Filtering by
- All Subjects: Biomechanics
- Creators: Peterson, Daniel
- Creators: Santello, Marco
- Creators: Artemiadis, Panagiotis
A knee exoskeleton and ankle assistive device (Robotic Shoe) are developed and used to provide walking assistance. The knee exoskeleton provides personalized knee joint assistive torque during the stance phase. The robotic shoe is a light-weighted mechanism that can store the potential energy at heel strike and release it by using an active locking mechanism at the terminal stance phase to provide push-up ankle torque and assist the toe-off. Lower-limb Kinematic time series data are collected for subjects wearing these devices in the passive and active mode. The changes of kinematics with and without these devices on lower-limb motion are first studied. Orbital stability, as one of the commonly used measure to quantify gait stability through calculating Floquet Multipliers (FM), is employed to asses the effects of these wearable devices on gait stability. It is shown that wearing the passive knee exoskeleton causes less orbitally stable gait for users, while the knee joint active assistance improves the orbital stability compared to passive mode. The robotic shoe only affects the targeted joint (right ankle) kinematics, and wearing the passive mechanism significantly increases the ankle joint FM values, which indicates less walking orbital stability. More analysis is done on a mechanically perturbed walking public data set, to show that orbital stability can quantify the effects of external mechanical perturbation on gait dynamic stability. This method can further be used as a control design tool to ensure gait stability for users of lower-limb assistive devices.
dexterous task was analyzed. An eye-tracking device was affixed to subjects during
sequences of null (salient center of mass) and weighted (non salient center of mass) trials
with unconstrained precision grasp. Subjects experienced both expected and unexpected
perturbations, with the task of minimizing object roll. Unexpected perturbations were
controlled by switching weights between trials, expected perturbations were controlled by
asking subjects to rotate the object themselves. In all cases subjects were able to
minimize the roll of the object within three trials. Eye fixations were correlated with
object weight for the initial context and for known shifts in center of mass. In subsequent
trials with unexpected weight shifts, subjects appeared to scan areas of interest from both
contexts even after learning present orientation.
Oscillatory perturbations with varying amplitudes and frequencies have been found to significantly affect human standing balance. However, previous studies have only applied perturbation in either the anterior-posterior (AP) or the medio-lateral (ML) directions. Little is currently known about the impacts of 2D oscillatory perturbations on postural stability, which are more commonly seen in daily life (i.e., while traveling on trains, ships, etc.). This study investigated the effects of applying 2D perturbations vs 1D perturbations on standing stability, and how increasing the frequency and amplitude of perturbation impacts postural stability. A dual-axis robotic platform was utilized to simulate various oscillatory perturbations and evaluate standing postural stability. Fifteen young healthy subjects were recruited to perform quiet stance on the platform. Impacts of perturbation direction (i.e., 1D versus 2D), amplitude, and frequency on postural stability were investigated by analyzing different stability measures, specifically AP/ML/2D Center-of-Pressure (COP) path length, AP/ML/2D Time-to-Boundary (TtB), and sway area. Standing postural stability was compromised more by 2D perturbations than 1D perturbations, evidenced by a significant increase in COP path length and sway area and decrease in TtB. Further, the stability decreased as 2D perturbation amplitude and frequency increased. A significant increase in COP path length and decrease in TtB were consistently observed as the 2D perturbation amplitude and frequency increased. However, sway area showed a considerable increase only with increasing perturbation amplitude but not with increasing frequency.