a ROIC unit cell prototype for National Aeronautics and Space Ad

ministration(NASA), Jet Propulsion Laboratory’s(JPL’s) space applications. These

space applications also demand high sensitivity, longer integration times(large well

capacity), wide operating temperature range, wide input current range and immunity

to radiation events such as Single Event Latchup(SEL).

This work proposes a digital ROIC(DROIC) unit cell prototype of 30ux30u size,

to be used mainly with NASA JPL’s High Operating Temperature Barrier Infrared

Detectors(HOT BIRDs). Current state of the art DROICs achieve a dynamic range

of 16 bits using advanced 65-90nm CMOS processes which adds a lot of cost overhead.

The DROIC pixel proposed in this work uses a low cost 180nm CMOS process and

supports a dynamic range of 20 bits operating at a low frame rate of 100 frames per

second(fps), and a dynamic range of 12 bits operating at a high frame rate of 5kfps.

The total electron well capacity of this DROIC pixel is 1.27 billion electrons, enabling

integration times as long as 10ms, to achieve better dynamic range. The DROIC unit

cell uses an in-pixel 12-bit coarse ADC and an external 8-bit DAC based fine ADC.

The proposed DROIC uses layout techniques that make it immune to radiation up to

300krad(Si) of total ionizing dose(TID) and single event latch-up(SEL). It also has a

wide input current range from 10pA to 1uA and supports detectors operating from

Short-wave infrared (SWIR) to longwave infrared (LWIR) regions.
ContributorsPraveen, Subramanya Chilukuri (Author) / Bakkaloglu, Bertan (Thesis advisor) / Kitchen, Jennifer (Committee member) / Long, Yu (Committee member) / Arizona State University (Publisher)
Created2019