Matching Items (23)
Filtering by

Clear all filters

150274-Thumbnail Image.png
Description
Voltage Control Oscillator (VCO) is one of the most critical blocks in Phase Lock Loops (PLLs). LC-tank VCOs have a superior phase noise performance, however they require bulky passive resonators and often calibration architectures to overcome their limited tuning range. Ring oscillator (RO) based VCOs are attractive for digital technology

Voltage Control Oscillator (VCO) is one of the most critical blocks in Phase Lock Loops (PLLs). LC-tank VCOs have a superior phase noise performance, however they require bulky passive resonators and often calibration architectures to overcome their limited tuning range. Ring oscillator (RO) based VCOs are attractive for digital technology applications owing to their ease of integration, small die area and scalability in deep submicron processes. However, due to their supply sensitivity and poor phase noise performance, they have limited use in applications demanding low phase noise floor, such as wireless or optical transceivers. Particularly, out-of-band phase noise of RO-based PLLs is dominated by RO performance, which cannot be suppressed by the loop gain, impairing RF receiver's sensitivity or BER of optical clock-data recovery circuits. Wide loop bandwidth PLLs can overcome RO noise penalty, however, they suffer from increased in-band noise due to reference clock, phase-detector and charge-pump. The RO phase noise is determined by the noise coming from active devices, supply, ground and substrate. The authors adopt an auxiliary circuit with inverse delay sensitivity to supply noise, which compensates for the delay variation of inverter cells. Feed-forward noise-cancelling architecture that improves phase noise characteristic of RO based PLLs is presented. The proposed circuit dynamically attenuates RO phase noise contribution outside the PLL bandwidth, or in a preferred band. The implemented noise-cancelling loop potentially enables application of RO based PLL for demanding frequency synthesizers applications, such as optical links or high-speed serial I/Os.
ContributorsMin, Seungkee (Author) / Kiaei, Sayfe (Thesis advisor) / Bakkaloglu, Bertan (Committee member) / Ozev, Sule (Committee member) / Towe, Bruce (Committee member) / Arizona State University (Publisher)
Created2011
151656-Thumbnail Image.png
Description
Image resolution limits the extent to which zooming enhances clarity, restricts the size digital photographs can be printed at, and, in the context of medical images, can prevent a diagnosis. Interpolation is the supplementing of known data with estimated values based on a function or model involving some or all

Image resolution limits the extent to which zooming enhances clarity, restricts the size digital photographs can be printed at, and, in the context of medical images, can prevent a diagnosis. Interpolation is the supplementing of known data with estimated values based on a function or model involving some or all of the known samples. The selection of the contributing data points and the specifics of how they are used to define the interpolated values influences how effectively the interpolation algorithm is able to estimate the underlying, continuous signal. The main contributions of this dissertation are three fold: 1) Reframing edge-directed interpolation of a single image as an intensity-based registration problem. 2) Providing an analytical framework for intensity-based registration using control grid constraints. 3) Quantitative assessment of the new, single-image enlargement algorithm based on analytical intensity-based registration. In addition to single image resizing, the new methods and analytical approaches were extended to address a wide range of applications including volumetric (multi-slice) image interpolation, video deinterlacing, motion detection, and atmospheric distortion correction. Overall, the new approaches generate results that more accurately reflect the underlying signals than less computationally demanding approaches and with lower processing requirements and fewer restrictions than methods with comparable accuracy.
ContributorsZwart, Christine M. (Author) / Frakes, David H (Thesis advisor) / Karam, Lina (Committee member) / Kodibagkar, Vikram (Committee member) / Spanias, Andreas (Committee member) / Towe, Bruce (Committee member) / Arizona State University (Publisher)
Created2013
Description
This research investigated using impedance as a minimally invasive oral cancer-screening tool by modeling healthy and diseased tissue. This research developed an ultra-structurally based tissue model for oral mucosa that is versatile enough to be easily modified to mimic the passive electrical impedance responses of multiple benign and cancerous tissue

