Matching Items (10)
Filtering by

Clear all filters

Description
Advances in software and applications continue to demand advances in memory. The ideal memory would be non-volatile and have maximal capacity, speed, retention time, endurance, and radiation hardness while also having minimal physical size, energy usage, and cost. The programmable metallization cell (PMC) is an emerging memory technology that is

Advances in software and applications continue to demand advances in memory. The ideal memory would be non-volatile and have maximal capacity, speed, retention time, endurance, and radiation hardness while also having minimal physical size, energy usage, and cost. The programmable metallization cell (PMC) is an emerging memory technology that is likely to surpass flash memory in all the listed ideal memory characteristics. A comprehensive physics-based model is needed to fully understand PMC operation and aid in design optimization. With the intent of advancing the PMC modeling effort, this thesis presents two simulation models for the PMC. The first model is a finite element model based on Silvaco Atlas finite element analysis software. Limitations of the software are identified that make this model inconsistent with the operating mechanism of the PMC. The second model is a physics-based numerical model developed for the PMC. This model is successful in matching data measured from a chalcogenide glass PMC designed and manufactured at ASU. Matched operating characteristics observable in the current and resistance vs. voltage data include the OFF/ON resistances and write/erase and electrodeposition voltage thresholds. Multilevel programming is also explained and demonstrated with the numerical model. The numerical model has already proven useful by revealing some information presented about the operation and characteristics of the PMC.
ContributorsOleksy, David Ryan (Author) / Barnaby, Hugh J (Thesis advisor) / Kozicki, Michael N (Committee member) / Edwards, Arthur H (Committee member) / Arizona State University (Publisher)
Created2013
151954-Thumbnail Image.png
Description
Low Power, High Speed Analog to Digital Converters continues to remain one of the major building blocks for modern communication systems. Due to continuing trend of the aggressive scaling of the MOS devices, the susceptibility of most of the deep-sub micron CMOS technologies to the ionizing radiation has decreased over

Low Power, High Speed Analog to Digital Converters continues to remain one of the major building blocks for modern communication systems. Due to continuing trend of the aggressive scaling of the MOS devices, the susceptibility of most of the deep-sub micron CMOS technologies to the ionizing radiation has decreased over the period of time. When electronic circuits fabricated in these CMOS technologies are exposed to ionizing radiations, considerable change in the performance of circuits can be seen over a period of time. The change in the performance can be quantified in terms of decreasing linearity of the circuit which directly relates to the resolution of the circuit. Analog to Digital Converter is one of the most critical blocks of any electronic circuitry sent to space. The degradation in the performance of an Analog to Digital Converter due to radiation effects can jeopardize many research programs related to space. These radiation effects can completely hamper the working of a circuit. This thesis discusses the effects of Ionizing radiation on an 11 bit 325 MSPS pipeline ADC. The ADC is exposed to different doses of radiation and performance is compared.
ContributorsVashisth, Siddharth (Author) / Barnaby, Hugh J (Thesis advisor) / Bakkaloglu, Bertan (Committee member) / Mikkola, Esko (Committee member) / Arizona State University (Publisher)
Created2013
152388-Thumbnail Image.png
Description
Microprocessors are the processing heart of any digital system and are central to all the technological advancements of the age including space exploration and monitoring. The demands of space exploration require a special class of microprocessors called radiation hardened microprocessors which are less susceptible to radiation present outside the earth's

Microprocessors are the processing heart of any digital system and are central to all the technological advancements of the age including space exploration and monitoring. The demands of space exploration require a special class of microprocessors called radiation hardened microprocessors which are less susceptible to radiation present outside the earth's atmosphere, in other words their functioning is not disrupted even in presence of disruptive radiation. The presence of these particles forces the designers to come up with design techniques at circuit and chip levels to alleviate the errors which can be encountered in the functioning of microprocessors. Microprocessor evolution has been very rapid in terms of performance but the same cannot be said about its rad-hard counterpart. With the total data processing capability overall increasing rapidly, the clear lack of performance of the processors manifests as a bottleneck in any processing system. To design high performance rad-hard microprocessors designers have to overcome difficult design problems at various design stages i.e. Architecture, Synthesis, Floorplanning, Optimization, routing and analysis all the while maintaining circuit radiation hardness. The reference design `HERMES' is targeted at 90nm IBM G process and is expected to reach 500Mhz which is twice as fast any processor currently available. Chapter 1 talks about the mechanisms of radiation effects which cause upsets and degradation to the functioning of digital circuits. Chapter 2 gives a brief description of the components which are used in the design and are part of the consistent efforts at ASUVLSI lab culminating in this chip level implementation of the design. Chapter 3 explains the basic digital design ASIC flow and the changes made to it leading to a rad-hard specific ASIC flow used in implementing this chip. Chapter 4 talks about the triple mode redundant (TMR) specific flow which is used in the block implementation, delineating the challenges faced and the solutions proposed to make the flow work. Chapter 5 explains the challenges faced and solutions arrived at while using the top-level flow described in chapter 3. Chapter 6 puts together the results and analyzes the design in terms of basic integrated circuit design constraints.
ContributorsRamamurthy, Chandarasekaran (Author) / Clark, Lawrence T (Thesis advisor) / Holbert, Keith E. (Committee member) / Barnaby, Hugh J (Committee member) / Mayhew, David (Committee member) / Arizona State University (Publisher)
Created2013
150389-Thumbnail Image.png
Description
Radiation-induced gain degradation in bipolar devices is considered to be the primary threat to linear bipolar circuits operating in the space environment. The damage is primarily caused by charged particles trapped in the Earth's magnetosphere, the solar wind, and cosmic rays. This constant radiation exposure leads to early end-of-life expectancies

