Matching Items (1)
Filtering by

Clear all filters

190929-Thumbnail Image.png
Description
Magnetic resonance imaging (MRI) is the most powerful instrument for imaging anatomical structures. One of the most essential components of the MRI scanner is a radiofrequency (RF) coil. It induces resonant phenomena and receives the resonated RF signal from the body. Then, the signal is computed and reconstructed for MR

Magnetic resonance imaging (MRI) is the most powerful instrument for imaging anatomical structures. One of the most essential components of the MRI scanner is a radiofrequency (RF) coil. It induces resonant phenomena and receives the resonated RF signal from the body. Then, the signal is computed and reconstructed for MR images. Therefore, improving image quality by increasing the receiver's (Rx) efficiency is always remarkable. This research introduces a flexible and stretchable receive RF coil embedded in a dielectric-loaded material. Recent studies show that the adaptable coil can improve imaging quality by flexing and stretching to fit well with the sample's surface, reducing the spatial distance between the load and the coil. High permittivity dielectric material positioned between the coil and phantom was known to increase the RF field distribution's efficiency significantly. Recent studies integrating the high dielectric material with the coil show a significant improvement in signal-to-noise ratio (SNR), which can improve the overall efficiency of the coil. Previous research also introduced new elastic dielectric material, which shows improvement in uniformity when incorporated with an RF coil. Combining the adaptable RF coil with the elastic dielectric material has the potential to enhance the coil's performance further. The flexible dielectric material's limitations and unknown interaction with the coil pose a challenge. Thus, each component was integrated into a simple loop coil step-by-step, which allowed for experimentation and evaluation of the performance of each part. The mechanical performance was tested manually. The introduced coil is highly flexible and can stretch up to 20% of its original length in one direction. The electrical performance was evaluated in simulations and experiments on a 9.4T MRI scanner compared to conventional RF coils.
ContributorsHerabut, Chavalchart (Author) / Sohn, SungMin (Thesis advisor) / Sadleir, Rosalind (Committee member) / Beeman, Scott (Committee member) / Arizona State University (Publisher)
Created2023