Matching Items (11)
Filtering by

Clear all filters

136814-Thumbnail Image.png
Description
The goal of this project was to explore biomimetics by creating a jellyfish flying device that uses propulsion of air to levitate while utilizing electromyography signals and infrared signals as mechanisms to control the device. Completing this project would require knowledge of biological signals, electrical circuits, computer programming, and physics

The goal of this project was to explore biomimetics by creating a jellyfish flying device that uses propulsion of air to levitate while utilizing electromyography signals and infrared signals as mechanisms to control the device. Completing this project would require knowledge of biological signals, electrical circuits, computer programming, and physics to accomplish. An EMG sensor was used to obtain processed electrical signals produced from the muscles in the forearm and was then utilized to control the actuation speed of the tentacles. An Arduino microprocessor was used to translate the EMG signals to infrared blinking sequences which would propagate commands through a constructed circuit shield to the infrared receiver on jellyfish. The receiver will then translate the received IR sequence into actions. Then the flying device must produce enough thrust to propel the body upwards. The application of biomimetics would best test my skills as an engineer as well as provide a method of applying what I have learned over the duration of my undergraduate career.
ContributorsTsui, Jessica W (Author) / Muthuswamy, Jitteran (Thesis director) / Blain Christen, Jennifer (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor)
Created2014-05
137098-Thumbnail Image.png
Description
This paper summarizes the [1] ideas behind, [2] needs, [3] development, and [4] testing of 3D-printed sensor-stents known as Stentzors. This sensor was successfully developed entirely from scratch, tested, and was found to have an output of 3.2*10-6 volts per RMS pressure in pascals. This paper also recommends further work

This paper summarizes the [1] ideas behind, [2] needs, [3] development, and [4] testing of 3D-printed sensor-stents known as Stentzors. This sensor was successfully developed entirely from scratch, tested, and was found to have an output of 3.2*10-6 volts per RMS pressure in pascals. This paper also recommends further work to render the Stentzor deployable in live subjects, including [1] further design optimization, [2] electrical isolation, [3] wireless data transmission, and [4] testing for aneurysm prevention.
ContributorsMeidinger, Aaron Michael (Author) / LaBelle, Jeffrey (Thesis director) / Frakes, David (Committee member) / Barrett, The Honors College (Contributor) / Mechanical and Aerospace Engineering Program (Contributor)
Created2014-05
137067-Thumbnail Image.png
Description
Growing concern over health risks associated with environmental contaminants has prompted an increase in the search for effective detection methods. The available options provide acceptable sensitivity and specificity, but with high purchase and maintenance costs. Herein, a low-cost, portable environmental contaminant sensor was developed using electrochemical techniques and an efficient

Growing concern over health risks associated with environmental contaminants has prompted an increase in the search for effective detection methods. The available options provide acceptable sensitivity and specificity, but with high purchase and maintenance costs. Herein, a low-cost, portable environmental contaminant sensor was developed using electrochemical techniques and an efficient hydrogel capture mechanism. The sensor operates with high sensitivity and maintains specificity without the added requirement of extensive electrode modification. Rather, specificity is obtained by choosing specific potential regions in which individual contaminants show reduction or oxidation activity. A calibration curve was generated showing the utility of the sensor in detecting gas compounds reliably in reference to a current state of the art sensor. Reusability of the sensor was also demonstrated with a cyclic exposure test in which response reversibility was observed. As such, the investigated sensor shows great promise as a replacement technology in the current environmental contaminant detector industry.
ContributorsMarch, Michael Stephen (Author) / LaBelle, Jeffrey (Thesis director) / Caplan, Michael (Committee member) / Barrett, The Honors College (Contributor) / School of Mathematical and Statistical Sciences (Contributor) / Harrington Bioengineering Program (Contributor)
Created2014-05
137263-Thumbnail Image.png
Description
Diabetes mellitus is a disease characterized by many chronic and acute conditions. With the prevalence and cost quickly increasing, we seek to improve on the current standard of care and create a rapid, label free sensor for glycated albumin (GA) index using electrochemical impedance spectroscopy (EIS). The antibody, anti-HA, was