Radiation-induced gain degradation in bipolar devices is considered to be the primary threat to linear bipolar circuits operating in the space environment. The damage is primarily caused by charged particles trapped in the Earth's magnetosphere, the solar wind, and cosmic rays. This constant radiation exposure leads to early end-of-life expectancies for many electronic parts. Exposure to ionizing radiation increases the density of oxide and interfacial defects in bipolar oxides leading to an increase in base current in bipolar junction transistors. Radiation-induced excess base current is the primary cause of current gain degradation. Analysis of base current response can enable the measurement of defects generated by radiation exposure. In addition to radiation, the space environment is also characterized by extreme temperature fluctuations. Temperature, like radiation, also has a very strong impact on base current. Thus, a technique for separating the effects of radiation from thermal effects is necessary in order to accurately measure radiation-induced damage in space. This thesis focuses on the extraction of radiation damage in lateral PNP bipolar junction transistors and the space environment. It also describes the measurement techniques used and provides a quantitative analysis methodology for separating radiation and thermal effects on the bipolar base current.
ContributorsCampola, Michael J (Author) / Barnaby, Hugh J (Thesis advisor) / Holbert, Keith E. (Committee member) / Vasileska, Dragica (Committee member) / Arizona State University (Publisher)
Created2011
156033-Thumbnail Image.png
Description
A modeling platform for predicting total ionizing dose (TID) and dose rate response of commercial commercial-off-the-shelf (COTS) linear bipolar circuits and technologies is introduced. Tasks associated with the modeling platform involve the development of model to predict the excess current response in a bipolar transistor given inputs of interface (NIT)

A modeling platform for predicting total ionizing dose (TID) and dose rate response of commercial commercial-off-the-shelf (COTS) linear bipolar circuits and technologies is introduced. Tasks associated with the modeling platform involve the development of model to predict the excess current response in a bipolar transistor given inputs of interface (NIT) and oxide defects (NOT) which are caused by ionizing radiation exposure. Existing models that attempt to predict this excess base current response are derived and discussed in detail. An improved model is proposed which modifies the existing model and incorporates the impact of charged interface trap defects on radiation-induced excess base current. The improved accuracy of the new model in predicting excess base current response in lateral PNP (LPNP) is then verified with Technology Computer Aided Design (TCAD) simulations. Finally, experimental data and compared with the improved and existing model calculations.
ContributorsTolleson, Blayne S. (Author) / Barnaby, Hugh J (Thesis advisor) / Gonzalez-Velo, Yago (Committee member) / Kitchen, Jennifer (Committee member) / Arizona State University (Publisher)
Created2017
154946-Thumbnail Image.png
Description
High speed image sensors are used as a diagnostic tool to analyze high speed processes for industrial, automotive, defense and biomedical application. The high fame rate of these sensors, capture a series of images that enables the viewer to understand and analyze the high speed phenomena. However, the pixel readout

High speed image sensors are used as a diagnostic tool to analyze high speed processes for industrial, automotive, defense and biomedical application. The high fame rate of these sensors, capture a series of images that enables the viewer to understand and analyze the high speed phenomena. However, the pixel readout circuits designed for these sensors with a high frame rate (100fps to 1 Mfps) have a very low fill factor which are less than 58%. For high speed operation, the exposure time is less and (or) the light intensity incident on the image sensor is less. This makes it difficult for the sensor to detect faint light signals and gives a lower limit on the signal levels being detected by the sensor. Moreover, the leakage paths in the pixel readout circuit also sets a limit on the signal level being detected. Therefore, the fill factor of the pixel should be maximized and the leakage currents in the readout circuits should be minimized.

