Matching Items (9)
Filtering by

Clear all filters

152146-Thumbnail Image.png
Description
Human breath is a concoction of thousands of compounds having in it a breath-print of physiological processes in the body. Though breath provides a non-invasive and easy to handle biological fluid, its analysis for clinical diagnosis is not very common. Partly the reason for this absence is unavailability of cost

Human breath is a concoction of thousands of compounds having in it a breath-print of physiological processes in the body. Though breath provides a non-invasive and easy to handle biological fluid, its analysis for clinical diagnosis is not very common. Partly the reason for this absence is unavailability of cost effective and convenient tools for such analysis. Scientific literature is full of novel sensor ideas but it is challenging to develop a working device, which are few. These challenges include trace level detection, presence of hundreds of interfering compounds, excessive humidity, different sampling regulations and personal variability. To meet these challenges as well as deliver a low cost solution, optical sensors based on specific colorimetric chemical reactions on mesoporous membranes have been developed. Sensor hardware utilizing cost effective and ubiquitously available light source (LED) and detector (webcam/photo diodes) has been developed and optimized for sensitive detection. Sample conditioning mouthpiece suitable for portable sensors is developed and integrated. The sensors are capable of communication with mobile phones realizing the idea of m-health for easy personal health monitoring in free living conditions. Nitric oxide and Acetone are chosen as analytes of interest. Nitric oxide levels in the breath correlate with lung inflammation which makes it useful for asthma management. Acetone levels increase during ketosis resulting from fat metabolism in the body. Monitoring breath acetone thus provides useful information to people with type1 diabetes, epileptic children on ketogenic diets and people following fitness plans for weight loss.
ContributorsPrabhakar, Amlendu (Author) / Tao, Nongjian (Thesis advisor) / Forzani, Erica (Committee member) / Lindsay, Stuart (Committee member) / Arizona State University (Publisher)
Created2013
Description
Obtaining local electrochemical (EC) information is extremely important for understanding basic surface reactions, and for many applications. Scanning electrochemical microscopy (SECM) can obtain local EC information by scanning a microelectrode across the surface. Although powerful, SECM is slow, the scanning microelectrode may perturb reaction and the measured signal decreases with

Obtaining local electrochemical (EC) information is extremely important for understanding basic surface reactions, and for many applications. Scanning electrochemical microscopy (SECM) can obtain local EC information by scanning a microelectrode across the surface. Although powerful, SECM is slow, the scanning microelectrode may perturb reaction and the measured signal decreases with the size of microelectrode. This thesis demonstrates a new imaging technique based on a principle that is completely different from the conventional EC detection technologies. The technique, referred to as plasmonic-based electrochemical imaging (PECI), images local EC current (both faradaic and non-faradaic) without using a scanning microelectrode. Because PECI response is an optical signal originated from surface plasmon resonance (SPR), PECI is fast and non-invasive and its signal is proportional to incident light intensity, thus does not decrease with the area of interest. A complete theory is developed in this thesis work to describe the relationship between EC current and PECI signal. EC current imaging at various fixed potentials and local cyclic voltammetry methods are developed and demonstrated with real samples. Fast imaging rate (up to 100,000 frames per second) with 0.2×3µm spatial resolution and 0.3 pA detection limit have been achieved. Several PECI applications have been developed to demonstrate the unique strengths of the new imaging technology. For example, trace particles in fingerprint is detected by PECI, a capability that cannot be achieved with the conventional EC technologies. Another example is PECI imaging of EC reaction and interfacial impedance of graphene of different thicknesses. In addition, local square wave voltammetry capability is demonstrated and applied to study local catalytic current of platinum nanoparticle microarray. This thesis also describes a related but different research project that develops a new method to measure surface charge densities of SPR sensor chips, and micro- and nano-particles. A third project of this thesis is to develop a method to expand the conventional SPR detection and imaging technology by including a waveguide mode. This innovation creates a sensitive detection of bulk index of refraction, which overcomes the limitation that the conventional SPR can probe only changes near the sensor surface within ~200 nm.
ContributorsShan, Xiaonan (Author) / Tao, Nongjian (Thesis advisor) / Chae, Junseok (Committee member) / Christen, Jennifer Blain (Committee member) / Hayes, Mark (Committee member) / Arizona State University (Publisher)
Created2011
150984-Thumbnail Image.png
Description
Single molecules in a tunnel junction can now be interrogated reliably using chemically-functionalized electrodes. Monitoring stochastic bonding fluctuations between a ligand bound to one electrode and its target bound to a second electrode ("tethered molecule-pair" configuration) gives insight into the nature of the intermolecular bonding at a single molecule-pair level,