Diabetes mellitus is a disease characterized by many chronic and acute conditions. With the prevalence and cost quickly increasing, we seek to improve on the current standard of care and create a rapid, label free sensor for glycated albumin (GA) index using electrochemical impedance spectroscopy (EIS). The antibody, anti-HA, was fixed to gold electrodes and a sine wave of sweeping frequencies was induced with a range of HA, GA, and GA with HA concentrations. Each frequency in the impedance sweep was analyzed for highest response and R-squared value. The frequency with both factors optimized is specific for both the antibody-antigen binding interactions with HA and GA and was determined to be 1476 Hz and 1.18 Hz respectively in purified solutions. The correlation slope between the impedance response and concentration for albumin (0 \u2014 5400 mg/dL of albumin) was determined to be 72.28 ohm/ln(mg/dL) with an R-square value of 0.89 with a 2.27 lower limit of detection. The correlation slope between the impedance response and concentration for glycated albumin (0 \u2014 108 mg/dL) was determined to be -876.96 ohm/ln(mg/dL) with an R-squared value of 0.70 with a 0.92 mg/dL lower limit of detection (LLD). The above data confirms that EIS offers a new method of GA detection by providing unique correlation with albumin as well as glycated albumin. The unique frequency response of GA and HA allows for modulation of alternating current signals so that several other markers important in the management of diabetes could be measured with a single sensor. Future work will be necessary to establish multimarker sensing on one electrode.
ContributorsEusebio, Francis Ang (Author) / LaBelle, Jeffrey (Thesis director) / Pizziconi, Vincent (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor)
Created2014-05
136262-Thumbnail Image.png
Description
The Larynx plays a pivotal role in our ability to breathe and to speak. It is in our best interest to continue improving the status of tissue regeneration concerning the larynx so that patient voice quality of life can be less hindered in the face of laryngeal cancers and diseases.

The Larynx plays a pivotal role in our ability to breathe and to speak. It is in our best interest to continue improving the status of tissue regeneration concerning the larynx so that patient voice quality of life can be less hindered in the face of laryngeal cancers and diseases. Modern technology can allow us to use CT scans for both diagnosis and treatment. This medical imaging can be converted into three-dimensional patient specific models that are actualized through 3D printing. These implants improve upon the current state of the art because they can be produced in a timely manner, are developed with materials and methods ensuring their biocompatibility, and follow architectures and geometries best suited for the patient to improve their voice quality of life. Additionally they should be able to allow patient speech in the case of partial laryngectomies where the arytenoid has been removed by acting as a permanent vocal fold This treatment process for laryngectomies aligns itself with personalized medicine by targeting its geometry based on that of the patient. Technologies and manufacturing processes utilized to produce them are accessible and could all be used within the clinical space. The life-saving implant required for the laryngectomy healing and recovery process can be ready to implant for the patient within a few days of imaging them.
ContributorsBarry, Colin Patrick (Author) / Pizziconi, Vincent (Thesis director) / Lott, David (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor)
Created2015-05
134209-Thumbnail Image.png
Description
Polymer modified tuning fork-based sensors were fabricated to assure reproducibility. The effect of system valve switching on the modified tuning fork-based sensors was studied at the different temperature. The response to Xylene gas sample on stabilized modified tuning fork-based sensors with temperature was defined while learning about the key analytical

Polymer modified tuning fork-based sensors were fabricated to assure reproducibility. The effect of system valve switching on the modified tuning fork-based sensors was studied at the different temperature. The response to Xylene gas sample on stabilized modified tuning fork-based sensors with temperature was defined while learning about the key analytical performance for chemical sensors to be used in the real-world application.
ContributorsRohit, Riddhi S (Author) / Forzani, Erica (Thesis director) / Tsow, Francis (Committee member) / Dean, W.P. Carey School of Business (Contributor) / Chemical Engineering Program (Contributor) / Barrett, The Honors College (Contributor)
Created2017-05
Description

3D printing prosthetics for amputees is an innovative opportunity to provide a lower cost and customized alternative to current technologies. Companies, such as E-NABLE and YouBionic are developing myoelectric prosthetics, electrically powered terminal devices activated by electromyography (EMG), for transradial amputees. Prosthetics that are 3D printed are less expensive for

3D printing prosthetics for amputees is an innovative opportunity to provide a lower cost and customized alternative to current technologies. Companies, such as E-NABLE and YouBionic are developing myoelectric prosthetics, electrically powered terminal devices activated by electromyography (EMG), for transradial amputees. Prosthetics that are 3D printed are less expensive for juvenile use, more sustainable, and more accessible for those without insurance. Although they are typically not outfitted with the same complex grip patterns or durability of a traditional myoelectric prosthetic, they offer a sufficient durability (withstanding up to 150 N on average) and allow for new opportunities in prosthetic development. Devils Prosthetics, a student research and development group associated with Engineering Projects in Community Service (EPICS), has investigated the benefits and pitfalls of utilizing polyethylene terephthalate glycol (PETG) for 3D printing prosthetics as well as combining a MyoWare EMG sensor with machine learning for optimal control of the prosthetic.

