Matching Items (5)
Filtering by

Clear all filters

151067-Thumbnail Image.png
Description
Aqueous solutions of temperature-responsive copolymers based on N-isopropylacrylamide (NIPAAm) hold promise for medical applications because they can be delivered as liquids and quickly form gels in the body without organic solvents or chemical reaction. However, their gelation is often followed by phase-separation and shrinking. Gel shrinking and water loss is

Aqueous solutions of temperature-responsive copolymers based on N-isopropylacrylamide (NIPAAm) hold promise for medical applications because they can be delivered as liquids and quickly form gels in the body without organic solvents or chemical reaction. However, their gelation is often followed by phase-separation and shrinking. Gel shrinking and water loss is a major limitation to using NIPAAm-based gels for nearly any biomedical application. In this work, a graft copolymer design was used to synthesize polymers which combine the convenient injectability of poly(NIPAAm) with gel water content controlled by hydrophilic side-chain grafts based on Jeffamine® M-1000 acrylamide (JAAm). The first segment of this work describes the synthesis and characterization of poly(NIPAAm-co-JAAm) copolymers which demonstrates controlled swelling that is nearly independent of LCST. The graft copolymer design was then used to produce a degradable antimicrobial-eluting gel for prevention of prosthetic joint infection. The resorbable graft copolymer gels were shown to have three unique characteristics which demonstrate their suitability for this application. First, antimicrobial release is sustained and complete within 1 week. Second, the gels behave like viscoelastic fluids, enabling complete surface coverage of an implant without disrupting fixation or movement. Finally, the gels degrade rapidly within 1-6 weeks, which may enable their use in interfaces where bone healing takes place. Graft copolymer hydrogels were also developed which undergo Michael addition in situ with poly(ethylene glycol) diacrylate to form elastic gels for endovascular embolization of saccular aneurysms. Inclusion of JAAm grafts led to weaker physical crosslinking and faster, more complete chemical crosslinking. JAAm grafts prolonged the delivery window of the system from 30 seconds to 220 seconds, provided improved gel swelling, and resulted in stronger, more elastic gels within 30 minutes after delivery.
ContributorsOverstreet, Derek (Author) / Caplan, Michael (Thesis advisor) / Massia, Stephen (Committee member) / Mclaren, Alexander (Committee member) / Vernon, Brent (Committee member) / McLemore, Ryan (Committee member) / Arizona State University (Publisher)
Created2012
137550-Thumbnail Image.png
Description
This report provides information concerning qualities of methylcellulose and how those properties affect further experimentation within the biomedical world. Utilizing the compound’s biocompatibility many issues, ranging from surgical to cosmetic, can be solved. As of recent, studies indicate, methylcellulose has been used as a physically cross-linked gel, which

This report provides information concerning qualities of methylcellulose and how those properties affect further experimentation within the biomedical world. Utilizing the compound’s biocompatibility many issues, ranging from surgical to cosmetic, can be solved. As of recent, studies indicate, methylcellulose has been used as a physically cross-linked gel, which cannot sustain a solid form within the body. Therefore, this report will ultimately explore the means of creating a non-degradable, injectable, chemically cross-linking methylcellulose- based hydrogel. Methylcellulose will be evaluated and altered in experiments conducted within this report and a chemical cross-linker, developed from Jeffamine ED 2003 (O,O′-Bis(2-aminopropyl) polypropylene glycol-block-polyethylene glycol-block-polypropylene glycol), will be created. Experimentation with these elements is outlined here, and will ultimately prompt future revisions and analysis.
ContributorsBundalo, Zoran Luka (Author) / Vernon, Brent (Thesis director) / LaBelle, Jeffrey (Committee member) / Overstreet, Derek (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor)
Created2013-05
137564-Thumbnail Image.png
Description
Revision hip procedures represent a large financial burden on hospitals and the problem will continue to worsen as the baby boomer generation ages and life expectancy goes up. The future problem is a complex issue that bridges scientific and anecdotal evidence and must be solved. A review of the current