Single molecules in a tunnel junction can now be interrogated reliably using chemically-functionalized electrodes. Monitoring stochastic bonding fluctuations between a ligand bound to one electrode and its target bound to a second electrode ("tethered molecule-pair" configuration) gives insight into the nature of the intermolecular bonding at a single molecule-pair level, and defines the requirements for reproducible tunneling data. Importantly, at large tunnel gaps, there exists a regime for many molecules in which the tunneling is influenced more by the chemical identity of the molecules than by variability in the molecule-metal contact. Functionalizing a pair of electrodes with recognition reagents (the "free analyte" configuration) can generate a distinct tunneling signal when an analyte molecule is trapped in the gap. This opens up a new interface between chemistry and electronics with immediate implications for rapid sequencing of single DNA molecules.
ContributorsChang, Shuai (Author) / Lindsay, Stuart (Thesis advisor) / Ros, Robert (Committee member) / Zhang, Peiming (Committee member) / Tao, Nongjian (Committee member) / Shumway, John (Committee member) / Arizona State University (Publisher)
Created2012
151211-Thumbnail Image.png
Description
CpG methylation is an essential requirement for the normal development of mammals, but aberrant changes in the methylation can lead to tumor progression and cancer. An in-depth understanding of this phenomenon can provide insights into the mechanism of gene repression. We present a study comparing methylated DNA and normal DNA

CpG methylation is an essential requirement for the normal development of mammals, but aberrant changes in the methylation can lead to tumor progression and cancer. An in-depth understanding of this phenomenon can provide insights into the mechanism of gene repression. We present a study comparing methylated DNA and normal DNA wrt its persistence length and contour length. Although, previous experiments and studies show no difference between the physical properties of the two, the data collected and interpreted here gives a different picture to the methylation phenomena and its effect on gene silencing. The study was extended to the artificially reconstituted chromatin and its interactions with the methyl CpG binding proteins were also probed.
ContributorsKaur, Parminder (Author) / Lindsay, Stuart (Thesis advisor) / Ros, Robert (Committee member) / Tao, Nongjian (Committee member) / Vaiana, Sara (Committee member) / Beckenstein, Oliver (Committee member) / Arizona State University (Publisher)
Created2012
154543-Thumbnail Image.png
Description
Volcanic devolatilization is one of the major processes in the global nitrogen cycle. Past studies have often estimated the magnitude of this flux using volcanic emission measurements, which are limited to currently active systems and sensitive to atmospheric contamination. A different methodological approach requires appropriate analytical parameters for nitrogen analysis

Volcanic devolatilization is one of the major processes in the global nitrogen cycle. Past studies have often estimated the magnitude of this flux using volcanic emission measurements, which are limited to currently active systems and sensitive to atmospheric contamination. A different methodological approach requires appropriate analytical parameters for nitrogen analysis in silicate glasses by secondary ion mass spectrometry (SIMS), which have not yet been established. To this end, we analyze various ion implanted basaltic and rhyolitic glasses by SIMS. We demonstrate that water content significantly affects the ion yields of 14N+ and 14N16O−, as well as the background intensity of 14N+ and 12C+. Application of implant-derived calibrations to natural samples provide the first reported concentrations of nitrogen in melt inclusions. These measurements are from samples from the Bishop Tuff in California, the Huckleberry Ridge Tuff of the Yellowstone Volcanic Center, and material from the Okaia and Oruanui eruptions in the Taupo Volcanic Center. In all studied material, we find maximum nitrogen contents of less than 45 ppm and that nitrogen concentration varies positively with CO2 concentration, which is interpreted to reflect partial degassing trend. Using the maximum measured nitrogen contents for each eruption, we find that the Bishop released >3.6 x 1013 g of nitrogen, the Huckleberry Ridge released >1.3 x 1014 g, the Okaia released >1.1 x 1011 g of nitrogen, the Oruanui released >4.7 x 1013 g of nitrogen. Simple calculations suggest that with concentrations such as these, rhyolitic eruptions may ephemerally increase the nitrogen flux to the atmosphere, but are insignificant compared to the 4 x 1021 g of nitrogen stored in the atmosphere.
ContributorsRegier, Margo Elaine (Author) / Hervig, Richard L (Thesis advisor) / Roggensack, Kurt (Committee member) / Till, Christy B. (Committee member) / Arizona State University (Publisher)
Created2016
154306-Thumbnail Image.png
Description
Charge transport in molecular systems, including DNA (Deoxyribonucleic acid), is involved in many basic chemical and biological processes. Studying their charge transport properties can help developing DNA based electronic devices with many tunable functionalities. This thesis investigates the electric properties of double-stranded DNA, DNA G-quadruplex and dsDNA with modified base.

