In this thesis, an issue is post at the beginning, that there is limited experience in connecting a battery analytical model with a battery circuit model. Then it describes the process of creating a new battery circuit model which is referred to as the kinetic battery model. During this process,

In this thesis, an issue is post at the beginning, that there is limited experience in connecting a battery analytical model with a battery circuit model. Then it describes the process of creating a new battery circuit model which is referred to as the kinetic battery model. During this process, a new general equation is derived. The original equation in the kinetic battery model is only valid at a constant current rate, while the new equation can be used for not only constant current but also linear or nonlinear current. Following the new equation, a circuit representation is built based on the kinetic battery model. Then, by matching the two sets of differential equations of the two models together, the ability to connect the analytical model with the battery circuit model is found. To verify the new battery circuit model is built correctly, the new circuit model is implemented into PSpice simulation software to test the charging performance with constant current, and Matlab/Simulink is also employed to simulate a realistic battery charging process with two-stage charging method. The results have shown the new circuit model is available to be used in realistic scenarios. And because the kinetic battery model can describe different types of rechargeable batteries, the new circuit model is also capable to be used for various battery types.
ContributorsKong, Dexinghui (Author) / Holbert, Keith E. (Thesis advisor) / Karady, George G. (Committee member) / Ayyanar, Raja (Committee member) / Arizona State University (Publisher)
Created2012
154180-Thumbnail Image.png
Description
Underground transmission cables in power systems are less likely to experience electrical faults, however, resulting outage times are much greater in the event that a failure does occur. Unlike overhead lines, underground cables are not self-healing from flashover events. The faulted section must be located and repaired before the line

Underground transmission cables in power systems are less likely to experience electrical faults, however, resulting outage times are much greater in the event that a failure does occur. Unlike overhead lines, underground cables are not self-healing from flashover events. The faulted section must be located and repaired before the line can be put back into service. Since this will often require excavation of the underground duct bank, the procedure to repair the faulted section is both costly and time consuming. These added complications are the prime motivators for developing accurate and reliable ratings for underground cable circuits.

This work will review the methods by which power ratings, or ampacity, for underground cables are determined and then evaluate those ratings by making comparison with measured data taken from an underground 69 kV cable, which is part of the Salt River Project (SRP) power subtransmission system. The process of acquiring, installing, and commissioning the temperature monitoring system is covered in detail as well. The collected data are also used to evaluate typical assumptions made when determining underground cable ratings such as cable hot-spot location and ambient temperatures.

Analysis results show that the commonly made assumption that the deepest portion of an underground power cable installation will be the hot-spot location does not always hold true. It is shown that distributed cable temperature measurements can be used to locate the proper line segment to be used for cable ampacity calculations.
ContributorsStowers, Travis (Author) / Tylavsky, Daniel (Thesis advisor) / Karady, George G. (Committee member) / Holbert, Keith E. (Committee member) / Arizona State University (Publisher)
Created2015
153935-Thumbnail Image.png
Description
Clock generation and distribution are essential to CMOS microchips, providing synchronization to external devices and between internal sequential logic. Clocks in microprocessors are highly vulnerable to single event effects and designing reliable energy efficient clock networks for mission critical applications is a major challenge. This dissertation studies the basics of

Clock generation and distribution are essential to CMOS microchips, providing synchronization to external devices and between internal sequential logic. Clocks in microprocessors are highly vulnerable to single event effects and designing reliable energy efficient clock networks for mission critical applications is a major challenge. This dissertation studies the basics of radiation hardening, essentials of clock design and impact of particle strikes on clocks in detail and presents design techniques for hardening complete clock systems in digital ICs.

