Filtering by
- All Subjects: Neuroscience
- All Subjects: Soft actuator
- Creators: Harrington Bioengineering Program
- Member of: Theses and Dissertations
commands designed to streamline post-processing of MRI images. Using this partnership, the Applied Neuroscience and Technology Lab at PCH has been able to complete production of a post-processing pipeline which integrates locally sourced smoothing techniques to help identify lesions in patients with evidence of Focal Cortical Dysplasia. The end result is a system in which a patient with epilepsy may experience more successful post-surgical results due to the
combination of a lesion detection mechanism and the radiologist using their trained eye in the presurgical stages. As one of the main points of this work is the global aspect of it, Barrett thesis funding was dedicated for a trip to London in order to network with other MELD project collaborators. This was a successful trip for the project as a whole in addition to this particular thesis. The ability to troubleshoot problems with one another in a room full of subject matter
experts allowed for a high level of discussion and learning. Future work includes implementing machine learning approaches which consider all morphometry parameters simultaneously.
Advancing the understanding and treatment of many neurological disorders can be achieved by improving methods of neuronal detection at increased depth in the mammalian brain. Different cell subtypes cannot be detected using non-invasive techniques beyond 1 mm from cortical surface, in the context of targeting particular cell types in vivo (Wang, 2012). These limitations in the depth of imaging and targeting are due to optical scattering (Ntziachristos, 2010). In order to overcome these restrictions, longer wavelength fluorescent proteins have been utilized by researchers to see tagged cells at depth. Optical techniques such as two-photon and confocal microscopy have been used in combination with fluorescent proteins to expand depth, but are still limited by the penetration depth of light due to optical scattering (Lee, 2015). This research aims to build on other detection methods, such as the photoacoustic effect and automated fluorescence-guided electrophysiology, to overcome this limitation.
Falls are known to be a common occurrence and a costly one as well, as they are the second leading cause of unintentional deaths and millions of other injuries worldwide. Falls often occur due to an increase in trunk flexion angle, so this experiment aims to reduce the trunk flexion received while stepping over an obstacle. To achieve this a soft actuator was attached to the trunk and pressure was sent as subjects walked and stepped over an obstacle presented on a treadmill. The pressure is meant to stiffen the back which should in theory reduce the trunk flexion angle and lower the chances of falling. In this experiment, two groups were tested: three participants from a control group (healthy young adults) and three participants from an experimental group (healthy elderly adults). Since elderly adults have the highest fall risk due to overall lack of stability, they are the experimental group and the focus for this experiment. The results from the study showed that elderly adults had a beneficial effect with the soft actuator as there was a noticeable difference in trunk flexion when the device was attached. The experiment also supported prior research that stated that trunk flexion was greater in elderly adults than younger adults. Despite the positive results, further studies should be done to prove that the soft devices influence lowering trunk flexion angle as well as to see if the device has any noticeable effect on younger adults.