Lower-limb wearable assistive robots could alter the users gait kinematics by inputting external power, which can be interpreted as mechanical perturbation to subject normal gait. The change in kinematics may affect the dynamic stability. This work attempts to understand the effects of different physical assistance from these robots on the

Lower-limb wearable assistive robots could alter the users gait kinematics by inputting external power, which can be interpreted as mechanical perturbation to subject normal gait. The change in kinematics may affect the dynamic stability. This work attempts to understand the effects of different physical assistance from these robots on the gait dynamic stability.

A knee exoskeleton and ankle assistive device (Robotic Shoe) are developed and used to provide walking assistance. The knee exoskeleton provides personalized knee joint assistive torque during the stance phase. The robotic shoe is a light-weighted mechanism that can store the potential energy at heel strike and release it by using an active locking mechanism at the terminal stance phase to provide push-up ankle torque and assist the toe-off. Lower-limb Kinematic time series data are collected for subjects wearing these devices in the passive and active mode. The changes of kinematics with and without these devices on lower-limb motion are first studied. Orbital stability, as one of the commonly used measure to quantify gait stability through calculating Floquet Multipliers (FM), is employed to asses the effects of these wearable devices on gait stability. It is shown that wearing the passive knee exoskeleton causes less orbitally stable gait for users, while the knee joint active assistance improves the orbital stability compared to passive mode. The robotic shoe only affects the targeted joint (right ankle) kinematics, and wearing the passive mechanism significantly increases the ankle joint FM values, which indicates less walking orbital stability. More analysis is done on a mechanically perturbed walking public data set, to show that orbital stability can quantify the effects of external mechanical perturbation on gait dynamic stability. This method can further be used as a control design tool to ensure gait stability for users of lower-limb assistive devices.
ContributorsRezayat Sorkhabadi, Seyed Mostafa (Author) / Zhang, Wenlong (Thesis advisor) / Lee, Hyunglae (Committee member) / Artemiadis, Panagiotis (Committee member) / Arizona State University (Publisher)
Created2018
132475-Thumbnail Image.png
Description
The global population over the age of 60 is estimated to rise to 23% by 2050 only increase the prevalence of functional neurological disorders and stroke. Increase in cases of functional neurological disorders and strokes will place a greater burden on the healthcare industry, specifically physical therapy. Physical therapy is

The global population over the age of 60 is estimated to rise to 23% by 2050 only increase the prevalence of functional neurological disorders and stroke. Increase in cases of functional neurological disorders and strokes will place a greater burden on the healthcare industry, specifically physical therapy. Physical therapy is vital for a patient’s recovery of motor function which is time demanding and taxing on the physical therapist. Wearable robotics have been proven to improve functional outcomes in gait rehabilitation by providing controlled high dosage and high-intensity training. Accurate control strategies for assistive robotic exoskeletons are vital for repetitive high precisions assistance for cerebral plasticity to occur.

This thesis presents a preliminary determination and design of a control algorithm for an assistive ankle device developed by the ASU RISE Laboratory. The assistive ankle device functions by compressing a spring upon heel strike during gait, remaining compressed during mid-stance and then releasing upon initiation of heel-off. The relationship between surface electromyography and ground reactions forces were used for identification of user-initiated heel-off. The muscle activation of the tibialis anterior combined with the ground reaction forces of the heel pressure sensor generated potential features that will be utilized in the revised control algorithm for the assistive ankle device. Work on this project must proceed in order to test and validate the revised control algorithm to determine its accuracy and precision.
ContributorsGaytan-Jenkins, Daniel Rinaldo (Author) / Zhang, Wenlong (Thesis director) / Tyler, Jamie (Committee member) / Harrington Bioengineering Program (Contributor, Contributor) / Barrett, The Honors College (Contributor)
Created2019-05
134994-Thumbnail Image.png
Description
With dwindling water resources due to drought and other pressures, water utilities are seeking to tap into alternative water sources as a means to improve water sustainability. Reclaimed water consists of treated wastewater and is widely used for non-potable purposes, such as irrigation, both agricultural and recreational. However, the reclaimed

With dwindling water resources due to drought and other pressures, water utilities are seeking to tap into alternative water sources as a means to improve water sustainability. Reclaimed water consists of treated wastewater and is widely used for non-potable purposes, such as irrigation, both agricultural and recreational. However, the reclaimed water distribution system can be subject to substantial regrowth of microorganisms, including opportunistic pathogens, even following rigorous disinfection. Factors that can influence regrowth include temperature, organic carbon levels, disinfectant type, and the time transported (i.e., water age) in the system. One opportunistic pathogen (OP) that is critical to understanding microbial activity in both reclaimed and drinking water distribution systems is Acanthamoeba. In order to better understand the potential for this amoeba to proliferate in reclaimed water systems and influence other OPs, a simulated reclaimed water distribution system was studied. The objective of this study was to compare the prevalence of Acanthamoeba and one of its endosymbionts, Legionella, across varying assimilable organic carbon (AOC) levels, temperatures, disinfectants, and water ages in a simulated reclaimed water distribution system. The results of the study showed that cooler temperatures, larger water age, and chlorine conditions yielded the lowest detection of Acanthamoeba gene copies per mL or cm2 for bulk water and biofilm samples, respectively.
ContributorsDonaldson, Kandace (Author) / Ankeny, Casey (Thesis director) / Edwards, Marc (Committee member) / Pruden, Amy (Committee member) / Harrington Bioengineering Program (Contributor) / Barrett, The Honors College (Contributor)
Created2016-12
135593-Thumbnail Image.png
Description
The effect of conflicting sensorimotor memories on optimal force strategies was explored. Subjects operated a virtual object controlled by a physical handle to complete a simple straight-line task. Perturbations applied to the handle induced a period of increased error in subject accuracy. After two blocks of 33 trials, perturbations switched

