Matching Items (4)
Filtering by

Clear all filters

152201-Thumbnail Image.png
Description
Coronary computed tomography angiography (CTA) has a high negative predictive value for ruling out coronary artery disease with non-invasive evaluation of the coronary arteries. My work has attempted to provide metrics that could increase the positive predictive value of coronary CTA through the use of dual energy CTA imaging. After

Coronary computed tomography angiography (CTA) has a high negative predictive value for ruling out coronary artery disease with non-invasive evaluation of the coronary arteries. My work has attempted to provide metrics that could increase the positive predictive value of coronary CTA through the use of dual energy CTA imaging. After developing an algorithm for obtaining calcium scores from a CTA exam, a dual energy CTA exam was performed on patients at dose levels equivalent to levels for single energy CTA with a calcium scoring exam. Calcium Agatston scores obtained from the dual energy CTA exam were within ±11% of scores obtained with conventional calcium scoring exams. In the presence of highly attenuating coronary calcium plaques, the virtual non-calcium images obtained with dual energy CTA were able to successfully measure percent coronary stenosis within 5% of known stenosis values, which is not possible with single energy CTA images due to the presence of the calcium blooming artifact. After fabricating an anthropomorphic beating heart phantom with coronary plaques, characterization of soft plaque vulnerability to rupture or erosion was demonstrated with measurements of the distance from soft plaque to aortic ostium, percent stenosis, and percent lipid volume in soft plaque. A classification model was developed, with training data from the beating heart phantom and plaques, which utilized support vector machines to classify coronary soft plaque pixels as lipid or fibrous. Lipid versus fibrous classification with single energy CTA images exhibited a 17% error while dual energy CTA images in the classification model developed here only exhibited a 4% error. Combining the calcium blooming correction and the percent lipid volume methods developed in this work will provide physicians with metrics for increasing the positive predictive value of coronary CTA as well as expanding the use of coronary CTA to patients with highly attenuating calcium plaques.
ContributorsBoltz, Thomas (Author) / Frakes, David (Thesis advisor) / Towe, Bruce (Committee member) / Kodibagkar, Vikram (Committee member) / Pavlicek, William (Committee member) / Bouman, Charles (Committee member) / Arizona State University (Publisher)
Created2013
Description
Cardiovascular diseases (CVDs) are the leading cause of mortality worldwide, causing nearly 25% of deaths in the United States. Despite the efforts to create in vitro models for the study and treatment of CVDs, these are still limited in their recapitulation of the heart tissue. Thus, the engineering of accurate

Cardiovascular diseases (CVDs) are the leading cause of mortality worldwide, causing nearly 25% of deaths in the United States. Despite the efforts to create in vitro models for the study and treatment of CVDs, these are still limited in their recapitulation of the heart tissue. Thus, the engineering of accurate cardiac models is imperative to gain more understanding and improve the outcome of CVDs. This Ph.D. dissertation focuses on the development and characterization of isogenic cardiac organoids derived from human induced pluripotent stem cells (hiPSCs). Additionally, the integration of chemical and biological cues for enriching their microenvironment and promoting their maturation state and function were studied. First, hiPSC-derived cardiac cells were utilized for the fabrication of multicellular spherical microtissues, namely isogenic cardiac organoids. The cellular composition and culture time of the engineered tissues were optimized to induce cellular aggregation and the formation of cell-cell interactions. Also, ribbon-like gold nanoparticles, namely gold nanoribbons (AuNRs), were synthesized, characterized, and biofunctionalized for their integration into the isogenic cardiac organoids. In-depth biological evaluation of the organoids showed enhanced cardiac maturation markers. Furthermore, a supplement-free cell culture regime was designed and evaluated for fabricating isogenic cardiac organoids. Mechanistic, cellular, and molecular-level studies demonstrated that the presence of hiPSC-derived cardiac fibroblasts (hiPSC-CFs) significantly improves the morphology and gene expression profile of the organoids. Electrophysiological-relevant features of the organoids, such as conduction velocity (CV), were further investigated utilizing a microelectrode array (MEA) platform. It was shown that MEA offers a simple, yet powerful approach to assessing electrophysiological responses of the tissues, where a trend in decreased CV was found due to the presence of hiPSC-CFs. Overall, this dissertation has a broad impact casting light on the development strategy and biological mechanisms that govern the formation and function of isogenic cardiac organoids. Moreover, this study presents two unique approaches to promote maturation of stem cell-derived cardiac organoids: 1) through the integration of novel biofunctionalized nanomaterials, and 2) through a cell culture regime, leading to enhanced function of the organoids. The proposed micro-engineered organoids have broad applications as physiologically relevant tissues for drug discovery, CVDs modeling, and regenerative medicine.
ContributorsPatino, Alejandra (Author) / Nikkhah, Medhi (Thesis advisor) / Blain-Christen, Jennifer (Committee member) / Kodibagkar, Vikram (Committee member) / Vernon, Brent (Committee member) / Zhu, Wuqiang (Committee member) / Arizona State University (Publisher)
Created2023
156620-Thumbnail Image.png
Description
Monitoring complex diseases and their comorbidities requires accurate and convenient measurements of multiple biomarkers. However, many state-of-the-art bioassays not only require complicated and time-consuming procedures, but also measure only one biomarker at a time. This noncomprehensive single-biomarker monitoring, as well as the cost and complexity of these bioassays advocate for