This thesis work presents the design of the pixel readout circuit suitable for high speed and low light imaging application. The circuit is an improvement to the 6T pixel readout architecture. The designed readout circuit minimizes the leakage currents in the circuit and detects light producing a signal level of 350µV at the cathode of the photodiode. A novel layout technique is used for the pixel, which improves the fill factor of the pixel to 64.625%. The read out circuit designed is an integral part of high speed image sensor, which is fabricated using a 0.18 µm CMOS technology with the die size of 3.1mm x 3.4 mm, the pixel size of 20µm x 20 µm, number of pixel of 96 x 96 and four 10-bit pipelined ADC’s. The image sensor achieves a high frame rate of 10508 fps and readout speed of 96 M pixels / sec.
ContributorsZol, Akshay (Author) / Barnaby, Hugh J (Thesis advisor) / Mikkola, Esko O (Committee member) / Kitchen, Jennifer N (Committee member) / Arizona State University (Publisher)
Created2016
149389-Thumbnail Image.png
Description
Implantable medical device technology is commonly used by doctors for disease management, aiding to improve patient quality of life. However, it is possible for these devices to be exposed to ionizing radiation during various medical therapeutic and diagnostic activities while implanted. This commands that these devices remain fully operational during,

Implantable medical device technology is commonly used by doctors for disease management, aiding to improve patient quality of life. However, it is possible for these devices to be exposed to ionizing radiation during various medical therapeutic and diagnostic activities while implanted. This commands that these devices remain fully operational during, and long after, radiation exposure. Many implantable medical devices employ standard commercial complementary metal-oxide-semiconductor (CMOS) processes for integrated circuit (IC) development, which have been shown to degrade with radiation exposure. This necessitates that device manufacturers study the effects of ionizing radiation on their products, and work to mitigate those effects to maintain a high standard of reliability. Mitigation can be completed through targeted radiation hardening by design (RHBD) techniques as not to infringe on the device operational specifications. This thesis details a complete radiation analysis methodology that can be implemented to examine the effects of ionizing radiation on an IC as part of RHBD efforts. The methodology is put into practice to determine the failure mechanism in a charge pump circuit, common in many of today's implantable pacemaker designs, as a case study. Charge pump irradiation data shows a reduction of circuit output voltage with applied dose. Through testing of individual test devices, the response is identified as parasitic inter-device leakage caused by trapped oxide charge buildup in the isolation oxides. A library of compact models is generated to represent isolation oxide parasitics based on test structure data along with 2-Dimensional structure simulation results. The original charge pump schematic is then back-annotated with transistors representative of the parasitic. Inclusion of the parasitic devices in schematic allows for simulation of the entire circuit, accounting for possible parasitic devices activated by radiation exposure. By selecting a compact model for the parasitics generated at a specific dose, the compete circuit response is then simulated at the defined dose. The reduction of circuit output voltage with dose is then re-created in a radiation-enabled simulation validating the analysis methodology.
ContributorsSchlenvogt, Garrett (Author) / Barnaby, Hugh J (Thesis advisor) / Goodnick, Stephen (Committee member) / Vasileska, Dragica (Committee member) / Arizona State University (Publisher)
Created2010
157467-Thumbnail Image.png
Description
ABSTRACT

Programmable metallization cell (PMC) technology uses the mechanism of metal ion transport in solid electrolytes and electrochemical redox reactions to form metallic electrodeposits. When a positive bias is applied from anode to cathode, atoms at the anode are oxidized to ions and dissolve in the solid electrolyte. They

ABSTRACT

Programmable metallization cell (PMC) technology uses the mechanism of metal ion transport in solid electrolytes and electrochemical redox reactions to form metallic electrodeposits. When a positive bias is applied from anode to cathode, atoms at the anode are oxidized to ions and dissolve in the solid electrolyte. They travel to the cathode under the influence of an electric field, where they are reduced to form electrodeposits. These electrodeposits are filamentary in nature and grow in different patterns. Devices that make use of the principle of filament growth have applications in memory, RF switching, and hardware security.

The solid electrolyte under investigation is tungsten trioxide with copper deposited on top. For a standard PMC, these layers are heated in a convection oven to dope the electrolyte. Once the heating process is completed, electrodes are deposited on top of the electrolyte and biased to grow the filaments. What is investigated is the rate of dendritic growth to applied field on the PMC and the composition of the electrolyte. Also investigated are modified three-terminal PMC capacitance change devices. These devices have a buried sensing electrode that senses the increasing capacitance as the filaments grow and increase the upper electrode area.

