Matching Items (36)
Filtering by

Clear all filters

Description
Single cell phenotypic heterogeneity studies reveal more information about the pathogenesis process than conventional bulk methods. Furthermore, investigation of the individual cellular response mechanism during rapid environmental changes can only be achieved at single cell level. By enabling the study of cellular morphology, a single cell three-dimensional (3D) imaging system

Single cell phenotypic heterogeneity studies reveal more information about the pathogenesis process than conventional bulk methods. Furthermore, investigation of the individual cellular response mechanism during rapid environmental changes can only be achieved at single cell level. By enabling the study of cellular morphology, a single cell three-dimensional (3D) imaging system can be used to diagnose fatal diseases, such as cancer, at an early stage. One proven method, CellCT, accomplishes 3D imaging by rotating a single cell around a fixed axis. However, some existing cell rotating mechanisms require either intricate microfabrication, and some fail to provide a suitable environment for living cells. This thesis develops a microvorterx chamber that allows living cells to be rotated by hydrodynamic alone while facilitating imaging access. In this thesis work, 1) the new chamber design was developed through numerical simulation. Simulations revealed that in order to form a microvortex in the side chamber, the ratio of the chamber opening to the channel width must be smaller than one. After comparing different chamber designs, the trapezoidal side chamber was selected because it demonstrated controllable circulation and met the imaging requirements. Microvortex properties were not sensitive to the chambers with interface angles ranging from 0.32 to 0.64. A similar trend was observed when chamber heights were larger than chamber opening. 2) Micro-particle image velocimetry was used to characterize microvortices and validate simulation results. Agreement between experimentation and simulation confirmed that numerical simulation was an effective method for chamber design. 3) Finally, cell rotation experiments were performed in the trapezoidal side chamber. The experimental results demonstrated cell rotational rates ranging from 12 to 29 rpm for regular cells. With a volumetric flow rate of 0.5 µL/s, an irregular cell rotated at a mean rate of 97 ± 3 rpm. Rotational rates can be changed by altering inlet flow rates.
ContributorsZhang, Wenjie (Author) / Frakes, David (Thesis advisor) / Meldrum, Deirdre (Thesis advisor) / Chao, Shih-hui (Committee member) / Wang, Xiao (Committee member) / Arizona State University (Publisher)
Created2011
151433-Thumbnail Image.png
Description
Sensitivity is a fundamental challenge for in vivo molecular magnetic resonance imaging (MRI). Here, I improve the sensitivity of metal nanoparticle contrast agents by strategically incorporating pure and doped metal oxides in the nanoparticle core, forming a soluble, monodisperse, contrast agent with adjustable T2 or T1 relaxivity (r2 or r1).

Sensitivity is a fundamental challenge for in vivo molecular magnetic resonance imaging (MRI). Here, I improve the sensitivity of metal nanoparticle contrast agents by strategically incorporating pure and doped metal oxides in the nanoparticle core, forming a soluble, monodisperse, contrast agent with adjustable T2 or T1 relaxivity (r2 or r1). I first developed a simplified technique to incorporate iron oxides in apoferritin to form "magnetoferritin" for nM-level detection with T2- and T2* weighting. I then explored whether the crystal could be chemically modified to form a particle with high r1. I first adsorbed Mn2+ ions to metal binding sites in the apoferritin pores. The strategic placement of metal ions near sites of water exchange and within the crystal oxide enhance r1, suggesting a mechanism for increasing relaxivity in porous nanoparticle agents. However, the Mn2+ addition was only possible when the particle was simultaneously filled with an iron oxide, resulting in a particle with a high r1 but also a high r2 and making them undetectable with conventional T1-weighting techniques. To solve this problem and decrease the particle r2 for more sensitive detection, I chemically doped the nanoparticles with tungsten to form a disordered W-Fe oxide composite in the apoferritin core. This configuration formed a particle with a r1 of 4,870mM-1s-1 and r2 of 9,076mM-1s-1. These relaxivities allowed the detection of concentrations ranging from 20nM - 400nM in vivo, both passively injected and targeted to the kidney glomerulus. I further developed an MRI acquisition technique to distinguish particles based on r2/r1, and show that three nanoparticles of similar size can be distinguished in vitro and in vivo with MRI. This work forms the basis for a new, highly flexible inorganic approach to design nanoparticle contrast agents for molecular MRI.
ContributorsClavijo Jordan, Maria Veronica (Author) / Bennett, Kevin M (Thesis advisor) / Kodibagkar, Vikram (Committee member) / Sherry, A Dean (Committee member) / Wang, Xiao (Committee member) / Yarger, Jeffery (Committee member) / Arizona State University (Publisher)
Created2012
151372-Thumbnail Image.png
Description
The object of this study is to charac terize the effect of focused ultrasound stimulation (FUS) on the rat ce rvix which has been observed to speed its ripening during pregnancy. Ce rvical ripening is required for successful fetal delivery. Timed-pregnant Sprague-Dawley rats (n=36) were used. On day 14 of