The effect of conflicting sensorimotor memories on optimal force strategies was explored. Subjects operated a virtual object controlled by a physical handle to complete a simple straight-line task. Perturbations applied to the handle induced a period of increased error in subject accuracy. After two blocks of 33 trials, perturbations switched direction, inducing increased error from the previous trials. Subjects returned after a 24-hour period to complete a similar protocol, but beginning with the second context and ending with the first. Interference from the first context on each day caused an increase in initial error for the second (P < 0.05). Following the rest period, subjects showed retention of the sensorimotor memory from the previous day through significantly decreased initial error (P = 3x10-6). However, subjects showed an increase in forces for each new context resulting from a sub-optimal motor strategy. Higher levels of total effort (P < 0.05) and a lack of separation between force values for opposing and non-opposing digits (P > 0.05) indicated a strategy that used more energy to complete the task, even when rates of learning appeared identical or improved. Two possible mechanisms for this lack of energy conservation have been proposed.
ContributorsSmith, Michael David (Author) / Santello, Marco (Thesis director) / Kleim, Jeffrey (Committee member) / Harrington Bioengineering Program (Contributor) / Barrett, The Honors College (Contributor)
Created2016-05
137074-Thumbnail Image.png
Description
Medial compartment knee osteoarthritis (OA) is a disease whose severity has been associated with the peak adduction moment during walking (pKAM). Unfortunately, measuring patients' pKAM to track their therapy progress involves the use of a gait laboratory which is expensive and time intensive. This study aimed to develop and assess

Medial compartment knee osteoarthritis (OA) is a disease whose severity has been associated with the peak adduction moment during walking (pKAM). Unfortunately, measuring patients' pKAM to track their therapy progress involves the use of a gait laboratory which is expensive and time intensive. This study aimed to develop and assess a regression method to predict the pKAM using only plantar pressure measurements. This approach could greatly reduce the burden of evaluating pKAM.
ContributorsThomas, Kevin Andrew (Author) / Hinrichs, Richard (Thesis director) / Harper, Erin (Committee member) / Favre, Julien (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor)
Created2014-05
157404-Thumbnail Image.png
Description
This thesis presents the design and testing of a soft robotic device for water utility pipeline inspection. The preliminary findings of this new approach to conventional methods of pipe inspection demonstrate that a soft inflatable robot can successfully traverse the interior space of a range of diameter pipes using pneumatic

This thesis presents the design and testing of a soft robotic device for water utility pipeline inspection. The preliminary findings of this new approach to conventional methods of pipe inspection demonstrate that a soft inflatable robot can successfully traverse the interior space of a range of diameter pipes using pneumatic and without the need to adjust rigid, mechanical components. The robot utilizes inflatable soft actuators with an adjustable radius which, when pressurized, can provide a radial force, effectively anchoring the device in place. Additional soft inflatable actuators translate forces along the center axis of the device which creates forward locomotion when used in conjunction with the radial actuation. Furthermore, a bio-inspired control algorithm for locomotion allows the robot to maneuver through a pipe by mimicking the peristaltic gait of an inchworm. This thesis provides an examination and evaluation of the structure and behavior of the inflatable actuators through computational modeling of the material and design, as well as the experimental data of the forces and displacements generated by the actuators. The theoretical results are contrasted with/against experimental data utilizing a physical prototype of the soft robot. The design is anticipated to enable compliant robots to conform to the space offered to them and overcome occlusions from accumulated solids found in pipes. The intent of the device is to be used for inspecting existing pipelines owned and operated by Salt River Project, a Phoenix-area water and electricity utility provider.
ContributorsAdams, Wade Silas (Author) / Aukes, Daniel (Thesis advisor) / Sugar, Thomas (Committee member) / Zhang, Wenlong (Committee member) / Arizona State University (Publisher)
Created2019
158470-Thumbnail Image.png
Description
Traditionally, wearable exoskeletons for gait assistance have addressed the issue of high power requirement of providing support during walking. However, exoskeletons often are bulky, and suffer from misalignment of joints between the robot and the user. Soft robots in recent work have shown the ability to provide a high degree

