Matching Items (10)
Filtering by

Clear all filters

152336-Thumbnail Image.png
Description
Flow measurement has always been one of the most critical processes in many industrial and clinical applications. The dynamic behavior of flow helps to define the state of a process. An industrial example would be that in an aircraft, where the rate of airflow passing the aircraft is used to

Flow measurement has always been one of the most critical processes in many industrial and clinical applications. The dynamic behavior of flow helps to define the state of a process. An industrial example would be that in an aircraft, where the rate of airflow passing the aircraft is used to determine the speed of the plane. A clinical example would be that the flow of a patient's breath which could help determine the state of the patient's lungs. This project is focused on the flow-meter that are used for airflow measurement in human lungs. In order to do these measurements, resistive-type flow-meters are commonly used in respiratory measurement systems. This method consists of passing the respiratory flow through a fluid resistive component, while measuring the resulting pressure drop, which is linearly related to volumetric flow rate. These types of flow-meters typically have a low frequency response but are adequate for most applications, including spirometry and respiration monitoring. In the case of lung parameter estimation methods, such as the Quick Obstruction Method, it becomes important to have a higher frequency response in the flow-meter so that the high frequency components in the flow are measurable. The following three types of flow-meters were: a. Capillary type b. Screen Pneumotach type c. Square Edge orifice type To measure the frequency response, a sinusoidal flow is generated with a small speaker and passed through the flow-meter that is connected to a large, rigid container. True flow is proportional to the derivative of the pressure inside the container. True flow is then compared with the measured flow, which is proportional to the pressure drop across the flow-meter. In order to do the characterization, two LabVIEW data acquisition programs have been developed, one for transducer calibration, and another one that records flow and pressure data for frequency response testing of the flow-meter. In addition, a model that explains the behavior exhibited by the flow-meter has been proposed and simulated. This model contains a fluid resistor and inductor in series. The final step in this project was to approximate the frequency response data to the developed model expressed as a transfer function.
ContributorsHu, Jianchen (Author) / Macia, Narciso (Thesis advisor) / Pollat, Scott (Committee member) / Rogers, Bradley (Committee member) / Arizona State University (Publisher)
Created2013
150896-Thumbnail Image.png
Description
Human operators have difficulty driving cranes quickly, accurately, and safely because of the slow response of heavy crane structures, non-intuitive control interfaces, and payload oscillations. Recently, a novel hand-motion crane control system has been proposed to improve performance by coupling an intuitive control interface with an element that reduces the

Human operators have difficulty driving cranes quickly, accurately, and safely because of the slow response of heavy crane structures, non-intuitive control interfaces, and payload oscillations. Recently, a novel hand-motion crane control system has been proposed to improve performance by coupling an intuitive control interface with an element that reduces the complex oscillatory behavior of the payload. Hand-motion control allows operators to drive a crane by simply moving a hand-held radio-frequency tag through the desired path. Real-time location sensors are used to track the movements of the tag and the tag position is used in a feedback control loop to drive the crane. An input shaper is added to eliminate dangerous payload oscillations. However, tag position measurements are corrupted by noise. It is important to understand the noise properties so that appropriate filters can be designed to mitigate the effects of noise and improve tracking accuracy. This work discusses implementing filtering techniques to address the issue of noise in the operating environment. Five different filters are used on experimentally-acquired tag trajectories to reduce noise. The filtered trajectories are then used to drive crane simulations. Filter performance is evaluated with respect to the energy usage of the crane trolley, the settling time of the crane payload oscillations, and the safety corridor of the crane trajectory. The effects of filter window lengths on these parameters are also investigated. An adaptive filtering technique, namely the Kalman filter, adapts to the noise characteristics of the workspace to minimize the tag tracking error and performs better than the other filtering techniques examined.
ContributorsRagunathan, Sudarshan (Author) / Frakes, David (Thesis advisor) / Singhose, William (Committee member) / Tillery, Stephen Helms (Committee member) / Arizona State University (Publisher)
Created2012
Description
Optical Fibers coupled to laser light sources, and Light Emitting Diodes are the two classes of technologies used for optogenetic experiments. Arizona State University's Flexible Display Center fabricates novel flexible Organic Light Emitting Diodes(OLEDs). These OLEDs have the capability of being monolithically fabricated over flexible, transparent plastic substrates and having