The object of this study is to charac terize the effect of focused ultrasound stimulation (FUS) on the rat ce rvix which has been observed to speed its ripening during pregnancy. Ce rvical ripening is required for successful fetal delivery. Timed-pregnant Sprague-Dawley rats (n=36) were used. On day 14 of gestation, the FUS system was placed on the body surface of the rat over the cervix and ultrasound energy was applied to cervix for variable times up to 1 hour in the control group, the FUS system was placed on rats but no energy was applied. Daily measurement of cervix light-induced florescence (LIF, photon counts of collagen x-bridge fluorescence) were made on days 16 of gestation and daily until spont-aneous delivery (day22) to estimate changes in cervical ripening. We found that pulses of 680 KHz ultrasound at 25 Hertz, 1 millisecond pulse duration at 1W/cm^2 applied for as little as 30 minutes would immediately afterwards show the cervix to hav e ripened to the degree seen just before delivery on day 22. Delivery times, fetal weights and viability were unaffected in the FUS-treated animals.
ContributorsLuo, Daishen (Author) / Towe, Bruce C (Thesis advisor) / Wang, Xiao (Committee member) / Caplan, Michael (Committee member) / Arizona State University (Publisher)
Created2012
135480-Thumbnail Image.png
Description
Compressed sensing magnetic resonance spectroscopic imaging (MRSI) is a noninvasive and in vivo potential diagnostic technique for cancer imaging. This technique undersamples the distribution of specific cancer biomarkers within an MR image as well as changes in the temporal dimension and subsequently reconstructs the missing data. This technique has been

Compressed sensing magnetic resonance spectroscopic imaging (MRSI) is a noninvasive and in vivo potential diagnostic technique for cancer imaging. This technique undersamples the distribution of specific cancer biomarkers within an MR image as well as changes in the temporal dimension and subsequently reconstructs the missing data. This technique has been shown to retain a high level of fidelity even with an acceleration factor of 5. Currently there exist several different scanner types that each have their separate analytical methods in MATLAB. A graphical user interface (GUI) was created to facilitate a single computing platform for these different scanner types in order to improve the ease and efficiency with which researchers and clinicians interact with this technique. A GUI was successfully created for both prospective and retrospective MRSI data analysis. This GUI retained the original high fidelity of the reconstruction technique and gave the user the ability to load data, load reference images, display intensity maps, display spectra mosaics, generate a mask, display the mask, display kspace and save the corresponding spectra, reconstruction, and mask files. Parallelization of the reconstruction algorithm was explored but implementation was ultimately unsuccessful. Future work could consist of integrating this parallelization method, adding intensity overlay functionality and improving aesthetics.
ContributorsLammers, Luke Michael (Author) / Kodibagkar, Vikram (Thesis director) / Hu, Harry (Committee member) / Harrington Bioengineering Program (Contributor) / Barrett, The Honors College (Contributor)
Created2016-05
135102-Thumbnail Image.png
Description
Magnetic resonance imaging (MRI) of changes in metabolic activity in tumors and metabolic abnormalities can provide a window to understanding the complex behavior of malignant tumors. Both diagnostics and treatment options can be improved through the further comprehension of the processes that contribute to tumor malignancy and growth. By detecting