Monitoring complex diseases and their comorbidities requires accurate and convenient measurements of multiple biomarkers. However, many state-of-the-art bioassays not only require complicated and time-consuming procedures, but also measure only one biomarker at a time. This noncomprehensive single-biomarker monitoring, as well as the cost and complexity of these bioassays advocate for a simple, rapid multi-marker sensing platform suitable for point-of-care or self-monitoring settings. To address this need, diabetes mellitus was selected as the example complex disease, with dry eye disease and cardiovascular disease as the example comorbidities. Seven vital biomarkers from these diseases were selected to investigate the platform technology: lactoferrin (Lfn), immunoglobulin E (IgE), insulin, glucose, lactate, low density lipoprotein (LDL), and high density lipoprotein (HDL). Using electrochemical techniques such as amperometry and electrochemical impedance spectroscopy (EIS), various single- and dual-marker sensing prototypes were studied. First, by focusing on the imaginary impedance of EIS, an analytical algorithm for the determination of optimal frequency and signal deconvolution was first developed. This algorithm helped overcome the challenge of signal overlapping in EIS multi-marker sensors, while providing a means to study the optimal frequency of a biomarker. The algorithm was then applied to develop various single- and dual-marker prototypes by exploring different kinds of molecular recognition elements (MRE) while studying the optimal frequencies of various biomarkers with respect to their biological properties. Throughout the exploration, 5 single-marker biosensors (glucose, lactate, insulin, IgE, and Lfn) and one dual-marker (LDL and HDL) biosensor were successfully developed. With the aid of nanoparticles and the engineering design of experiments, the zeta potential, conductivity, and molecular weight of a biomarker were found to be three example factors that contribute to a biomarker’s optimal frequency. The study platforms used in the study did not achieve dual-enzymatic marker biosensors (glucose and lactate) due to signal contamination from localized accumulation of reduced electron mediators on self-assembled monolayer. However, amperometric biosensors for glucose and lactate with disposable test strips and integrated samplers were successfully developed as a back-up solution to the multi-marker sensing platform. This work has resulted in twelve publications, five patents, and one submitted manuscripts at the time of submission.
ContributorsLin, Chi En (Author) / La Belle, Jeffrey T (Thesis advisor) / Caplan, Michael (Committee member) / Cook, Curtiss B (Committee member) / Stabenfeldt, Sarah (Committee member) / Spano, Mark (Committee member) / Arizona State University (Publisher)
Created2018
Description
Myocardial infarction (MI) remains the leading cause of mortality and morbidity in the U.S., accounting for nearly 140,000 deaths per year. Heart transplantation and implantation of mechanical assist devices are the options of last resort for intractable heart failure, but these are limited by lack of organ donors and potential

Myocardial infarction (MI) remains the leading cause of mortality and morbidity in the U.S., accounting for nearly 140,000 deaths per year. Heart transplantation and implantation of mechanical assist devices are the options of last resort for intractable heart failure, but these are limited by lack of organ donors and potential surgical complications. In this regard, there is an urgent need for developing new effective therapeutic strategies to induce regeneration and restore the loss contractility of infarcted myocardium. Over the past decades, regenerative medicine has emerged as a promising strategy to develop scaffold-free cell therapies and scaffold-based cardiac patches as potential approaches for MI treatment. Despite the progress, there are still critical shortcomings associated with these approaches regarding low cell retention, lack of global cardiomyocytes (CMs) synchronicity, as well as poor maturation and engraftment of the transplanted cells within the native myocardium. The overarching objective of this dissertation was to develop two classes of nanoengineered cardiac patches and scaffold-free microtissues with superior electrical, structural, and biological characteristics to address the limitations of previously developed tissue models. An integrated strategy, based on micro- and nanoscale technologies, was utilized to fabricate the proposed tissue models using functionalized gold nanomaterials (GNMs). Furthermore, comprehensive mechanistic studies were carried out to assess the influence of conductive GNMs on the electrophysiology and maturity of the engineered cardiac tissues. Specifically, the role of mechanical stiffness and nano-scale topographies of the scaffold, due to the incorporation of GNMs, on cardiac cells phenotype, contractility, and excitability were dissected from the scaffold’s electrical conductivity. In addition, the influence of GNMs on conduction velocity of CMs was investigated in both coupled and uncoupled gap junctions using microelectrode array technology. Overall, the key contributions of this work were to generate new classes of electrically conductive cardiac patches and scaffold-free microtissues and to mechanistically investigate the influence of conductive GNMs on maturation and electrophysiology of the engineered tissues.
ContributorsNavaei, Ali (Author) / Nikkhah, Mehdi (Thesis advisor) / Brafman, David (Committee member) / Migrino, Raymond Q. (Committee member) / Stabenfeldt, Sarah (Committee member) / Vernon, Brent (Committee member) / Arizona State University (Publisher)
Created2018