Optical Fibers coupled to laser light sources, and Light Emitting Diodes are the two classes of technologies used for optogenetic experiments. Arizona State University's Flexible Display Center fabricates novel flexible Organic Light Emitting Diodes(OLEDs). These OLEDs have the capability of being monolithically fabricated over flexible, transparent plastic substrates and having power efficient ways of addressing high density arrays of LEDs. This thesis critically evaluates the technology by identifying the key advantages, current limitations and experimentally assessing the technology in in-vivo and in-vitro animal models. For in-vivo testing, the emitted light from a flat OLED panel was directly used to stimulate the neo-cortex in the M1 region of transgenic mice expressing ChR2 (B6.Cg-Tg (Thy1-ChR2/EYFP) 9Gfng/J). An alternative stimulation paradigm using a collimating optical system coupled with an optical fiber was used for stimulating neurons in layer 5 of the motor cortex in the same transgenic mice. EMG activity was recorded from the contralateral vastus lateralis muscles. In vitro testing of the OLEDs was done in primary cortical neurons in culture transfected with blue light sensitive ChR2. The neurons were cultured on a microelectrode array for taking neuronal recordings.
ContributorsShah, Ankur (Author) / Muthuswamy, Jitendran (Thesis advisor) / Greger, Bradley (Committee member) / Blain Christen, Jennifer (Committee member) / Arizona State University (Publisher)
Created2015
153889-Thumbnail Image.png
Description
Robust and stable decoding of neural signals is imperative for implementing a useful neuroprosthesis capable of carrying out dexterous tasks. A nonhuman primate (NHP) was trained to perform combined flexions of the thumb, index and middle fingers in addition to individual flexions and extensions of the same digits. An array

Robust and stable decoding of neural signals is imperative for implementing a useful neuroprosthesis capable of carrying out dexterous tasks. A nonhuman primate (NHP) was trained to perform combined flexions of the thumb, index and middle fingers in addition to individual flexions and extensions of the same digits. An array of microelectrodes was implanted in the hand area of the motor cortex of the NHP and used to record action potentials during finger movements. A Support Vector Machine (SVM) was used to classify which finger movement the NHP was making based upon action potential firing rates. The effect of four feature selection techniques, Wilcoxon signed-rank test, Relative Importance, Principal Component Analysis, and Mutual Information Maximization was compared based on SVM classification performance. SVM classification was used to examine the functional parameters of (i) efficacy (ii) endurance to simulated failure and (iii) longevity of classification. The effect of using isolated-neuron and multi-unit firing rates was compared as the feature vector supplied to the SVM. The best classification performance was on post-implantation day 36, when using multi-unit firing rates the worst classification accuracy resulted from features selected with Wilcoxon signed-rank test (51.12 ± 0.65%) and the best classification accuracy resulted from Mutual Information Maximization (93.74 ± 0.32%). On this day when using single-unit firing rates, the classification accuracy from the Wilcoxon signed-rank test was 88.85 ± 0.61 % and Mutual Information Maximization was 95.60 ± 0.52% (degrees of freedom =10, level of chance =10%)
ContributorsPadmanaban, Subash (Author) / Greger, Bradley (Thesis advisor) / Santello, Marco (Thesis advisor) / Helms Tillery, Stephen (Committee member) / Arizona State University (Publisher)
Created2015
156937-Thumbnail Image.png
Description
In medical imaging, a wide variety of methods are used to interrogate structural and physiological differences between soft tissues. One of the most ubiquitous methods in clinical practice is Magnetic Resonance Imaging (MRI), which has the advantage of limited invasiveness, soft tissue discrimination, and adequate volumetric resolution. A myriad of