Since the sequential elements play a key role in deciding the robustness of any clocking strategy, hardened-by-design implementations of triple-mode redundant (TMR) pulse clocked latches and physical design methodologies for using TMR master-slave flip-flops in application specific ICs (ASICs) are proposed. A novel temporal pulse clocked latch design for low power radiation hardened applications is also proposed. Techniques for designing custom RHBD clock distribution networks (clock spines) and ASIC clock trees for a radiation hardened microprocessor using standard CAD tools are presented. A framework for analyzing the vulnerabilities of clock trees in general, and study the parameters that contribute the most to the tree’s failure, including impact on controlled latches is provided. This is then used to design an integrated temporally redundant clock tree and pulse clocked flip-flop based clocking scheme that is robust to single event transients (SETs) and single event upsets (SEUs). Subsequently, designing robust clock delay lines for use in double data rate (DDRx) memory applications is studied in detail. Several modules of the proposed radiation hardened all-digital delay locked loop are designed and studied. Many of the circuits proposed in this entire body of work have been implemented and tested on a standard low-power 90-nm process.
ContributorsChellappa, Srivatsan (Author) / Clark, Lawrence T (Thesis advisor) / Holbert, Keith E. (Committee member) / Cao, Yu (Committee member) / Ogras, Umit Y. (Committee member) / Arizona State University (Publisher)
Created2015
155927-Thumbnail Image.png
Description
The growth of energy demands in recent years has been increasing faster than the expansion of transmission facility construction. This tendency cooperating with the continuous investing on the renewable energy resources drives the research, development, and construction of HVDC projects to create a more reliable, affordable, and environmentally friendly power

The growth of energy demands in recent years has been increasing faster than the expansion of transmission facility construction. This tendency cooperating with the continuous investing on the renewable energy resources drives the research, development, and construction of HVDC projects to create a more reliable, affordable, and environmentally friendly power grid.

Constructing the hybrid AC-HVDC grid is a significant move in the development of the HVDC techniques; the form of dc system is evolving from the point-to-point stand-alone dc links to the embedded HVDC system and the multi-terminal HVDC (MTDC) system. The MTDC is a solution for the renewable energy interconnections, and the MTDC grids can improve the power system reliability, flexibility in economic dispatches, and converter/cable utilizing efficiencies.

The dissertation reviews the HVDC technologies, discusses the stability issues regarding the ac and HVDC connections, proposes a novel power oscillation control strategy to improve system stability, and develops a nonlinear voltage droop control strategy for the MTDC grid.

To verify the effectiveness the proposed power oscillation control strategy, a long distance paralleled AC-HVDC transmission test system is employed. Based on the PSCAD/EMTDC platform simulation results, the proposed power oscillation control strategy can improve the system dynamic performance and attenuate the power oscillations effectively.

To validate the nonlinear voltage droop control strategy, three droop controls schemes are designed according to the proposed nonlinear voltage droop control design procedures. These control schemes are tested in a hybrid AC-MTDC system. The hybrid AC-MTDC system, which is first proposed in this dissertation, consists of two ac grids, two wind farms and a five-terminal HVDC grid connecting them. Simulation studies are performed in the PSCAD/EMTDC platform. According to the simulation results, all the three design schemes have their unique salient features.
ContributorsYu, Jicheng (Author) / Karady, George G. (Thesis advisor, Committee member) / Qin, Jiangchao (Thesis advisor, Committee member) / Ayyanar, Raja (Committee member) / Holbert, Keith E. (Committee member) / Lei, Qin (Committee member) / Arizona State University (Publisher)
Created2017
155986-Thumbnail Image.png
Description
In this work a comparison has been made between the predictions from the models using both the present theory for the underground cable temperature prediction and the CYMCAP application and the field measurements to determine which, if any, models are capable of predicting the temperature and hotspot locations in an

In this work a comparison has been made between the predictions from the models using both the present theory for the underground cable temperature prediction and the CYMCAP application and the field measurements to determine which, if any, models are capable of predicting the temperature and hotspot locations in an installation where the power cable is not embedded with the optical fibers and, therefore, where the cable temperatures must be inferred from the temperature measurements made in nearby spare ducts. The temperature measurements were collected from the underground 69 kV cable at the Brandow-Pickrell installation, which is a part of Salt River Project’s power sub-transmission system. The model development and the results are explained in detail. Results from the model developed have been compared and the factors affecting the cable temperature are highlighted.