Magnetic resonance imaging (MRI) of changes in metabolic activity in tumors and metabolic abnormalities can provide a window to understanding the complex behavior of malignant tumors. Both diagnostics and treatment options can be improved through the further comprehension of the processes that contribute to tumor malignancy and growth. By detecting and disturbing this activity through personalized treatments, it is the hope to provide better diagnostics and care to patients. Experimenting with multicellular tumor spheroids (MCTS) allows for a rapid, inexpensive and convenient solution to studying multiple in vitro tumors. High quality magnetic resonance images of small samples, such as spheroid, however, are difficult to achieve with current radio frequency coils. In addition, in order for the information provided by these scans to accurately represent the interactions and metabolic activity in vivo, there is a need for a perfused vascular network. A perfused vascular network has the potential to improve metabolic realism and particle transport within a tumor spheroid. By creating a more life-like cancer model and allowing the progressive imaging of metabolic functions of such small samples, a better, more efficient mode of studying metabolic activity in cancer can be created and research efforts can expand. The progress described in this paper attempts to address both of these current shortcomings of metabolic cancer research and offers potential solutions, while acknowledging the potential of future work to improve cancer research with MCTS.
ContributorsTobey, John Paul (Author) / Kodibagkar, Vikram (Thesis director) / Sadleir, Rosalind (Committee member) / Barrett, The Honors College (Contributor)
Created2016-12
171984-Thumbnail Image.png
Description
Electrical stimulation of the human peripheral nervous system can be a powerful tool to treat various medical conditions and provide insight into nervous system processes. A critical challenge for many applications is to selectively activate neurons that have the desired effect while avoiding the activation of neurons that produce side

Electrical stimulation of the human peripheral nervous system can be a powerful tool to treat various medical conditions and provide insight into nervous system processes. A critical challenge for many applications is to selectively activate neurons that have the desired effect while avoiding the activation of neurons that produce side effects. To stimulate peripheral fibers, the longitudinal intrafascicular electrode (LIFE) targets small groups of fibers inside the fascicle using low-amplitude pulses and is well-suited for chronic use. This work aims to understand better the ability to use intrafascicular stimulation with LIFEs to activate small groups of neurons within a fascicle selectively.A hybrid workflow was developed to simulate: 1) the production/propagation of the electric field induced by the stimulation pulse and 2) the effect of the electric field on fiber activation (recruitment). To create efficient and robust strategies for the selective recruitment of axons, recognizing the effect of each parameter on their recruitment and activation pattern is essential. Thus, using this hybrid workflow, the effects of various factors such as fascicular anatomy, electrode parameters, and stimulation pulse parameters on recruitment have been characterized, and the sensitivity of the recruitment patterns to these parameters has been explored. Results demonstrated the potential advantages of specific stimulation strategies and the sensitivity of recruitment patterns to electrode placement and tissue properties. For example, it is demonstrated: the significant effect of endoneurium conductivities on threshold levels; that a configuration with a LIFE as a local ground can be used to deselect its surrounding axons; the advantages of changing the delay between pulses in dual monopolar stimulation in targeting different axons clusters and increasing the activation frequency of some axons; how monopolar and bipolar configurations can be used to enhance spatial selectivity; the effect of longitudinal displacement of axons, electrode length and electrode movement on the recruitment and the activation pattern. In summary, this work forms the foundation for developing stimulation strategies to enhance the selectivity that can be achieved with intrafascicular stimulation.
ContributorsRouhani, Morteza (Author) / Abbas, James J (Thesis advisor) / Crook, Sharon M (Thesis advisor) / Baer, Steven M (Committee member) / Sadleir, Rosalind (Committee member) / Gardner, Carl (Committee member) / Arizona State University (Publisher)
Created2022
190947-Thumbnail Image.png
Description
Non-invasive visualization of the trigeminal nerve through advanced MR sequences and methods like tractography is important for studying anatomical and microstructural changes due to pathology like trigeminal neuralgia (TN), facial dystonia, multiple sclerosis, and for surgical pre-planning. The use of specific anatomical markers from CT, MPRAGE and cranial nerve imaging