In medical imaging, a wide variety of methods are used to interrogate structural and physiological differences between soft tissues. One of the most ubiquitous methods in clinical practice is Magnetic Resonance Imaging (MRI), which has the advantage of limited invasiveness, soft tissue discrimination, and adequate volumetric resolution. A myriad of advanced MRI methods exists to investigate the microstructural, physiologic and metabolic characteristics of tissue. For example, Dynamic Contrast Enhanced (DCE) and Dynamic Susceptibility Contrast (DSC) MRI non-invasively interrogates the dynamic passage of an exogenously administered MRI contrast agent through tissue to quantify local tracer kinetic properties like blood flow, vascular permeability and tissue compartmental volume fractions. Recently, an improved understanding of the biophysical basis of DSC-MRI signals in brain tumors revealed a new approach to derive multiple quantitative biomarkers that identify intrinsic sub-voxel cellular and vascular microstructure that can be used differentiate tumor sub-types. One of these characteristic biomarkers called Transverse Relaxivity at Tracer Equilibrium (TRATE), utilizes a combination of DCE and DSC techniques to compute a steady-state metric which is particularly sensitive to cell size, density, and packing properties. This work seeks to investigate the sensitivity and potential utility of TRATE in a range of disease states including Glioblastomas, Amyotrophic Lateral Sclerosis (ALS), and Duchenne’s Muscular Dystrophy (DMD). The MRC measures of TRATE showed the most promise in mouse models of ALS where TRATE values decreased with disease progression, a finding that correlated with reductions in myofiber size and area, as quantified by immunohistochemistry. In the animal models of cancer and DMD, TRATE results were more inconclusive, due to marked heterogeneity across animals and treatment state. Overall, TRATE seems to be a promising new biomarker but still needs further methodological refinement due to its sensitivity to contrast to noise and further characterization owing to its non-specificity with respect to multiple cellular features (e.g. size, density, heterogeneity) that complicate interpretation.
ContributorsFuentes, Alberto (Author) / Quarles, Chad C (Thesis advisor) / Kodibagkar, Vikram (Thesis advisor) / Greger, Bradley (Committee member) / Arizona State University (Publisher)
Created2018
153632-Thumbnail Image.png
Description
Intracranial pressure is an important parameter to monitor, and elevated intracranial pressure can be life threatening. Elevated intracranial pressure is indicative of distress in the brain attributed by conditions such as aneurysm, traumatic brain injury, brain tumor, hydrocephalus, stroke, or meningitis.

Electrocorticography (ECoG) recordings are invaluable in understanding epilepsy and

Intracranial pressure is an important parameter to monitor, and elevated intracranial pressure can be life threatening. Elevated intracranial pressure is indicative of distress in the brain attributed by conditions such as aneurysm, traumatic brain injury, brain tumor, hydrocephalus, stroke, or meningitis.

Electrocorticography (ECoG) recordings are invaluable in understanding epilepsy and detecting seizure zones. However, ECoG electrodes cause a foreign body mass effect, swelling, and pneumocephaly, which results in elevation of intracranial pressure (ICP). Thus, the aim of this work is to design an intracranial pressure monitoring system that could augment ECoG electrodes.

A minimally invasive, low-cost epidural intracranial pressure monitoring system is developed for this purpose, using a commercial pressure transducer available for biomedical applications. The system is composed of a pressure transducer, sensing cup, electronics, and data acquisition system. The pressure transducer is a microelectromechanical system (MEMS)-based die that works on piezoresistive phenomenon with dielectric isolation for direct contact with fluids.

The developed system was bench tested and verified in an animal model to confirm the efficacy of the system for intracranial pressure monitoring. The system has a 0.1 mmHg accuracy and a 2% error for the 0-10 mmHg range, with resolution of 0.01 mmHg. This system serves as a minimally invasive (2 mm burr hole) epidural ICP monitor, which could augment existing ECoG electrode arrays, to simultaneously measure intracranial pressure along with the neural signals.

