Matching Items (6)
Filtering by

Clear all filters

151088-Thumbnail Image.png
Description
Approximately 1.7 million people in the United States are living with limb loss and are in need of more sophisticated devices that better mimic human function. In the Human Machine Integration Laboratory, a powered, transtibial prosthetic ankle was designed and build that allows a person to regain ankle function with

Approximately 1.7 million people in the United States are living with limb loss and are in need of more sophisticated devices that better mimic human function. In the Human Machine Integration Laboratory, a powered, transtibial prosthetic ankle was designed and build that allows a person to regain ankle function with improved ankle kinematics and kinetics. The ankle allows a person to walk normally and up and down stairs, but volitional control is still an issue. This research tackled the problem of giving the user more control over the prosthetic ankle using a force/torque circuit. When the user presses against a force/torque sensor located inside the socket the prosthetic foot plantar flexes or moves downward. This will help the user add additional push-off force when walking up slopes or stairs. It also gives the user a sense of control over the device.
ContributorsFronczyk, Adam (Author) / Sugar, Thomas G. (Thesis advisor) / Helms-Tillery, Stephen (Thesis advisor) / Santello, Marco (Committee member) / Arizona State University (Publisher)
Created2012
156964-Thumbnail Image.png
Description
Proprioception is the sense of body position, movement, force, and effort. Loss of proprioception can affect planning and control of limb and body movements, negatively impacting activities of daily living and quality of life. Assessments employing planar robots have shown that proprioceptive sensitivity is directionally dependent within the horizontal plane

Proprioception is the sense of body position, movement, force, and effort. Loss of proprioception can affect planning and control of limb and body movements, negatively impacting activities of daily living and quality of life. Assessments employing planar robots have shown that proprioceptive sensitivity is directionally dependent within the horizontal plane however, few studies have looked at proprioceptive sensitivity in 3d space. In addition, the extent to which proprioceptive sensitivity is modifiable by factors such as exogenous neuromodulation is unclear. To investigate proprioceptive sensitivity in 3d we developed a novel experimental paradigm employing a 7-DoF robot arm, which enables reliable testing of arm proprioception along arbitrary paths in 3d space, including vertical motion which has previously been neglected. A participant’s right arm was coupled to a trough held by the robot that stabilized the wrist and forearm, allowing for changes in configuration only at the elbow and shoulder. Sensitivity to imposed displacements of the endpoint of the arm were evaluated using a “same/different” task, where participant’s hands were moved 1-4 cm from a previously visited reference position. A measure of sensitivity (d’) was compared across 6 movement directions and between 2 postures. For all directions, sensitivity increased monotonically as the distance from the reference location increased. Sensitivity was also shown to be anisotropic (directionally dependent) which has implications for our understanding of the planning and control of reaching movements in 3d space.

The effect of neuromodulation on proprioceptive sensitivity was assessed using transcutaneous electrical nerve stimulation (TENS), which has been shown to have beneficial effects on human cognitive and sensorimotor performance in other contexts. In this pilot study the effects of two frequencies (30hz and 300hz) and three electrode configurations were examined. No effect of electrode configuration was found, however sensitivity with 30hz stimulation was significantly lower than with 300hz stimulation (which was similar to sensitivity without stimulation). Although TENS was shown to modulate proprioceptive sensitivity, additional experiments are required to determine if TENS can produce enhancement rather than depression of sensitivity which would have positive implications for rehabilitation of proprioceptive deficits arising from stroke and other disorders.
ContributorsKlein, Joshua (Author) / Buneo, Christopher (Thesis advisor) / Helms-Tillery, Stephen (Committee member) / Kleim, Jeffrey (Committee member) / Santello, Marco (Committee member) / Arizona State University (Publisher)
Created2018
154617-Thumbnail Image.png
Description
Humans constantly rely on a complex interaction of a variety of sensory modalities in order to complete even the simplest of daily tasks. For reaching and grasping to interact with objects, the visual, tactile, and proprioceptive senses provide the majority of the information used. While vision is often relied on

Humans constantly rely on a complex interaction of a variety of sensory modalities in order to complete even the simplest of daily tasks. For reaching and grasping to interact with objects, the visual, tactile, and proprioceptive senses provide the majority of the information used. While vision is often relied on for many tasks, most people are able to accomplish common daily rituals without constant visual attention, instead relying mainly on tactile and proprioceptive cues. However, amputees using prosthetic arms do not have access to these cues, making tasks impossible without vision. Even tasks with vision can be incredibly difficult as prosthesis users are unable to modify grip force using touch, and thus tend to grip objects excessively hard to make sure they don’t slip.