ContributorsAlessio, Gabriella (Author) / Gryskiewicz, Jarek (Co-author) / Hiramine, Jason (Co-author) / Schoepf, Jared (Thesis director) / Shimono, Satoshi (Committee member) / Nemgar, Noah (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor) / College of Integrative Sciences and Arts (Contributor)
Created2023-05
Description

3D printing prosthetics for amputees is an innovative opportunity to provide a lower cost and customized alternative to current technologies. Companies, such as E-NABLE and YouBionic are developing myoelectric prosthetics, electrically powered terminal devices activated by electromyography (EMG), for transradial amputees. Prosthetics that are 3D printed are less expensive for

3D printing prosthetics for amputees is an innovative opportunity to provide a lower cost and customized alternative to current technologies. Companies, such as E-NABLE and YouBionic are developing myoelectric prosthetics, electrically powered terminal devices activated by electromyography (EMG), for transradial amputees. Prosthetics that are 3D printed are less expensive for juvenile use, more sustainable, and more accessible for those without insurance. Although they are typically not outfitted with the same complex grip patterns or durability of a traditional myoelectric prosthetic, they offer a sufficient durability (withstanding up to 150 N on average) and allow for new opportunities in prosthetic development. Devils Prosthetics, a student research and development group associated with Engineering Projects in Community Service (EPICS), has investigated the benefits and pitfalls of utilizing polyethylene terephthalate glycol (PETG) for 3D printing prosthetics as well as combining a MyoWare EMG sensor with machine learning for optimal control of the prosthetic.

ContributorsGryskiewicz, Jarek (Author) / Alessio, Gabby (Co-author) / Hiramina, Jason (Co-author) / Schoepf, Jared (Thesis director) / Shimono, Satoshi (Committee member) / Nemgar, Noah (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor)
Created2023-05
Description

3D printing prosthetics for amputees is an innovative opportunity to provide a lower cost and customized alternative to current technologies. Companies, such as E-NABLE and YouBionic are developing myoelectric prosthetics, electrically powered terminal devices activated by electromyography (EMG), for transradial amputees. Prosthetics that are 3D printed are less expensive for

3D printing prosthetics for amputees is an innovative opportunity to provide a lower cost and customized alternative to current technologies. Companies, such as E-NABLE and YouBionic are developing myoelectric prosthetics, electrically powered terminal devices activated by electromyography (EMG), for transradial amputees. Prosthetics that are 3D printed are less expensive for juvenile use, more sustainable, and more accessible for those without insurance. Although they are typically not outfitted with the same complex grip patterns or durability of a traditional myoelectric prosthetic, they offer a sufficient durability (withstanding up to 150 N on average) and allow for new opportunities in prosthetic development. Devils Prosthetics, a student research and development group associated with Engineering Projects in Community Service (EPICS), has investigated the benefits and pitfalls of utilizing polyethylene terephthalate glycol (PETG) for 3D printing prosthetics as well as combining a MyoWare EMG sensor with machine learning for optimal control of the prosthetic.

ContributorsHiramine, Jason (Author) / Alessio, Gabriella (Co-author) / Gryskiewicz, Jarek (Co-author) / Schoepf, Jared (Thesis director) / Shimono, Satoshi (Committee member) / Nemgar, Noah (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor) / School of Mathematical and Statistical Sciences (Contributor)
Created2023-05
165856-Thumbnail Image.png
Description

Realtime understanding of one’s complete metabolic state is crucial to controlling weight and managing chronic illnesses, such as diabetes. This project represents the development of a novel breath acetone sensor within the Biodesign Institute’s Center for Bioelectronics and Biosensors. The purpose is to determine if a sensor can be manufactured

Realtime understanding of one’s complete metabolic state is crucial to controlling weight and managing chronic illnesses, such as diabetes. This project represents the development of a novel breath acetone sensor within the Biodesign Institute’s Center for Bioelectronics and Biosensors. The purpose is to determine if a sensor can be manufactured with the capacity to measure breath acetone concentrations typical of various levels of metabolic activity. For this purpose, a solution that selectively interacts with acetone was embedded in a sensor cartridge that is permeable to volatile organic compounds. After 30 minutes of exposure to a range of acetone concentrations, a color change response was observed in the sensors. Requiring only exposure to a breath, these novel sensor configurations may offer non-trivial improvements to clinical and at-home measurement of lipid metabolic rate.

ContributorsDenham, Landon (Author) / Forzani, Erica (Thesis director) / Mora, Sabrina Jimena (Committee member) / Barrett, The Honors College (Contributor) / Chemical Engineering Program (Contributor)
Created2022-05