Once the models were developed, it was observed that the earth surface temperature above the installation, solar radiation and other external factors such as underlying water lines, drain pipes, etc. play a key role in heating up or cooling down the power cables. It was also determined that the hotspot location in the power cable in the main duct was the same as the hotspot location in the spare duct inside the same installation.

It was also observed that the CYMCAP model had its limitations when the earth surface temperature variations were modeled in the software as the software only allows the earth’s ambient temperature to be modeled as a constant; further, results from the MATLAB model were more in line with the present theory of underground power cable temperature prediction. However, simulation results from both the MATLAB and CYMCAP model showed deviation from the measured data. It was also observed that the spare duct temperatures in this particular underground installation seemed to be affected by external factors such as solar radiation, underlying water lines, gas lines etc. which cannot be modeled in CYMCAP.
ContributorsSharma, Aman (Author) / Tylavsky, Daniel J (Thesis advisor) / Holbert, Keith E. (Committee member) / Qin, Jiangchao (Committee member) / Arizona State University (Publisher)
Created2017
156714-Thumbnail Image.png
Description
Alternative sources of power generation interconnected at the transmission level have witnessed an increase in investment in the last few years. On the other hand, when the power systems are being operated close to their limits, power system operators and engineers face the challenge of ensuring a safe and reliable

Alternative sources of power generation interconnected at the transmission level have witnessed an increase in investment in the last few years. On the other hand, when the power systems are being operated close to their limits, power system operators and engineers face the challenge of ensuring a safe and reliable supply of electricity. In such a scenario, the reliability of the transmission system is crucial as it ensures secure transfer of uninterrupted power from the generating sources to the load centers. This thesis is aimed at ensuring the reliability of the transmission system from two perspectives. First, this work monitors power system disturbances such as unintentional islanding to ensure prompt detection and implementation of restorative actions and thus, minimizes the extent of damage. Secondly, it investigates power system disturbances such as transmission line outages through reliability evaluation and outage analysis in order to prevent reoccurrence of similar failures.

In this thesis, a passive Wide Area Measurement System (WAMS) based islanding detection scheme called Cumulative Sum of Change in Voltage Phase Angle Difference (CUSPAD) is proposed and tested on a modified 18 bus test system and a modified IEEE 118 bus system with various wind energy penetration levels. Comparative analysis between accuracies of the proposed approach and the conventional relative angle difference approach in presence of measurement errors indicate a superior performance of the former. Results obtained from the proposed approach also reveal that power system disturbances such as unintentional island formations are accurately detected in wind integrated transmission systems.

Quantitative evaluation of the transmission system reliability aids in the assessment of the existing system performance. Further, post-mortem analysis of failures is an important step in minimizing recurrent failures. Reliability evaluation and outage analysis of transmission line outages carried out in this thesis have revealed chronological trends in the system performance. A new index called Outage Impact Index (OII) is also been proposed which can identify and prioritize outages based on their severity. This would serve as a baselining index for assessing and monitoring future transmission system performances and will facilitate implementation of reliability improvement measures if found necessary.
ContributorsBarkakati, Meghna (Author) / Pal, Anamitra (Thesis advisor) / Holbert, Keith E. (Committee member) / Weng, Yang (Committee member) / Arizona State University (Publisher)
Created2018
156908-Thumbnail Image.png
Description
This work investigates the effects of ionizing radiation and displacement damage on the retention of state, DC programming, and neuromorphic pulsed programming of Ag-Ge30Se70 conductive bridging random access memory (CBRAM) devices. The results show that CBRAM devices are susceptible to both environments. An observable degradation in electrical response due to

