Flow measurement has always been one of the most critical processes in many industrial and clinical applications. The dynamic behavior of flow helps to define the state of a process. An industrial example would be that in an aircraft, where the rate of airflow passing the aircraft is used to

Flow measurement has always been one of the most critical processes in many industrial and clinical applications. The dynamic behavior of flow helps to define the state of a process. An industrial example would be that in an aircraft, where the rate of airflow passing the aircraft is used to determine the speed of the plane. A clinical example would be that the flow of a patient's breath which could help determine the state of the patient's lungs. This project is focused on the flow-meter that are used for airflow measurement in human lungs. In order to do these measurements, resistive-type flow-meters are commonly used in respiratory measurement systems. This method consists of passing the respiratory flow through a fluid resistive component, while measuring the resulting pressure drop, which is linearly related to volumetric flow rate. These types of flow-meters typically have a low frequency response but are adequate for most applications, including spirometry and respiration monitoring. In the case of lung parameter estimation methods, such as the Quick Obstruction Method, it becomes important to have a higher frequency response in the flow-meter so that the high frequency components in the flow are measurable. The following three types of flow-meters were: a. Capillary type b. Screen Pneumotach type c. Square Edge orifice type To measure the frequency response, a sinusoidal flow is generated with a small speaker and passed through the flow-meter that is connected to a large, rigid container. True flow is proportional to the derivative of the pressure inside the container. True flow is then compared with the measured flow, which is proportional to the pressure drop across the flow-meter. In order to do the characterization, two LabVIEW data acquisition programs have been developed, one for transducer calibration, and another one that records flow and pressure data for frequency response testing of the flow-meter. In addition, a model that explains the behavior exhibited by the flow-meter has been proposed and simulated. This model contains a fluid resistor and inductor in series. The final step in this project was to approximate the frequency response data to the developed model expressed as a transfer function.
ContributorsHu, Jianchen (Author) / Macia, Narciso (Thesis advisor) / Pollat, Scott (Committee member) / Rogers, Bradley (Committee member) / Arizona State University (Publisher)
Created2013
150217-Thumbnail Image.png
Description
The past two decades have been monumental in the advancement of microchips designed for a diverse range of medical applications and bio-analysis. Owing to the remarkable progress in micro-fabrication technology, complex chemical and electro-mechanical features can now be integrated into chip-scale devices for use in biosensing and physiological measurements. Some

The past two decades have been monumental in the advancement of microchips designed for a diverse range of medical applications and bio-analysis. Owing to the remarkable progress in micro-fabrication technology, complex chemical and electro-mechanical features can now be integrated into chip-scale devices for use in biosensing and physiological measurements. Some of these devices have made enormous contributions in the study of complex biochemical processes occurring at the molecular and cellular levels while others overcame the challenges of replicating various functions of human organs as implant systems. This thesis presents test data and analysis of two such systems. First, an ISFET based pH sensor is characterized for its performance in a continuous pH monitoring application. Many of the basic properties of ISFETs including I-V characteristics, pH sensitivity and more importantly, its long term drift behavior have been investigated. A new theory based on frequent switching of electric field across the gate oxide to decrease the rate of current drift has been successfully implemented with the help of an automated data acquisition and switching system. The system was further tested for a range of duty cycles in order to accurately determine the minimum length of time required to fully reset the drift. Second, a microfluidic based vestibular implant system was tested for its underlying characteristics as a light sensor. A computer controlled tilt platform was then implemented to further test its sensitivity to inclinations and thus it‟s more important role as a tilt sensor. The sensor operates through means of optoelectronics and relies on the signals generated from photodiode arrays as a result of light being incident on them. ISFET results show a significant drop in the overall drift and good linear characteristics. The drift was seen to reset at less than an hour. The photodiodes show ideal I-V comparison between photoconductive and photovoltaic modes of operation with maximum responsivity at 400nm and a shunt resistance of 394 MΩ. Additionally, post-processing of the tilt sensor to incorporate the sensing fluids is outlined. Based on several test and fabrication results, a possible method of sealing the open cavity of the chip using a UV curable epoxy has been discussed.
ContributorsMamun, Samiha (Author) / Christen, Jennifer Blain (Thesis advisor) / Goryll, Michael (Committee member) / Yu, Hongyu (Committee member) / Arizona State University (Publisher)
Created2011
150927-Thumbnail Image.png
Description
Due to heterogeneity at the cellular level, single cell analysis (SCA) has become a necessity to study cellomics for the early detection of diseases like cancer. Development of single cell manipulation systems is very critical for performing SCA. In this thesis, electrorotation (ROT) chips to trap and rotate single cells