The rate of dendritic growth in the tungsten trioxide and copper electrolyte of different chemistries and applied field to the PMC devices is the important parameter. The rate of dendritic growth is related to the change of capacitance. Through sensing the change in capacitance over time the modified PMC device will function as an odometer device that can be attached to chips. The attachment of these devices to chips, help in preventing illegal recycling of old chips by marking those chips as old. This will prevent would-be attackers from inserting modified chips in systems that will enable them to by-pass any software security precautions.
ContributorsKrishnan, Anand (Author) / Kozicki, Michael N (Thesis advisor) / Barnaby, Hugh J (Committee member) / Gonzalez-Velo, Yago (Committee member) / Arizona State University (Publisher)
Created2019
187462-Thumbnail Image.png
Description
Linear bipolar circuits, designed with bipolar junction transistors (BJTs), are particularly vulnerable to the effects of space radiation. These circuits, which are usually commercial off-the-shelf (COTS) components, typically exhibit Enhanced Low Dose Rate Sensitivity (ELDRS), which is characterized by the enhancement of degradation when parts are exposed to radiation at

Linear bipolar circuits, designed with bipolar junction transistors (BJTs), are particularly vulnerable to the effects of space radiation. These circuits, which are usually commercial off-the-shelf (COTS) components, typically exhibit Enhanced Low Dose Rate Sensitivity (ELDRS), which is characterized by the enhancement of degradation when parts are exposed to radiation at low dose rates as compared to high dose rates. This phenomenon poses significant problems for the qualification of bipolar parts for use in low dose rate environments, such as most Earth orbits. ELDRS in BJTs has been well-documented in ground-based experiments; however, the effects of low dose rate irradiation on bipolar transistors manufactured in an integrated linear process had never been characterized in space - until the ELDRS experiment was launched in June 2019. The ELDRS instrument measures changes in the active collector and base currents in 24 lateral PNP (LPNP) BJTs on eight packaged die (three BJTs per die). Sixteen of the 24 BJTs are gated, while eight are standard, un-gated LPNPs. Device Under Test (DUT) and measurement variables include oxide thickness, passivation layer, packaging conditions, and gate voltage. This thesis reports the results obtained after more than 20 months of space flight in a highly elliptical Earth orbit. These results demonstrate that this category of bipolar devices is susceptible to low dose rate exposures and therefore exhibits the ELDRS effect in an actual space environment. This thesis also assess the impact of packaging variables on radiation response and examines one of the major causes behind radiation degradation, interface traps. An understanding of radiation effects in real space environments is critical for future missions that use these low-cost COTS bipolar technologies, making these results highly relevant for the satellite community.
ContributorsBenedetto, Adalin (Author) / Barnaby, Hugh J (Thesis advisor) / Goodnick, Stephen (Committee member) / Sanchez, Ivan (Committee member) / Arizona State University (Publisher)
Created2023
153200-Thumbnail Image.png
Description
As photons, electrons, and neutrons traverse a medium, they impart their energy in ways that are analytically difficult to describe. Monte Carlo methods provide valuable insight into understanding this behavior, especially when the radiation source or environment is too complex to simplify. This research investigates simulating various radiation sources using

As photons, electrons, and neutrons traverse a medium, they impart their energy in ways that are analytically difficult to describe. Monte Carlo methods provide valuable insight into understanding this behavior, especially when the radiation source or environment is too complex to simplify. This research investigates simulating various radiation sources using the Monte Carlo N-Particle (MCNP) transport code, characterizing their impact on various materials, and comparing the simulation results to general theory and measurements.

A total of five sources were of interest: two photon sources of different incident particle energies (3.83 eV and 1.25 MeV), two electron sources also of different energies (30 keV and 100 keV), and a californium-252 (Cf-252) spontaneous fission neutron source. Lateral and vertical programmable metallization cells (PMCs) were developed by other researchers for exposure to these photon and electron sources, so simplified PMC models were implemented in MCNP to estimate the doses and fluences. Dose rates measured around the neutron source and the predicted maximum activity of activation foils exposed to the neutrons were determined using MCNP and compared to experimental results obtained from gamma-ray spectroscopy.

The analytical fluence calculations for the photon and electron cases agreed with MCNP results, and differences are due to MCNP considering particle movements that hand calculations do not. Doses for the photon cases agreed between the analytical and simulated results, while the electron cases differed by a factor of up to 4.8. Physical dose rate measurements taken from the neutron source agreed with MCNP within the 10% tolerance of the measurement device. The activity results had a percent error of up to 50%, which suggests a need to further evaluate the spectroscopy setup.
ContributorsBowler, Herbert (Author) / Holbert, Keith E. (Thesis advisor) / Barnaby, Hugh J (Committee member) / Clark, Lawrence T (Committee member) / Arizona State University (Publisher)
Created2014