Non-invasive visualization of the trigeminal nerve through advanced MR sequences and methods like tractography is important for studying anatomical and microstructural changes due to pathology like trigeminal neuralgia (TN), facial dystonia, multiple sclerosis, and for surgical pre-planning. The use of specific anatomical markers from CT, MPRAGE and cranial nerve imaging (CRANI) sequences, enabled successful tractography of patient-specific trajectory of the frontal, nasociliary, infraorbital, and mandibular nerve branches extending beyond the cisternal brain stem region and leading to the face. Performance of MPRAGE sequence together with the advanced T2-weighted CRANI sequence with and without a gadolinium contrast agent, was studied to characterize identification efficiency in smaller nerve structures in the extremities. A large FOV nerve visualization exam inclusive of the anatomy of all trigeminal nerve distal branches can be obtained within an acquisition time of 20 minutes using pre-contrast CRANI and MPRAGE. Post-processing with MPR and MIP images improved nerve visualization.Transcranial electrical stimulation techniques (TES) have been used for the treatment of multiple neurodegenerative diseases. These techniques involve placing electrodes on the scalp with multiple peripheral branches of the trigeminal nerve crossing directly under that may be stimulated. This was studied through hybrid computational realistic axon models. These models also facilitated studying the effects of electrode drift during experiments on the recruitment of peripheral nerves. An optimal point of lowest threshold was found while displacing the nerve horizontally i.e., the activation thresholds of both myelinated and unmyelinated axons increased when the electrodes were displaced medially and decreased to a certain extend when the electrodes were displaced laterally, after which further lateral displacement led to increase of thresholds. Inclusion of unmyelinated axons in the modeling provided the capability of finding maximum stimulation amplitude below which side effects like pain sensation may be avoided. In the case of F3 – F4 electrode montage the maximum amplitude was 2.39 mA and in case of RS – LS montage the maximum amplitude was 2.44 mA. Such modeling studies may be useful for personalization of TES devices for finding optimal positioning of electrodes with respect to target and stimulation amplitude range that minimizes side effects.
ContributorsSahu, Sulagna (Author) / Sadleir, Rosalind (Thesis advisor) / Tillery, Stephen H (Committee member) / Crook, Sharon (Committee member) / Beeman, Scott (Committee member) / Abbas, James (Committee member) / Arizona State University (Publisher)
Created2023
190929-Thumbnail Image.png
Description
Magnetic resonance imaging (MRI) is the most powerful instrument for imaging anatomical structures. One of the most essential components of the MRI scanner is a radiofrequency (RF) coil. It induces resonant phenomena and receives the resonated RF signal from the body. Then, the signal is computed and reconstructed for MR

Magnetic resonance imaging (MRI) is the most powerful instrument for imaging anatomical structures. One of the most essential components of the MRI scanner is a radiofrequency (RF) coil. It induces resonant phenomena and receives the resonated RF signal from the body. Then, the signal is computed and reconstructed for MR images. Therefore, improving image quality by increasing the receiver's (Rx) efficiency is always remarkable. This research introduces a flexible and stretchable receive RF coil embedded in a dielectric-loaded material. Recent studies show that the adaptable coil can improve imaging quality by flexing and stretching to fit well with the sample's surface, reducing the spatial distance between the load and the coil. High permittivity dielectric material positioned between the coil and phantom was known to increase the RF field distribution's efficiency significantly. Recent studies integrating the high dielectric material with the coil show a significant improvement in signal-to-noise ratio (SNR), which can improve the overall efficiency of the coil. Previous research also introduced new elastic dielectric material, which shows improvement in uniformity when incorporated with an RF coil. Combining the adaptable RF coil with the elastic dielectric material has the potential to enhance the coil's performance further. The flexible dielectric material's limitations and unknown interaction with the coil pose a challenge. Thus, each component was integrated into a simple loop coil step-by-step, which allowed for experimentation and evaluation of the performance of each part. The mechanical performance was tested manually. The introduced coil is highly flexible and can stretch up to 20% of its original length in one direction. The electrical performance was evaluated in simulations and experiments on a 9.4T MRI scanner compared to conventional RF coils.
ContributorsHerabut, Chavalchart (Author) / Sohn, SungMin (Thesis advisor) / Sadleir, Rosalind (Committee member) / Beeman, Scott (Committee member) / Arizona State University (Publisher)
Created2023
190904-Thumbnail Image.png
Description
Allogeneic islet transplantation has the potential to reverse Type 1 Diabetes in patients. However, limitations such as chronic immunosuppression, islet donor numbers, and islet survival post-transplantation prevent the widespread application of allogeneic islet transplantation as the treatment of choice. Macroencapsulation devices have been widely used in allogeneic islet transplantation due