First,

Charge transport in molecular systems, including DNA (Deoxyribonucleic acid), is involved in many basic chemical and biological processes. Studying their charge transport properties can help developing DNA based electronic devices with many tunable functionalities. This thesis investigates the electric properties of double-stranded DNA, DNA G-quadruplex and dsDNA with modified base.

First, double-stranded DNA with alternating GC sequence and stacked GC sequence were measured with respect to length. The resistance of DNA sequences increases linearly with length, indicating a hopping transport mechanism. However, for DNA sequences with stacked GC, a periodic oscillation is superimposed on the linear length dependence, indicating a partial coherent transport. The result is supported by the finding of delocalization of the highest occupied molecular orbitals of Guanines from theoretical simulation and by fitting based on the Büttiker’s theory.

Then, a DNA G4-duplex structures with a G-quadruplex as the core and DNA duplexes as the arms were studied. Similar conductance values were observed by varying the linker positions, thus a charge splitter is developed. The conductance of the DNA G-tetrads structures was found to be sensitive to the π-stacking at the interface between the G-quadruplex and DNA duplexes by observing a higher conductance value when one duplex was removed and a polyethylene glycol (PEG) linker was added into the interface. This was further supported by molecular dynamic simulations.

Finally, a double-stranded DNA with one of the bases replaced by an anthraquinone group was studied via electrochemical STM break junction technique. Anthraquinone can be reversibly switched into the oxidized state or reduced state, to give a low conductance or high conductance respectively. Furthermore, the thermodynamics and kinetics properties of the switching were systematically studied. Theoretical simulation shows that the difference between the two states is due to a difference in the energy alignment with neighboring Guanine bases.
ContributorsXiang, Liming (Author) / Tao, Nongjian (Thesis advisor) / Lindsay, Stuart (Committee member) / Gould, Ian (Committee member) / Arizona State University (Publisher)
Created2016
155525-Thumbnail Image.png
Description
Studying charge transport through single molecules is of great importance for unravelling charge transport mechanisms, investigating fundamentals of chemistry, and developing functional building blocks in molecular electronics.

First, a study of the thermoelectric effect in single DNA molecules is reported. By varying the molecular length and sequence, the charge transport in

Studying charge transport through single molecules is of great importance for unravelling charge transport mechanisms, investigating fundamentals of chemistry, and developing functional building blocks in molecular electronics.

First, a study of the thermoelectric effect in single DNA molecules is reported. By varying the molecular length and sequence, the charge transport in DNA was tuned to either a hopping- or tunneling-dominated regimes. In the hopping regime, the thermoelectric effect is small and insensitive to the molecular length. Meanwhile, in the tunneling regime, the thermoelectric effect is large and sensitive to the length. These findings indicate that by varying its sequence and length, the thermoelectric effect in DNA can be controlled. The experimental results are then described in terms of hopping and tunneling charge transport models.

Then, I showed that the electron transfer reaction of a single ferrocene molecule can be controlled with a mechanical force. I monitor the redox state of the molecule from its characteristic conductance, detect the switching events of the molecule from reduced to oxidized states with the force, and determine a negative shift of ~34 mV in the redox potential under force. The theoretical modeling is in good agreement with the observations, and reveals the role of the coupling between the electronic states and structure of the molecule.