Due to heterogeneity at the cellular level, single cell analysis (SCA) has become a necessity to study cellomics for the early detection of diseases like cancer. Development of single cell manipulation systems is very critical for performing SCA. In this thesis, electrorotation (ROT) chips to trap and rotate single cells using electrokinetic forces have been developed. The ROT chip mainly consists of a set of closely spaced metal electrodes (60µm interspacing between opposite electrodes) that forms a closed electric field cage (electrocage) when driven with high frequency AC voltages. Cells were flowed through a microchannel to the electrocage where they could be precisely trapped, levitated and rotated in 3-D along the axis of interest. The dielectrophoresis based ROT chip design and relevant electrokinetic effects have been simulated using COMSOL 3.4 to optimize the design parameters. Also, various semiconductor technology fabrication process steps have been developed and optimized for better yield and repeatability in the manufacture of the ROT chip. The ROT chip thus fabricated was used to characterize rotation of single cells with respect to the control parameters namely excitation voltage, frequency and cell line. The longevity of cell rotation under electric fields has been probed. Also, the Joule heating inside the ROT chip due to applied voltage has been characterized to know the thermal stress on the cells. The major advantages of the ROT chip developed are precise electrorotation of cells, simple design and straight forward fabrication process.
ContributorsSoundappa Elango, Iniyan (Author) / Meldrum, Deirdre R (Thesis advisor) / Christen, Jennifer Blain (Committee member) / Johnson, Roger H (Committee member) / Arizona State University (Publisher)
Created2012
153632-Thumbnail Image.png
Description
Intracranial pressure is an important parameter to monitor, and elevated intracranial pressure can be life threatening. Elevated intracranial pressure is indicative of distress in the brain attributed by conditions such as aneurysm, traumatic brain injury, brain tumor, hydrocephalus, stroke, or meningitis.

Electrocorticography (ECoG) recordings are invaluable in understanding epilepsy and

Intracranial pressure is an important parameter to monitor, and elevated intracranial pressure can be life threatening. Elevated intracranial pressure is indicative of distress in the brain attributed by conditions such as aneurysm, traumatic brain injury, brain tumor, hydrocephalus, stroke, or meningitis.

Electrocorticography (ECoG) recordings are invaluable in understanding epilepsy and detecting seizure zones. However, ECoG electrodes cause a foreign body mass effect, swelling, and pneumocephaly, which results in elevation of intracranial pressure (ICP). Thus, the aim of this work is to design an intracranial pressure monitoring system that could augment ECoG electrodes.

A minimally invasive, low-cost epidural intracranial pressure monitoring system is developed for this purpose, using a commercial pressure transducer available for biomedical applications. The system is composed of a pressure transducer, sensing cup, electronics, and data acquisition system. The pressure transducer is a microelectromechanical system (MEMS)-based die that works on piezoresistive phenomenon with dielectric isolation for direct contact with fluids.

The developed system was bench tested and verified in an animal model to confirm the efficacy of the system for intracranial pressure monitoring. The system has a 0.1 mmHg accuracy and a 2% error for the 0-10 mmHg range, with resolution of 0.01 mmHg. This system serves as a minimally invasive (2 mm burr hole) epidural ICP monitor, which could augment existing ECoG electrode arrays, to simultaneously measure intracranial pressure along with the neural signals.

This device could also be employed with brain implants that causes elevation in ICP due to tissue - implant interaction often leading to edema. This research explores the concept and feasibility for integrating the sensing component directly on to the ECoG electrode arrays.
ContributorsSampath Kumaran, Ranjani (Author) / Christen, Jennifer Blain (Thesis advisor) / Tillery, Stephen Helms (Committee member) / Greger, Bradley (Committee member) / Arizona State University (Publisher)
Created2015
157755-Thumbnail Image.png
Description
Developing countries suffer from various health challenges due to inaccessible medical diagnostic laboratories and lack of resources to establish new laboratories. One way to address these issues is to develop diagnostic systems that are suitable for the low-resource setting. In addition to this, applications requiring rapid analyses further motivates the

Developing countries suffer from various health challenges due to inaccessible medical diagnostic laboratories and lack of resources to establish new laboratories. One way to address these issues is to develop diagnostic systems that are suitable for the low-resource setting. In addition to this, applications requiring rapid analyses further motivates the development of portable, easy-to-use, and accurate Point of Care (POC) diagnostics. Lateral Flow Immunoassays (LFIAs) are among the most successful POC tests as they satisfy most of the ASSURED criteria. However, factors like reagent stability, reaction rates limit the performance and robustness of LFIAs. The fluid flow rate in LFIA significantly affect the factors mentioned above, and hence, it is desirable to maintain an optimal fluid velocity in porous media.

The main objective of this study is to build a statistical model that enables us to determine the optimal design parameters and ambient conditions for achieving a desired fluid velocity in porous media. This study mainly focuses on the effects of relative humidity and temperature on evaporation in porous media and the impact of geometry on fluid velocity in LFIAs. A set of finite element analyses were performed, and the obtained simulation results were then experimentally verified using Whatman filter paper with different geometry under varying ambient conditions. Design of experiments was conducted to estimate the significant factors affecting the fluid flow rate.

Literature suggests that liquid evaporation is one of the major factors that inhibit fluid penetration and capillary flow in lateral flow Immunoassays. The obtained results closely align with the existing literature and conclude that a desired fluid flow rate can be achieved by tuning the geometry of the porous media. The derived statistical model suggests that a dry and warm atmosphere is expected to inhibit the fluid flow rate the most and vice-versa.
ContributorsThamatam, Nipun (Author) / Christen, Jennifer Blain (Thesis advisor) / Goryll, Michael (Committee member) / Thornton, Trevor (Committee member) / Arizona State University (Publisher)
Created2019