Traditionally, wearable exoskeletons for gait assistance have addressed the issue of high power requirement of providing support during walking. However, exoskeletons often are bulky, and suffer from misalignment of joints between the robot and the user. Soft robots in recent work have shown the ability to provide a high degree of compliance with a light weight and lower cost. This work presents the design, control, and evaluation of a soft inflatable exosuit to assist knee extension. First, the design of novel soft inflatable actuators of I cross-section and their application in the soft inflatable exosuit is presented. The actuators are applied to a soft and lightweight garment interface to assist in knee extension during the swing phase demonstrating reduced muscle activity for the quadriceps. Second, the control of the soft exosuit is presented with the introduction of a knee angle measurement system and smart shoe insole sensors. A new control method using human joint stiffness models as well as actuator models is developed. The new control method is evaluated with three users and a reduction in the sEMG activity of the quadriceps is observed with an increase in the activity of the hamstrings. Third, an improved version of the exosuit and a controller to assist knee extension in swing phase and initial stance are presented. The exosuit is applied to seven healthy and three impaired participants. Kinematics, muscle activity and gait compensations are studied. Reduced muscle activity for the quadriceps is seen in healthy participants with reduced execution times for functional activities such as timed up-and-go as well as sit-to-stand transitions in impaired participants. Finally, an untethered version of the soft exosuit using inflatable actuator composites and a portable pneumatic source are presented. Finite element models for the composites and inflatable actuators are generated and the actuators are characterized for performance. The design of a portable source for the exosuit is also presented. The inflatable actuator composites and the portable source are implemented in a portable exosuit system which demonstrated a reduction in the Vastus Lateralis activity during incline walking for three participants. Overall, this work investigated the feasibility of several versions of the soft exosuit for gait assistance.
ContributorsSridar, Saivimal (Author) / Zhang, Wenlong (Thesis advisor) / Sugar, Thomas (Committee member) / Lockhart, Thurmon (Committee member) / Arizona State University (Publisher)
Created2020
132176-Thumbnail Image.png
Description
Human walking is a complex and rhythmical activity that comprises of the brain, nerves and muscles. Neuromuscular disorder (NMD) is a broad term that refers to conditions that affect the proper use of muscles and nervous system, thus also impairing the walking or gait cycle of an individual. The improper

Human walking is a complex and rhythmical activity that comprises of the brain, nerves and muscles. Neuromuscular disorder (NMD) is a broad term that refers to conditions that affect the proper use of muscles and nervous system, thus also impairing the walking or gait cycle of an individual. The improper gait cycle might be attributed to the lack of force produced at the toe-off stage. This project addresses if it is possible to create an OpenSim model to find the ideal time and force magnitude needed of an assistive force ankle device to improve gait patterns in individuals with NMD.
ContributorsRivera, Jose Luis (Author) / Zhang, Wenlong (Thesis director) / Lockhart, Thurmon (Committee member) / Harrington Bioengineering Program (Contributor, Contributor) / Barrett, The Honors College (Contributor)
Created2019-05
131377-Thumbnail Image.png
Description
Over the past 30 years the use of graphene has been increasing at a rapid rate. The reason why graphene has become more popular is because it is starting to be understood better, and researchers are starting to recognize graphene’s unique properties. Graphene is a single atomic layer of graphite,

Over the past 30 years the use of graphene has been increasing at a rapid rate. The reason why graphene has become more popular is because it is starting to be understood better, and researchers are starting to recognize graphene’s unique properties. Graphene is a single atomic layer of graphite, and graphite is a three-dimensional cube base structure of carbon. Graphite has a high conductivity rate, and graphene has an even higher conductivity, meaning that graphene makes for an excellent resistor in any hardware system. Graphene is flexible, has high durability, and can vary in resistance based on its shape (Sharon 2015). With graphene being able to change its resistivity, it can act as different types of sensors. These sensors include measuring pressure, resistance, force, strain, and angle. One problem across the globe is that patients have arthritis, decaying bone density, and injuries which can easily go mistreated or not treated at all. It can be hard to determine the severity of injuries in joints by observation of the patient. There are tools and equipment that will allow a doctor to track the force and degrees of motion of certain joints, but they are mostly limited to hospitals. With graphene acting as a sensor it can be embedded into casts, braces, and even clothing. With a mobile sensor that relays accurate and continuous data to a doctor they can more precisely determine a therapy or recovery time that will better suit the patients’ needs. In this project the graphene was used to measure the angle of a patient’s wrist while they were wearing a wrist brace. From the data collected, the graphene was able to track the user’s movement of their wrist as they moved it in a single direction. The data showed the angle of the wrist ranging from zero degrees to 90 degrees. This proves that graphene can shape the way biosensing is accomplished. Biodynamics is a growing field, and with more injuries everyday it is important to study graphene and how it can be used to diagnose and prevent injuries related to joints. Graphene can be used as a biosensor which can then be implemented into a brace to allow for accurate biodynamic tracking.
ContributorsSweeten, William (Author) / Lockhart, Thurmon (Thesis director) / Helms Tillery, Stephen (Committee member) / Harrington Bioengineering Program (Contributor) / Barrett, The Honors College (Contributor)
Created2020-05