Finally, conclusions and perspectives were discussed to point out the implications of the above works and future studies that can be performed based on the findings.
ContributorsLi, Yueqi, Ph.D (Author) / Tao, Nongjian (Thesis advisor) / Buttry, Daniel (Committee member) / Mujica, Vladimiro (Committee member) / Arizona State University (Publisher)
Created2017
157941-Thumbnail Image.png
Description
Air pollution has been linked to various health problems but how different air pollutants and exposure levels contribute to those diseases remain largely unknown. Researchers have mainly relied on data from government air monitoring stations to study the health effects of air pollution exposure. The limited information provided by sparse

Air pollution has been linked to various health problems but how different air pollutants and exposure levels contribute to those diseases remain largely unknown. Researchers have mainly relied on data from government air monitoring stations to study the health effects of air pollution exposure. The limited information provided by sparse stations has low spatial and temporal resolution, which is not able to represent the actual exposure of individuals. A tool that can accurately monitor personal exposure provides valuable data for epidemiologists to understand the relationship between air pollution and certain diseases. It also allows individuals to be aware of any ambient air quality issues and prevent air pollution exposure. To build such a tool, sensors with features of fast response, small size, long lifetime, high sensitivity, high selectivity, and multi-analyte sensing are of great importance.

In order to meet these requirements, three generations of novel colorimetric sensors have been developed. The first generation is mosaic colorimetric sensors based on tiny sensor blocks and by detecting absorbance change after each air sample injection, the target analyte concentration can be measured. The second generation is a gradient-based colorimetric sensor. Lateral transport of analytes across the colorimetric sensor surface creates a color gradient that shifts along the transport direction over time, and the sensor tracks the gradient shift and converts it into analyte concentration in real-time. The third generation is gradient-based colorimetric arrays fabricated by inkjet-printing method that integrates multiple sensors on a miniaturized sensor chip. Unlike traditional colorimetric sensors, such as detection tubes and optoelectronic nose, that are typically for one-time use, the presented three generations of colorimetric sensors aim to continuously monitor multiple air pollutants and the sensor lifetime and fabrication methods have been improved over each generation. Ozone, nitrogen dioxide, formaldehyde and carbon monoxide are chosen as analytes of interest. The performance of sensors has been validated in the lab and field tests, proving the capability of the sensors to be used for personal exposure monitoring.
ContributorsLin, Chenwen (Author) / Tao, Nongjian (Thesis advisor) / Borges, Chad R (Committee member) / Hayes, Mark A. (Committee member) / Arizona State University (Publisher)
Created2019
161897-Thumbnail Image.png
Description
A novel technique for measuring heavy trace elements in geologic materials with secondary ion mass spectrometry (SIMS) is presented. This technique combines moderate levels of mass resolving power (MRP) with energy filtering in order to remove molecular ion interferences while maintaining enough sensitivity to measure trace elements. The technique was

A novel technique for measuring heavy trace elements in geologic materials with secondary ion mass spectrometry (SIMS) is presented. This technique combines moderate levels of mass resolving power (MRP) with energy filtering in order to remove molecular ion interferences while maintaining enough sensitivity to measure trace elements. The technique was evaluated by measuring a set of heavy chalcophilic elements in two sets of doped glasses similar in composition to rhyolites and basalts, respectively. The normalized count rates of Cu, As, Se, Br, and Te were plotted against concentrations to test that the signal increased linearly with concentration. The signal from any residual molecular ion interferences (e.g. ²⁹Si³⁰Si¹⁶O on ⁷⁵As) represented apparent concentrations ≤ 1 μg/g for most of the chalcophiles in rhyolitic matrices and between 1 and 10 μg/g in basaltic compositions. This technique was then applied to two suites of melt inclusions from the Bandelier Tuff: Ti-rich, primitive and Ti-poor, evolved rhyolitic compositions. The results showed that Ti-rich inclusions contained ~30 μg/g Cu and ~3 μg/g As while the Ti-poor inclusions contained near background Cu and ~6 μg/g As. Additionally, two of the Ti-rich inclusions contained > 5 μg/g of Sb and Te, well above background. Other elements were at or near background. This suggests certain chalcophilic elements may be helpful in unraveling processes relating to diversity of magma sources in large eruptions. Additionally, an unrelated experiment is presented demonstrating changes in the matrix effect on SIMS counts when normalizing against ³⁰Si⁺ versus ²⁸Si²⁺. If one uses doubly charged silicon as a reference, (common when using large-geometry SIMS instruments to study the light elements Li - C) it is important that the standards closely match the major element chemistry of the unknown.
ContributorsCarlson, Eric Norton (Author) / Hervig, Richard L (Thesis advisor) / Roggensack, Kurt (Committee member) / Burt, Donald M (Committee member) / Arizona State University (Publisher)
Created2021