Filtering by
- All Subjects: Biomechanics
- Creators: Lee, Hyunglae
water. Due to the complicated fluid dynamics of this process, the forces applied on the
water’s surface cannot be measured using traditional methods. This thesis presents a
novel technique of measuring the forces using a fluid dynamic force platform (FDFP),
a light, rigid box immersed in water. This platform, along with a motion capture
system, can be used to characterize the kinematics and dynamics of a basilisk lizard
running on water. This could ultimately lead to robots that can run on water in a
similar manner.
A knee exoskeleton and ankle assistive device (Robotic Shoe) are developed and used to provide walking assistance. The knee exoskeleton provides personalized knee joint assistive torque during the stance phase. The robotic shoe is a light-weighted mechanism that can store the potential energy at heel strike and release it by using an active locking mechanism at the terminal stance phase to provide push-up ankle torque and assist the toe-off. Lower-limb Kinematic time series data are collected for subjects wearing these devices in the passive and active mode. The changes of kinematics with and without these devices on lower-limb motion are first studied. Orbital stability, as one of the commonly used measure to quantify gait stability through calculating Floquet Multipliers (FM), is employed to asses the effects of these wearable devices on gait stability. It is shown that wearing the passive knee exoskeleton causes less orbitally stable gait for users, while the knee joint active assistance improves the orbital stability compared to passive mode. The robotic shoe only affects the targeted joint (right ankle) kinematics, and wearing the passive mechanism significantly increases the ankle joint FM values, which indicates less walking orbital stability. More analysis is done on a mechanically perturbed walking public data set, to show that orbital stability can quantify the effects of external mechanical perturbation on gait dynamic stability. This method can further be used as a control design tool to ensure gait stability for users of lower-limb assistive devices.
robots with limited sensing and/or actuating capabilities that cooperate (explicitly
or implicitly) based on local communications and sensing in order to complete a
mission. Its inherent redundancy provides flexibility and robustness to failures and
environmental disturbances which guarantee the proper completion of the required
task. At the same time, human intuition and cognition can prove very useful in
extreme situations where a fast and reliable solution is needed. This idea led to the
creation of the field of Human-Swarm Interfaces (HSI) which attempts to incorporate
the human element into the control of robotic swarms for increased robustness and
reliability. The aim of the present work is to extend the current state-of-the-art in HSI
by applying ideas and principles from the field of Brain-Computer Interfaces (BCI),
which has proven to be very useful for people with motor disabilities. At first, a
preliminary investigation about the connection of brain activity and the observation
of swarm collective behaviors is conducted. After showing that such a connection
may exist, a hybrid BCI system is presented for the control of a swarm of quadrotors.
The system is based on the combination of motor imagery and the input from a game
controller, while its feasibility is proven through an extensive experimental process.
Finally, speech imagery is proposed as an alternative mental task for BCI applications.
This is done through a series of rigorous experiments and appropriate data analysis.
This work suggests that the integration of BCI principles in HSI applications can be
successful and it can potentially lead to systems that are more intuitive for the users
than the current state-of-the-art. At the same time, it motivates further research in
the area and sets the stepping stones for the potential development of the field of
Brain-Swarm Interfaces (BSI).
Oscillatory perturbations with varying amplitudes and frequencies have been found to significantly affect human standing balance. However, previous studies have only applied perturbation in either the anterior-posterior (AP) or the medio-lateral (ML) directions. Little is currently known about the impacts of 2D oscillatory perturbations on postural stability, which are more commonly seen in daily life (i.e., while traveling on trains, ships, etc.). This study investigated the effects of applying 2D perturbations vs 1D perturbations on standing stability, and how increasing the frequency and amplitude of perturbation impacts postural stability. A dual-axis robotic platform was utilized to simulate various oscillatory perturbations and evaluate standing postural stability. Fifteen young healthy subjects were recruited to perform quiet stance on the platform. Impacts of perturbation direction (i.e., 1D versus 2D), amplitude, and frequency on postural stability were investigated by analyzing different stability measures, specifically AP/ML/2D Center-of-Pressure (COP) path length, AP/ML/2D Time-to-Boundary (TtB), and sway area. Standing postural stability was compromised more by 2D perturbations than 1D perturbations, evidenced by a significant increase in COP path length and sway area and decrease in TtB. Further, the stability decreased as 2D perturbation amplitude and frequency increased. A significant increase in COP path length and decrease in TtB were consistently observed as the 2D perturbation amplitude and frequency increased. However, sway area showed a considerable increase only with increasing perturbation amplitude but not with increasing frequency.
This dissertation examined several hurdles that must be overcome to create a standardized method of calculating the LyE for gait data when collected with an accelerometer. In each of the following investigations, both the Rosenstein et al. and Wolf et al. algorithms as well as three normalization methods were applied in order to understand the extent at which these factors affect the LyE. First, the a priori parameters of time delay and embedding dimension which are required for phase space reconstruction were investigated. This study found that the time delay can be standardized to a value of 10 and that an embedding dimension of 5 or 7 should be used for the Rosenstein and Wolf algorithm respectively. Next, the effect of data length on the LyE was examined using 30 to 1300 strides of gait data. This analysis found that comparisons across papers are only possible when similar amounts of data are used but comparing across normalization methods is not recommended. And finally, the reliability and minimum required number of strides for each of the 6 algorithm-normalization method combinations in both young healthy and elderly adults was evaluated. This research found that the Rosenstein algorithm was more reliable and required fewer strides for the calculation of the LyE for an accelerometer.
In order to characterize the ankle mechanics and understand the underlying mechanisms that influence the neuromuscular properties of the ankle, a novel multi-axial robotic platform was developed. The robotic platform is capable of simulating various haptic environments and transiently perturbing the ankle to analyze the neuromechanics of the ankle, specifically the ankle impedance. Humans modulate ankle impedance to perform various tasks of the lower limb. The robotic platform is used to analyze the modulation of ankle impedance during postural balance and locomotion on various haptic environments. Further, various factors that influence modulation of ankle impedance were identified. Using the factors identified during environment dependent impedance modulation studies, the quantitative relationship between these factors, namely the muscle activation of major ankle muscles, the weight loading on ankle and the torque generation at the ankle was analyzed during postural balance and locomotion. A universal neuromuscular model of the ankle that quantitatively relates ankle stiffness, the major component of ankle impedance, to these factors was developed.
This neuromuscular model is then used as a basis to study the alterations caused in ankle behavior due to neurodegenerative disorders such as Multiple Sclerosis and Stroke. Pilot studies to validate the analysis of altered ankle behavior and demonstrate the effectiveness of robotic rehabilitation protocols in addressing the altered ankle behavior were performed. The pilot studies demonstrate that the altered ankle mechanics can be quantified in the affected populations and correlate with the observed adverse effects of the disability. Further, robotic rehabilitation protocols improve ankle control in affected populations as seen through functional improvements in postural balance and locomotion, validating the neuromuscular approach for rehabilitation.