Revision hip procedures represent a large financial burden on hospitals and the problem will continue to worsen as the baby boomer generation ages and life expectancy goes up. The future problem is a complex issue that bridges scientific and anecdotal evidence and must be solved. A review of the current total hip arthroplasty procedure in regards to the physical properties of the materials used for hip prostheses is given. Revision procedures can be caused by infection or basic wear and tear from the stress that that implant is subjected to daily. Infections on these implants often present themselves as medical biofilms. The mechanisms of biofilm formation include a complex system of enzymes that work to initiate a phenotypic response based on an established quorum sensing within the colony of bacteria. Surgical methods to treat infection include irrigation and debridement as well as loading drug cement spacers with antimicrobial in hopes of delivering the antibiotic locally. Research is being done to better model the transport of drug through the tissue surrounding the implant, and will hopefully one day be available for use in individual patients.
ContributorsMcDermand, Matthew Paul (Author) / Caplan, Michael (Thesis director) / Vernon, Brent (Committee member) / McLemore, Ryan (Committee member) / Barrett, The Honors College (Contributor)
Created2013-05
137683-Thumbnail Image.png
Description
Rupture of intracranial aneurysms causes a subarachnoid hemorrhage, which is often lethal health event. A minimally invasive method of solving this problem may involve a material, which can be administered as a liquid and then becomes a strong solid within minutes preventing flow of blood in the aneurysm. Here we

Rupture of intracranial aneurysms causes a subarachnoid hemorrhage, which is often lethal health event. A minimally invasive method of solving this problem may involve a material, which can be administered as a liquid and then becomes a strong solid within minutes preventing flow of blood in the aneurysm. Here we report on the development of temperature responsive copolymers, which are deliverable through a microcatheter at body temperature and then rapidly cure to form a highly elastic hydrogel. To our knowledge, this is the first physical-and chemical-crosslinked hydrogel capable of rapid crosslinking at temperatures above the gel transition temperature. The polymer system, poly(N-isopropylacrylamide-co-cysteamine-co-Jeffamine® M-1000 acrylamide) and poly(ethylene glycol) diacrylate, was evaluated in wide-neck aneurysm flow models to evaluate the stability of the hydrogels. Investigation of this polymer system indicates that the Jeffamine® M-1000 causes the gels to retain water, resulting in gels that are initially weak and viscous, but become stronger and more elastic after chemical crosslinking.
ContributorsLee, Elizabeth Jean (Author) / Vernon, Brent (Thesis director) / Brennecka, Celeste (Committee member) / Overstreet, Derek (Committee member) / Barrett, The Honors College (Contributor) / School of Mathematical and Statistical Sciences (Contributor)
Created2013-05
161830-Thumbnail Image.png
Description
Technology transfer hurdles constantly keep effective medical treatment from healthcare. One prevalent hurdle is that of cost. Regulation from any organization or entity can drive up cost and requires thorough review before implementation. For microspheres specifically, extensive research has been conducted to minimize variation in size. How variation effects drug

Technology transfer hurdles constantly keep effective medical treatment from healthcare. One prevalent hurdle is that of cost. Regulation from any organization or entity can drive up cost and requires thorough review before implementation. For microspheres specifically, extensive research has been conducted to minimize variation in size. How variation effects drug delivery of microspheres, however, has not been studied in depth. In this study, a preliminary approach to modeling drug delivery in microspheres with a given log-normal distribution is reported. A design of experiment statistical analysis was performed using incremental values of mean and standard deviation. To estimate the rate of drug diffusing from the microspheres, a simplified Fick's second law was used. Various data types were considered and it was found that the shape factors which are related to mean and standard deviation fit the statistical analysis best. Using the shape factor data type, equation characteristics were identified and reported. It was seen that standard deviation has a greater influence on drug delivery than mean. A prediction expression is presented that can be used to identify the time it takes to get to 60% drug delivery and can be used in a scaled manner.
ContributorsNickle, Jacob Aaron (Author) / Vernon, Brent (Thesis advisor) / McLemore, Ryan (Committee member) / Beeman, Scott (Committee member) / Arizona State University (Publisher)
Created2021