This device could also be employed with brain implants that causes elevation in ICP due to tissue - implant interaction often leading to edema. This research explores the concept and feasibility for integrating the sensing component directly on to the ECoG electrode arrays.
ContributorsSampath Kumaran, Ranjani (Author) / Christen, Jennifer Blain (Thesis advisor) / Tillery, Stephen Helms (Committee member) / Greger, Bradley (Committee member) / Arizona State University (Publisher)
Created2015
Description
Understanding human-human interactions during the performance of joint motor tasks is critical for developing rehabilitation robots that could aid therapists in providing effective treatments for motor problems. However, there is a lack of understanding of strategies (cooperative or competitive) adopted by humans when interacting with other individuals. Previous studies have

Understanding human-human interactions during the performance of joint motor tasks is critical for developing rehabilitation robots that could aid therapists in providing effective treatments for motor problems. However, there is a lack of understanding of strategies (cooperative or competitive) adopted by humans when interacting with other individuals. Previous studies have investigated the cues (auditory, visual and haptic) that support these interactions but understanding how these unconscious interactions happen even without those cues is yet to be explained. To address this issue, in this study, a paradigm that tests the parallel efforts of pairs of individuals (dyads) to complete a jointly performed virtual reaching task, without any auditory or visual information exchange was employed. Motion was tracked with a NDI OptoTrak 3D motion tracking system that captured each subject’s movement kinematics, through which we could measure the level of synchronization between two subjects in space and time. For the spatial analyses, the movement amplitudes and direction errors at peak velocities and at endpoints were analyzed. Significant differences in the movement amplitudes were found for subjects in 4 out of 6 dyads which were expected due to the lack of feedback between the subjects. Interestingly, subjects in this study also planned their movements in different directions in order to counteract the visuomotor rotation offered in the test blocks, which suggests the difference in strategies for the subjects in each dyad. Also, the level of de-adaptation in the control blocks in which no visuomotor rotation was offered to the subjects was measured. To further validate the results obtained through spatial analyses, a temporal analyses was done in which the movement times for the two subjects were compared. With the help of these results, numerous interaction scenarios that are possible in the human joint actions in without feedback were analyzed.
ContributorsAgrawal, Ankit (Author) / Buneo, Christopher (Thesis advisor) / Santello, Marco (Committee member) / Tillery, Stephen Helms (Committee member) / Arizona State University (Publisher)
Created2016
153709-Thumbnail Image.png
Description
Bioimpedance measurements have been long used for monitoring tissue ischemia and blood flow. This research employs implantable microelectronic devices to measure impedance chronically as a potential way to monitor the progress of peripheral vascular disease (PVD). Ultrasonically powered implantable microdevices previously developed for the purposes of neuroelectric vasodilation for therapeutic

Bioimpedance measurements have been long used for monitoring tissue ischemia and blood flow. This research employs implantable microelectronic devices to measure impedance chronically as a potential way to monitor the progress of peripheral vascular disease (PVD). Ultrasonically powered implantable microdevices previously developed for the purposes of neuroelectric vasodilation for therapeutic treatment of PVD were found to also allow a secondary function of tissue bioimpedance monitoring. Having no structural differences between devices used for neurostimulation and impedance measurements, there is a potential for double functionality and closed loop control of the neurostimulation performed by these types of microimplants. The proposed technique involves actuation of the implantable microdevices using a frequency-swept amplitude modulated continuous waveform ultrasound and remote monitoring of induced tissue current. The design has been investigated using simulations, ex vivo testing, and preliminary animal experiments. Obtained results have demonstrated the ability of ultrasonically powered neurostimulators to be sensitive to the impedance changes of tissue surrounding the device and wirelessly report impedance spectra. Present work suggests the potential feasibility of wireless tissue impedance measurements for PVD applications as a complement to neurostimulation.
ContributorsCelinskis, Dmitrijs (Author) / Towe, Bruce (Thesis advisor) / Greger, Bradley (Committee member) / Sadleir, Rosalind (Committee member) / Arizona State University (Publisher)
Created2015
158637-Thumbnail Image.png
Description
The ability to inhibit a planned but inappropriate response, and switch to executing a goal-relevant motor response, is critically important for the regulation of motor behaviors. Inhibition and switching could be mediated by various control mechanisms. Proactive control uses contextual information (cues) to plan the response for the target stimulus