This work investigates the effects of ionizing radiation and displacement damage on the retention of state, DC programming, and neuromorphic pulsed programming of Ag-Ge30Se70 conductive bridging random access memory (CBRAM) devices. The results show that CBRAM devices are susceptible to both environments. An observable degradation in electrical response due to total ionizing dose (TID) is shown during neuromorphic pulsed programming at TID below 1 Mrad using Cobalt-60. DC cycling in a 14 MeV neutron environment showed a collapse of the high resistance state (HRS) and low resistance state (LRS) programming window after a fluence of 4.9x10^{12} n/cm^2, demonstrating the CBRAM can fail in a displacement damage environment. Heavy ion exposure during retention testing and DC cycling, showed that failures to programming occurred at approximately the same threshold, indicating that the failure mechanism for the two types of tests may be the same. The dose received due to ionizing electronic interactions and non-ionizing kinetic interactions, was calculated for each ion species at the fluence of failure. TID values appear to be the most correlated, indicating that TID effects may be the dominate failure mechanism in a combined environment, though it is currently unclear as to how the displacement damage also contributes to the response. An analysis of material effects due to TID has indicated that radiation damage can limit the migration of Ag+ ions. The reduction in ion current density can explain several of the effects observed in CBRAM while in the LRS.
ContributorsTaggart, Jennifer L (Author) / Barnaby, Hugh J (Thesis advisor) / Kozicki, Michael N (Committee member) / Holbert, Keith E. (Committee member) / Yu, Shimeng (Committee member) / Arizona State University (Publisher)
Created2018
156921-Thumbnail Image.png
Description
Transmission line parameters play an important role in state estimation, dynamic line rating, and fault analysis. Because of this, several methods have been proposed in the literature for line parameter estimation, especially using synchrophasor data. However, success of most prior research has been demonstrated using purely synthetic data. A synthetic

Transmission line parameters play an important role in state estimation, dynamic line rating, and fault analysis. Because of this, several methods have been proposed in the literature for line parameter estimation, especially using synchrophasor data. However, success of most prior research has been demonstrated using purely synthetic data. A synthetic dataset does not have the problems encountered with real data, such as invariance of measurements and realistic field noise. Therefore, the algorithms developed using synthetic datasets may not be as effective when used in practice. On the other hand, the true values of the line parameters are unknown and therefore the algorithms cannot be directly implemented on real data. A multi-stage test procedure is developed in this work to circumvent this problem.

In this thesis, two popular algorithms, namely, moving-window total least squares (MWTLS) and recursive Kalman filter (RKF) are applied on real data in multiple stages. In the first stage, the algorithms are tested on a purely synthetic dataset. This is followed by testing done on pseudo-synthetic datasets generated using real PMU data. In the final stage, the algorithms are implemented on the real PMU data obtained from a local utility. The results show that in the context of the given problem, RKF has better performance than MWTLS. Furthermore, to improve the performance of RKF on real data, ASPEN data are used to calculate the initial estimates. The estimation results show that the RKF algorithm can reliably estimate the sequence impedances, using ASPEN data as a starting condition. The estimation procedure is repeated over different time periods and the corresponding results are presented.

Finally, the significance of data drop-outs and its impact on the use of parameter estimates for real-time power system applications, such as state estimation and dynamic line rating, is discussed. To address the problem (of data drop-outs), an auto regressive integrated moving average (ARIMA) model is implemented. The ability of this model to predict the variations in sequence impedances is demonstrated.
ContributorsMansani, Prashanth Kumar (Author) / Pal, Anamitra (Thesis advisor) / Holbert, Keith E. (Committee member) / Tylavsky, Daniel (Committee member) / Arizona State University (Publisher)
Created2018
153876-Thumbnail Image.png
Description
For a (N+1)-bus power system, possibly 2N solutions exists. One of these solutions

is known as the high-voltage (HV) solution or operable solution. The rest of the solutions

are the low-voltage (LV), or large-angle, solutions.

In this report, a recently developed non-iterative algorithm for solving the power-

flow (PF) problem using the holomorphic embedding

For a (N+1)-bus power system, possibly 2N solutions exists. One of these solutions

is known as the high-voltage (HV) solution or operable solution. The rest of the solutions

are the low-voltage (LV), or large-angle, solutions.