Allogeneic islet transplantation has the potential to reverse Type 1 Diabetes in patients. However, limitations such as chronic immunosuppression, islet donor numbers, and islet survival post-transplantation prevent the widespread application of allogeneic islet transplantation as the treatment of choice. Macroencapsulation devices have been widely used in allogeneic islet transplantation due to their capability to shield transplanted cells from the immune system as well as provide a supportive environment for cell viability, but macroencapsulation devices face oxygen transport challenges as their geometry increases from preclinical to clinical scales. The goal of this work is to generate complex 3D hydrogel macroencapsulation devices with sufficient oxygen transport to support encapsulated cell survival and generate these devices in a way that is accessible in the clinic as well as scaled manufacturing. A 3D-printed injection mold has been developed to generate hydrogel-based cell encapsulation devices with spiral geometries. The spiral geometry of the macroencapsulation device facilitates greater oxygen transport throughout the whole device resulting in improved islet function in vivo in a syngeneic rat model. A computational model of the oxygen concentration within macroencapsulation devices, validated by in vitro analysis, predicts that cells and islets maintain a greater viability and function in the spiral macroencapsulation device. To further validate the computational model, pO2 Reporter Composite Hydrogels (PORCH) are engineered to enable spatiotemporal measurement of oxygen tension within macroencapsulation devices using the Proton Imaging of Siloxanes to map Tissue Oxygenation Levels (PISTOL) magnetic resonance imaging approach. Overall, a macroencapsulation device geometry designed via computational modeling of device oxygen gradients and validated with magnetic resonance (MR) oximetry imaging enhances islet function and survival for islet transplantation.
ContributorsEmerson, Amy (Author) / Weaver, Jessica (Thesis advisor) / Kodibagkar, Vikram (Committee member) / Sadleir, Rosalind (Committee member) / Stabenfeldt, Sarah (Committee member) / Wang, Kuei-Chun (Committee member) / Arizona State University (Publisher)
Created2023
189326-Thumbnail Image.png
Description
Over the past 20 years, the fields of synthetic biology and synthetic biosystems engineering have grown into mature disciplines, leading to significant breakthroughs in cancer research, diagnostics, cell-based medicines, biochemical production, etc. Application of mathematical modelling to biological and biochemical systems have not only given great insight into how these

Over the past 20 years, the fields of synthetic biology and synthetic biosystems engineering have grown into mature disciplines, leading to significant breakthroughs in cancer research, diagnostics, cell-based medicines, biochemical production, etc. Application of mathematical modelling to biological and biochemical systems have not only given great insight into how these systems function, but also have lent enough predictive power to aid in the forward-engineering of synthetic constructs. However, progress has been impeded by several modes of context-dependence unique to biological and biochemical systems that are not seen in traditional engineering disciplines, resulting in the need for lengthy design-build-test cycles before functional prototypes are generated.In this work, two of these universal modes of context dependence – resource competition and growth feedback –their effects on synthetic gene circuits and potential control mechanisms, are studied and characterized. Results demonstrate that a novel competitive control architecture can be utilized to mitigate the effects of winner-take-all resource competition (a form of context dependence where distinct gene modules influence each other by competing over a shared pool of transcriptional/translational resources) in synthetic gene circuits and restore circuits to their intended function. Application of the fluctuation-dissipation theorem and rigorous stochastic simulations demonstrate that realistic resource constraints present in cells at the transcriptional and translational levels influence noise in gene circuits in a nonmonotonic fashion, either increasing or decreasing noise depending on the transcriptional/translational capacity. Growth feedback on the other hand links circuit function to cellular growth rate via increased protein dilution rate during exponential growth phase. This in turn can result in the collapse of bistable gene circuits as the accelerated dilution rate forces switches in a high stable state to fall to a low stable state. Mathematical modelling and experimental data demonstrate that application of repressive links can insulate sensitive parts of gene circuits against growth-fluctuations and can in turn increase the robustness of multistable circuits in growth contexts. The results presented in this work aid in the accumulation of understanding of biological and biochemical context dependence, and corresponding control strategies and design principles engineers can utilize to mitigate these effects.
ContributorsStone, Austin (Author) / Tian, Xiao-jun (Thesis advisor) / Wang, Xiao (Committee member) / Smith, Barbara (Committee member) / Kuang, Yang (Committee member) / Cheng, Albert (Committee member) / Arizona State University (Publisher)
Created2023