Methods such as vibratory sensory substitution have shown promise for providing prosthesis users with a sense of contact and have proved helpful in completing motor tasks. In this thesis, two experiments were conducted to determine whether vibratory cues could be useful in discriminating between sizes. In the first experiment, subjects were asked to grasp a series of hidden virtual blocks of varying sizes with vibrations on the fingertips as indication of contact and compare the size of consecutive boxes. Vibratory haptic feedback significantly increased the accuracy of size discrimination over objects with only visual indication of contact, though accuracy was not as great as for typical grasping tasks with physical blocks. In the second, subjects were asked to adjust their virtual finger position around a series of virtual boxes with vibratory feedback on the fingertips using either finger movement or EMG. It was found that EMG control allowed for significantly less accuracy in size discrimination, implying that, while proprioceptive feedback alone is not enough to determine size, direct kinesthetic information about finger position is still needed.
ContributorsOlson, Markey (Author) / Helms-Tillery, Stephen (Thesis advisor) / Buneo, Christopher (Committee member) / Santello, Marco (Committee member) / Arizona State University (Publisher)
Created2016
189324-Thumbnail Image.png
Description
A current thrust in neurorehabilitation research involves exogenous neuromodulation of peripheral nerves to enhance neuroplasticity and maximize recovery of function. This dissertation presents the results of four experiments aimed at assessing the effects of trigeminal nerve stimulation (TNS) and occipital nerve stimulation (ONS) on motor learning, which was behaviorally characterized

A current thrust in neurorehabilitation research involves exogenous neuromodulation of peripheral nerves to enhance neuroplasticity and maximize recovery of function. This dissertation presents the results of four experiments aimed at assessing the effects of trigeminal nerve stimulation (TNS) and occipital nerve stimulation (ONS) on motor learning, which was behaviorally characterized using an upper extremity visuomotor adaptation paradigm. In Aim 1a, the effects of offline TNS using clinically tested frequencies (120 and 60 Hz) were characterized. Sixty-three participants (22.75±4.6 y/o), performed a visuomotor rotation task and received TNS before encountering rotation of hand visual feedback. In Aim 1b, TNS at 3 kHz, which has been shown to be more tolerable at higher current intensities, was evaluated in 42 additional subjects (23.4±4.6 y/o). Results indicated that 3 kHz stimulation accelerated learning while 60 Hz stimulation slowed learning, suggesting a frequency-dependent effect on learning. In Aim 2, the effect of online TNS using 120 and 60 Hz were characterized to determine if this protocol would deliver better outcomes. Sixty-three participants (23.2±3.9 y/o) received either TNS or sham concurrently with perturbed visual feedback. Results showed no significant differences among groups. However, a cross-study comparison of results obtained with 60 Hz offline TNS showed a statistically significant improvement in learning rates with online stimulation relative to offline, suggesting a timing-dependent effect on learning. In Aim 3, TNS and ONS were compared using the best protocol from previous aims (offline 3 kHz). Additionally, concurrent stimulation of both nerves was explored to look for potential synergistic effects. Eighty-four participants (22.9±3.2 y/o) were assigned to one of four groups: TNS, ONS, TNS+ONS, and sham. Visual inspection of learning curves revealed that the ONS group demonstrated the fastest learning among groups. However, statistical analyses did not confirm this observation. In addition, the TNS+ONS group appeared to learn faster than the sham and TNS groups but slower than the ONS only group, suggesting no synergistic effects using this protocol, as initially hypothesized. The results provide new information on the potential use of TNS and ONS in neurorehabilitation and performance enhancement in the motor domain.
ContributorsArias, Diego (Author) / Buneo, Christopher (Thesis advisor) / Schaefer, Sydney (Committee member) / Helms-Tillery, Stephen (Committee member) / Santello, Marco (Committee member) / Kleim, Jeffrey (Committee member) / Arizona State University (Publisher)
Created2023
187363-Thumbnail Image.png
Description
Finite element models (FEMs) of spine segments validated in their intact states are often used to make predictions following structural modifications simulating surgical procedures, including posterior fusion with pedicle screws and rods (PSR) and laminectomy (removal of posterior column bone to decompress the spinal cord). The gold standard for spine

