Matching Items (3)
Filtering by

Clear all filters

Description
The traditional understanding of robotics includes mechanisms of rigid structures, which can manipulate surrounding objects, taking advantage of mechanical actuators such as motors and servomechanisms. Although these methods provide the underlying fundamental concepts behind much of modern technological infrastructure, in fields such as manufacturing, automation, and biomedical application, the robotic

The traditional understanding of robotics includes mechanisms of rigid structures, which can manipulate surrounding objects, taking advantage of mechanical actuators such as motors and servomechanisms. Although these methods provide the underlying fundamental concepts behind much of modern technological infrastructure, in fields such as manufacturing, automation, and biomedical application, the robotic structures formed by rigid axels on mechanical actuators lack the delicate differential sensors and actuators associated with known biological systems. The rigid structures of traditional robotics also inhibit the use of simple mechanisms in congested and/or fragile environments. By observing a variety of biological systems, it is shown that nature models its structures over millions of years of evolution into a combination of soft structures and rigid skeletal interior supports. Through technological bio-inspired designs, researchers hope to mimic some of the complex behaviors of biological mechanisms using pneumatic actuators coupled with highly compliant materials that exhibit relatively large reversible elastic strain. This paper begins the brief history of soft robotics, the various classifications of pneumatic fluid systems, the associated difficulties that arise with the unpredictable nature of fluid reactions, the methods of pneumatic actuators in use today, the current industrial applications of soft robotics, and focuses in large on the construction of a universally adaptable soft robotic gripper and material application tool. The central objective of this experiment is to compatibly pair traditional rigid robotics with the emerging technologies of sort robotic actuators. This will be done by combining a traditional rigid robotic arm with a soft robotic manipulator bladder for the purposes of object manipulation and excavation of extreme environments.
ContributorsShuster, Eden S. (Author) / Thanga, Jekan (Thesis director) / Asphaug, Erik (Committee member) / Mechanical and Aerospace Engineering Program (Contributor) / Barrett, The Honors College (Contributor)
Created2016-05
131408-Thumbnail Image.png
Description
Advancements in the field of design and control of lower extremity robotics requires a comprehensive understanding of the underlying mechanics of the human ankle. The ankle joint acts as an essential interface between the neuromuscular system of the body and the physical world, especially during locomotion. This paper investigates how

Advancements in the field of design and control of lower extremity robotics requires a comprehensive understanding of the underlying mechanics of the human ankle. The ankle joint acts as an essential interface between the neuromuscular system of the body and the physical world, especially during locomotion. This paper investigates how the modulation of ankle stiffness is altered throughout the stance phase of the gait cycle depending on the environment the ankle is interacting with. Ten young healthy subjects with no neurological impairments or history of ankle injury were tested by walking over a robotic platform which collected torque and position data. The platform performed a perturbation on the ankle at 20%, 40%, and 60% of their stance phase in order to estimate ankle stiffness and evaluate if the environment plays a role on its modulation. The platform provided either a rigid environment or a compliant environment in which it was compliant and deflected according to the torque applied to the platform. Subjects adapted in different ways to achieve balance in the different environments. When comparing the environments, subjects modulated their stiffness to either increase, decrease, or remain the same. Notably, stiffness as well as the subjects’ center of pressure was found to increase with time as they transitioned from late loading to terminal stance (heel strike to toe-off) regardless of environmental conditions. This allowed for a model of ankle stiffness to be developed as a function of center of pressure, independent of whether a subject is walking on the rigid or compliant environment. The modulation of stiffness parameters characterized in this study can be used in the design and control of lower extremity robotics which focus on accurate biomimicry of the healthy human ankle. The stiffness characteristics can also be used to help identify particular ankle impairments and to design proper treatment for individuals such as those who have suffered from a stroke or MS. Changing environments is where a majority of tripping incidents occur, which can lead to significant injuries. For this reason, studying healthy ankle behavior in a variety of environments is of particular interest.
ContributorsBliss, Clayton F (Author) / Lee, Hyunglae (Thesis director) / Marvi, Hamid (Committee member) / Mechanical and Aerospace Engineering Program (Contributor) / Barrett, The Honors College (Contributor)
Created2020-05
Description

The concept of entrainment broadly applies the locking of phases between 2 independent systems [17]. This physical phenomenon can be applied to modify neuromuscular movement in humans during bipedal locomotion. Gait entrainment to robotic devices have shown great success as alternatives to labor intensive methods of rehabilitation. By applying additional

The concept of entrainment broadly applies the locking of phases between 2 independent systems [17]. This physical phenomenon can be applied to modify neuromuscular movement in humans during bipedal locomotion. Gait entrainment to robotic devices have shown great success as alternatives to labor intensive methods of rehabilitation. By applying additional torque at the ankle joint, previous studies have exhibited consistent gait entrainment to both rigid and soft robotic devices. This entrainment is characterized by consistent phase locking of plantarflexion perturbations to the ‘push off’ event within the gait cycle. However, it is unclear whether such phase locking can be attributed to the plantarflexion assistance from the device or the sensory stimulus of movement at the ankle. To clarify the mechanism of entrainment, an experiment was designed to expose the user to a multitude of varying torques applied at the ankle to assist with plantar flexion. In this experiment, no significant difference in success of subject entrainment occurred when additional torque applied was greater than a detectable level. Force applied at the ankle varied from ~60N to ~130N. This resulted in successful entrainment ~88\% of the time at 98 N, with little to no increase in success as force increased thereafter. Alternatively, success of trials decreased significantly as force was reduced below this level, causing the perturbations to become undetectable by participants. Ultimately this suggests that higher levels of actuator pressure, and thus greater levels of torque applied to the foot, do not increase the likelihood of entrainment during walking. Rather, the results of this study suggest that proper detectable sensory stimulus is the true mechanism for entrainment.

ContributorsKruse, Anna (Author) / Lee, Hyunglae (Thesis director) / Berman, Spring (Committee member) / Barrett, The Honors College (Contributor) / Mechanical and Aerospace Engineering Program (Contributor)
Created2022-12