Matching Items (2)
153868-Thumbnail Image.png
Description
The need for rapid, specific and sensitive assays that provide a detection of bacterial indicators are important for monitoring water quality. Rapid detection using biosensor is a novel approach for microbiological testing applications. Besides, validation of rapid methods is an obstacle in adoption of such new bio-sensing technologies.

The need for rapid, specific and sensitive assays that provide a detection of bacterial indicators are important for monitoring water quality. Rapid detection using biosensor is a novel approach for microbiological testing applications. Besides, validation of rapid methods is an obstacle in adoption of such new bio-sensing technologies. In this study, the strategy developed is based on using the compound 4-methylumbelliferyl glucuronide (MUG), which is hydrolyzed rapidly by the action of E. coli β-D-glucuronidase (GUD) enzyme to yield a fluorogenic product that can be quantified and directly related to the number of E. coli cells present in water samples. The detection time required for the biosensor response ranged from 30 to 120 minutes, depending on the number of bacteria. The specificity of the MUG based biosensor platform assay for the detection of E. coli was examined by pure cultures of non-target bacterial genera and also non-target substrates. GUD activity was found to be specific for E. coli and no such enzymatic activity was detected in other species. Moreover, the sensitivity of rapid enzymatic assays was investigated and repeatedly determined to be less than 10 E. coli cells per reaction vial concentrated from 100 mL of water samples. The applicability of the method was tested by performing fluorescence assays under pure and mixed bacterial flora in environmental samples. In addition, the procedural QA/QC for routine monitoring of drinking water samples have been validated by comparing the performance of the biosensor platform for the detection of E. coli and culture-based standard techniques such as Membrane Filtration (MF). The results of this study indicated that the fluorescence signals generated in samples using specific substrate molecules can be utilized to develop a bio-sensing platform for the detection of E. coli in drinking water. The procedural QA/QC of the biosensor will provide both industry and regulatory authorities a useful tool for near real-time monitoring of E. coli in drinking water samples. Furthermore, this system can be applied independently or in conjunction with other methods as a part of an array of biochemical assays in order to reliably detect E. coli in water.
ContributorsHesari, Nikou (Author) / Abbaszadegan, Morteza (Thesis advisor) / Alum, Absar (Committee member) / Fox, Peter (Committee member) / Stout, Valerie (Committee member) / Arizona State University (Publisher)
Created2015
156917-Thumbnail Image.png
Description
Radioactive cesium (137Cs), released from nuclear power plants and nuclear accidental releases, is a problem due to difficulties regarding its removal. Efforts have been focused on removing cesium and the remediation of the contaminated environment. Traditional treatment techniques include Prussian blue and nano zero-valent ion (nZVI) and nano-Fe/Cu particles to

Radioactive cesium (137Cs), released from nuclear power plants and nuclear accidental releases, is a problem due to difficulties regarding its removal. Efforts have been focused on removing cesium and the remediation of the contaminated environment. Traditional treatment techniques include Prussian blue and nano zero-valent ion (nZVI) and nano-Fe/Cu particles to remove Cs from water; however, they are not efficient at removing Cs when present at low concentrations of about 10 parts-per-billion (ppb), typical of concentrations found in the radioactive contaminated sites.

The objective of this study was to develop an innovative and simple method to remove Cs+ present at low concentrations by engineering a proteoliposome transporter composed of an uptake protein reconstituted into a liposome vesicle. To achieve this, the uptake protein, Kup, from E. coli, was isolated through protein extraction and purification procedures. The new and simple extraction methodology developed in this study was highly efficient and resulted in purified Kup at ~1 mg/mL. A new method was also developed to insert purified Kup protein into the bilayers of liposome vesicles. Finally, removal of CsCl (10 and 100 ppb) was demonstrated by spiking the constructed proteoliposome in lab-fortified water, followed by incubation and ultracentrifugation, and measuring Cs+ with inductively coupled plasma mass spectrometry (ICP-MS).

The ICP-MS results from testing water contaminated with 100 ppb CsCl, revealed that adding 0.1 – 8 mL of Kup proteoliposome resulted in 0.29 – 12.7% Cs removal. Addition of 0.1 – 2 mL of proteoliposome to water contaminated with 10 ppb CsCl resulted in 0.65 – 3.43% Cs removal. These removal efficiencies were greater than the control, liposome with no protein.

A linear relationship was observed between the amount of proteoliposome added to the contaminated water and removal percentage. Consequently, by adding more volumes of proteoliposome, removal can be simply improved. This suggests that with ~ 60-70 mL of proteoliposome, removal of about 90% can be achieved. The novel technique developed herein is a contribution to emerging technologies in the water and wastewater treatment industry.
ContributorsHakim Elahi, Sepideh (Author) / Conroy-Ben, Otakuye (Thesis advisor) / Abbaszadegan, Morteza (Committee member) / Fox, Peter (Committee member) / Arizona State University (Publisher)
Created2018