In this report, a recently developed non-iterative algorithm for solving the power-

flow (PF) problem using the holomorphic embedding (HE) method is shown as

being capable of finding the HV solution, while avoiding converging to LV solutions

nearby which is a drawback to all other iterative solutions. The HE method provides a

novel non-iterative procedure to solve the PF problems by eliminating the

non-convergence and initial-estimate dependency issues appeared in the traditional

iterative methods. The detailed implementation of the HE method is discussed in the

report.

While published work focuses mainly on finding the HV PF solution, modified

holomorphically embedded formulations are proposed in this report to find the

LV/large-angle solutions of the PF problem. It is theoretically proven that the proposed

method is guaranteed to find a total number of 2N solutions to the PF problem

and if no solution exists, the algorithm is guaranteed to indicate such by the oscillations

in the maximal analytic continuation of the coefficients of the voltage power series

obtained.

After presenting the derivation of the LV/large-angle formulations for both PQ

and PV buses, numerical tests on the five-, seven- and 14-bus systems are conducted

to find all the solutions of the system of nonlinear PF equations for those systems using

the proposed HE method.

After completing the derivation to find all the PF solutions using the HE method, it

is shown that the proposed HE method can be used to find only the of interest PF solutions

(i.e. type-1 PF solutions with one positive real-part eigenvalue in the Jacobian

matrix), with a proper algorithm developed. The closet unstable equilibrium point

(UEP), one of the type-1 UEP’s, can be obtained by the proposed HE method with

limited dynamic models included.

The numerical performance as well as the robustness of the proposed HE method is

investigated and presented by implementing the algorithm on the problematic cases and

large-scale power system.
ContributorsMine, Yō (Author) / Tylavsky, Daniel (Thesis advisor) / Armbruster, Dieter (Committee member) / Holbert, Keith E. (Committee member) / Sankar, Lalitha (Committee member) / Vittal, Vijay (Committee member) / Undrill, John (Committee member) / Arizona State University (Publisher)
Created2015
153606-Thumbnail Image.png
Description
Non-volatile memory (NVM) has become a staple in the everyday life of consumers. NVM manifests inside cell phones, laptops, and most recently, wearable tech such as smart watches. NAND Flash has been an excellent solution to conditions requiring fast, compact NVM. Current technology nodes are nearing the physical limits of

Non-volatile memory (NVM) has become a staple in the everyday life of consumers. NVM manifests inside cell phones, laptops, and most recently, wearable tech such as smart watches. NAND Flash has been an excellent solution to conditions requiring fast, compact NVM. Current technology nodes are nearing the physical limits of scaling, preventing flash from improving. To combat the limitations of flash and to appease consumer demand for progressively faster and denser NVM, new technologies are needed. One possible candidate for the replacement of NAND Flash is programmable metallization cells (PMC). PMC are a type of resistive memory, meaning that they do not rely on charge storage to maintain a logic state. Depending on their application, it is possible that devices containing NVM will be exposed to harsh radiation environments. As part of the process for developing a novel memory technology, it is important to characterize the effects irradiation has on the functionality of the devices.

This thesis characterizes the effects that ionizing γ-ray irradiation has on the retention of the programmed resistive state of a PMC. The PMC devices tested used Ge30Se70 doped with Ag as the solid electrolyte layer and were fabricated by the thesis author in a Class 100 clean room. Individual device tiles were wire bonded into ceramic packages and tested in a biased and floating contact scenario.

The first scenario presented shows that PMC devices are capable of retaining their programmed state up to the maximum exposed total ionizing dose (TID) of 3.1 Mrad(Si). In this first scenario, the contacts of the PMC devices were left floating during exposure. The second scenario tested shows that the PMC devices are capable of retaining their state until the maximum TID of 10.1 Mrad(Si) was reached. The contacts in the second scenario were biased, with a 50 mV read voltage applied to the anode contact. Analysis of the results show that Ge30Se70 PMC are ionizing radiation tolerant and can retain a programmed state to a higher TID than NAND Flash memory.
ContributorsTaggart, Jennifer Lynn (Author) / Barnaby, Hugh (Thesis advisor) / Kozicki, Michael (Committee member) / Holbert, Keith E. (Committee member) / Arizona State University (Publisher)
Created2015