Finite element models (FEMs) of spine segments validated in their intact states are often used to make predictions following structural modifications simulating surgical procedures, including posterior fusion with pedicle screws and rods (PSR) and laminectomy (removal of posterior column bone to decompress the spinal cord). The gold standard for spine FEM validation compares predicted vs. experimental intervertebral ranges of motion (ROM). Given that muscle co-contraction compresses the spine, validation that considers compression may produce a more robust FEM. One research goal was to evaluate an experimental method of compressing a lumbar spine segment through its sagittal plane balance (pivot) point (BP) using a 6DOF robotic test system. Experimental data supported the hypothesis that structural modifications, such as PSR and laminectomy alter the segment’s BP location and its compressive stiffness. However, evaluation showed that the experimental BP method is sensitive to specimen posture in the robotic test frame; slight flexion or extension produced shear loads during compression that affect BP location and should be included in specimen-specific FEMs to ensure similar load conditions. Another goal was to develop a uniquely calibrated specimen-specific FEM of an intact L4-5 motion segment using the experimental BP data. A specimen-specific FEM was created and calibrated using experimental BP compressive stiffness data, however matching experimental BP location data was unsuccessful. The BP-compression calibrated FEM was evaluated by comparing predicted responses to loads following simulated PSR and laminectomy to specimen-specific experimental data. Predictions using the BP-calibrated and ROM-calibrated FEMs were compared. The BP-calibration process helped identify an unrealistic FEM disc geometry (nucleus pulposus size and location). Both BP-compression and ROM-calibrated FEMs predicted effects of PSR on stiffness (compressive and flexural) that were greater than experimental, which helped identify a problem with simplified representations of bone in the posterior column and at the anterior column interface. The BP-compression calibrated FEMs predicted relative shifts in BP locations and bone surface strains during compression that were closer to experimental data than similarly modified ROM-calibrated FEMs. Collectively, these results support the use of BP measures in experimental and model-based investigations of surgical modifications of the spine.
ContributorsSawa, Anna Genowefa Ulrika (Author) / Abbas, James (Thesis advisor) / Crawford, Neil R (Thesis advisor) / Kelly, Brian P (Committee member) / Helms-Tillery, Stephen (Committee member) / Sadleir, Rosalind (Committee member) / Arizona State University (Publisher)
Created2023
157696-Thumbnail Image.png
Description
Previously accomplished research examined sensory integration between upper limb proprioception and tactile sensation. The active proprioceptive-tactile relationship points towards an opportunity to examine neuromodulation effects on sensory integration with respect to proprioceptive error magnitude and direction. Efforts to improve focus and attention during upper limb proprioceptive tasks results in a

Previously accomplished research examined sensory integration between upper limb proprioception and tactile sensation. The active proprioceptive-tactile relationship points towards an opportunity to examine neuromodulation effects on sensory integration with respect to proprioceptive error magnitude and direction. Efforts to improve focus and attention during upper limb proprioceptive tasks results in a decrease of proprioceptive error magnitudes and greater endpoint accuracy. Increased focus and attention can also be correlated to neurophysiological activity in the Locus Coeruleus (LC) during a variety of mental tasks. Through non-invasive trigeminal nerve stimulation, it may be possible to affect the activity of the LC and induce improvements in arousal and attention that would assist in proprioceptive estimation. The trigeminal nerve projects to the LC through the mesencephalic nucleus of the trigeminal complex, providing a pathway similar to the effects seen from vagus nerve stimulation. In this experiment, the effect of trigeminal nerve stimulation (TNS) on proprioceptive ability is evaluated by the proprioceptive estimation error magnitude and direction, while LC activation via autonomic pathways is indirectly measured using pupil diameter, pupil recovery time, and pupil velocity. TNS decreases proprioceptive error magnitude in 59% of subjects, while having no measurable impact on proprioceptive strategy. Autonomic nervous system changes were observed in 88% of subjects, with mostly parasympathetic activation and a mixed sympathetic effect.
ContributorsOrthlieb, Gerrit Chi Luk (Author) / Helms-Tillery, Stephen (Thesis advisor) / Tanner, Justin (Committee member) / Buneo, Christopher (Committee member) / Arizona State University (Publisher)
Created2019