The ability to inhibit a planned but inappropriate response, and switch to executing a goal-relevant motor response, is critically important for the regulation of motor behaviors. Inhibition and switching could be mediated by various control mechanisms. Proactive control uses contextual information (cues) to plan the response for the target stimulus (probe) based on the expectation of a response inhibition or switching stimulus combination. Previous work has reported the involvement of several brain areas associated with proactive inhibition and switching, e.g., dorsolateral prefrontal cortex, anterior cingulate cortex, inferior frontal junction, and pre-supplementary motor area. However, how these areas interact and their functional role in different types of cognitive control is still debated. An AX-version of the continuous performance task (AX-CPT) was used to examine proactive inhibition and switching of motor actions. In a typical AX-CPT trial, a contextual cue stimulus is presented, followed by a probe stimulus after a specific inter-stimulus interval. As part of a trial sequence, if a target cue and target probe are presented, a target response is to be provided when the probe is observed. Otherwise, a non-target response is to be provided for all other stimuli. A behavioral switching AX-CPT experiment (48 subjects) was conducted to explore the parameters that induce a proactive shift in the motor response. Participants who performed the AX-CPT task with relatively shorter interstimulus interval predominantly and consistently exhibited proactive control behavior. A follow-up pilot study (3 subjects) of response inhibition versus response switching AX-CPT was performed using 256-channel high-density electroencephalography (HD-EEG). HD-EEG was used to identify the time course of cortical activation in brain areas associated with response inhibition. It was observed that one out of three participants used a proactive strategy for response switching based on probe response error and probe response reaction time. Instantaneous amplitude spatial maps obtained from HD-EEG revealed cortical activity corresponding to conflict between proactively-prepared incorrect responses and reactively-corrected goal-relevant responses after the probe was presented.
ContributorsMysore, Archana Shashidhar (Author) / Santello, Marco (Thesis advisor) / Blais, Christopher (Committee member) / Brewer, Gene (Committee member) / Tillery, Stephen Helms (Committee member) / Arizona State University (Publisher)
Created2020
158383-Thumbnail Image.png
Description
Brain micromotion is a phenomenon that arises from basic physiological functions such as respiration (breathing) and vascular pulsation (pumping blood or heart rate). These physiological processes cause small micro displacements of 2-4µm for vascular pulsation and 10-30µm for respiration, in rat models. One problem related to micromotion is the instability

Brain micromotion is a phenomenon that arises from basic physiological functions such as respiration (breathing) and vascular pulsation (pumping blood or heart rate). These physiological processes cause small micro displacements of 2-4µm for vascular pulsation and 10-30µm for respiration, in rat models. One problem related to micromotion is the instability of the probe and its ability to acquire stable neural recordings in chronic studies. It has long been thought the membrane potential (MP) changes due to micromotion in the presence of brain implants were an artefact caused by the implant. Here is shown that intracellular membrane potential changes are a consequence of the activation of mechanosensitive ion channels at the neural interface. A combination of aplysia and rat animal models were used to show activation of mechanosensitive ion channels is occurring during a neural recording. During simulated micromotion of displacements of 50μm and 100μm at a frequency of 1 Hz, showed a change of 8 and 10mV respectively and that the addition of Ethylenediaminetetraacetic acid (EDTA) inhibited the membrane potential changes. The application of EDTA showed a 71% decrease in changes in membrane potential changes due to micromotion. Simulation of breathing using periodic motion of a probe in an Aplysia model showed that there were no membrane potential changes for <1.5kPa and action potentials were observed at >3.1kPa. Drug studies utilizing 5-HT showed an 80% reduction in membrane potentials. To validate the electrophysiological changes due to micromotion in a rat model, a double barrel pipette for simultaneous recording and drug delivery was designed, the drug delivery tip was recessed from the recording tip no greater than 50μm on average. The double barrel pipette using iontophoresis was used to deliver 30 μM of Gadolinium Chloride (Gd3+) into the microenvironment of the cell. Here is shown a significant reduction in membrane potential for n = 13 cells across 4 different rats tested using Gd3+. Membrane potential changes related to breathing and vascular pulsation were reduced between approximately 0.25-2.5 mV for both breathing and heart rate after the addition of Gd3+, a known mechanosensitive ion channel blocker.
ContributorsDuncan, Jonathan Leroy (Author) / Muthuswamy, Jitendran (Thesis advisor) / Greger, Bradley (Committee member) / Sridharan, Arati (Committee member) / Arizona State University (Publisher)
Created2020