This research investigated using impedance as a minimally invasive oral cancer-screening tool by modeling healthy and diseased tissue. This research developed an ultra-structurally based tissue model for oral mucosa that is versatile enough to be easily modified to mimic the passive electrical impedance responses of multiple benign and cancerous tissue types. This new model provides answers to biologically meaningful questions related to the impedance response of healthy and diseased tissues. This model breaks away from the old empirical top down "black box" Thèvinin equivalent model. The new tissue model developed here was created from a bottom up perspective resulting in a model that is analogous to having a "Transparent Box" where each network element relating to a specific structural component is known. This new model was developed starting with sub cellular ultra-structural components such as membranes, proteins and electrolytes. These components formed the basic network elements and topology of the organelles. The organelle networks combine to form the cell networks. The cell networks combine to make networks of cell layers and the cell layers were combined into tissue networks. This produced the complete "Transparent Box" model for normal tissue. This normal tissue model was modified for disease based on the ultra-structural pathology of each disease. The diseased tissues evaluated include cancers type one through type three; necrotic-inflammation, hyperkeratosis and the compound condition of hyperkeratosis over cancer type two. The impedance responses for each of the disease were compared side by side with the response of normal healthy tissue. Comparative evidence from the models showed the structural changes in cancer produce a unique identifiable impedance "finger print." The evaluation of the "Transparent Box" model for normal tissues and diseased tissues show clear support for using comparative impedance measurements as a clinical tool for oral cancer screening.
ContributorsPelletier, Peter Robert (Author) / Kozicki, Michael (Thesis advisor) / Towe, Bruce (Committee member) / Saraniti, Marco (Committee member) / Goryll, Michael (Committee member) / Arizona State University (Publisher)
Created2012
150437-Thumbnail Image.png
Description
Magnetic Resonance Imaging (MRI) is limited in speed and resolution by the inherently low Signal to Noise Ratio (SNR) of the underlying signal. Advances in sampling efficiency are required to support future improvements in scan time and resolution. SNR efficiency is improved by sampling data for a larger proportion of

Magnetic Resonance Imaging (MRI) is limited in speed and resolution by the inherently low Signal to Noise Ratio (SNR) of the underlying signal. Advances in sampling efficiency are required to support future improvements in scan time and resolution. SNR efficiency is improved by sampling data for a larger proportion of total imaging time. This is challenging as these acquisitions are typically subject to artifacts such as blurring and distortions. The current work proposes a set of tools to help with the creation of different types of SNR efficient scans. An SNR efficient pulse sequence providing diffusion imaging data with full brain coverage and minimal distortion is first introduced. The proposed method acquires single-shot, low resolution image slabs which are then combined to reconstruct the full volume. An iterative deblurring algorithm allowing the lengthening of spiral SPoiled GRadient echo (SPGR) acquisition windows in the presence of rapidly varying off-resonance fields is then presented. Finally, an efficient and practical way of collecting 3D reformatted data is proposed. This method constitutes a good tradeoff between 2D and 3D neuroimaging in terms of scan time and data presentation. These schemes increased the SNR efficiency of currently existing methods and constitute key enablers for the development of SNR efficient MRI.
ContributorsAboussouan, Eric (Author) / Frakes, David (Thesis advisor) / Pipe, James (Thesis advisor) / Debbins, Joseph (Committee member) / Towe, Bruce (Committee member) / Arizona State University (Publisher)
Created2011
Description
The action/adventure game Grad School: HGH is the final, extended version of a BME Prototyping class project in which the goal was to produce a zombie-themed game that teaches biomedical engineering concepts. The gameplay provides fast paced, exciting, and mildly addicting rooms that the player must battle and survive through,

The action/adventure game Grad School: HGH is the final, extended version of a BME Prototyping class project in which the goal was to produce a zombie-themed game that teaches biomedical engineering concepts. The gameplay provides fast paced, exciting, and mildly addicting rooms that the player must battle and survive through, followed by an engineering puzzle that must be solved in order to advance to the next room. The objective of this project was to introduce the core concepts of BME to prospective students, rather than attempt to teach an entire BME curriculum. Based on user testing at various phases in the project, we concluded that the gameplay was engaging enough to keep most users' interest through the educational puzzles, and the potential for expanding this project to reach an even greater audience is vast.
ContributorsNitescu, George (Co-author) / Medawar, Alexandre (Co-author) / Spano, Mark (Thesis director) / LaBelle, Jeffrey (Committee member) / Guiang, Kristoffer (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor)
Created2014-05
Description
Volume depletion can lead to migraines, dizziness, and significant decreases in a subject's ability to physically perform. A major cause of volume depletion is dehydration, or loss in fluids due to an imbalance in fluid intake to fluid excretion. Because proper levels of hydration are necessary in order to maintain

Volume depletion can lead to migraines, dizziness, and significant decreases in a subject's ability to physically perform. A major cause of volume depletion is dehydration, or loss in fluids due to an imbalance in fluid intake to fluid excretion. Because proper levels of hydration are necessary in order to maintain both short and long term health, the ability to monitor hydration levels is growing in clinical demand. Although devices capable of monitoring hydration level exist, these devices are expensive, invasive, or inaccurate and do not offer a continuous mode of measurement. The ideal hydration monitor for consumer use needs to be characterized by its portability, affordability, and accuracy. Also, this device would need to be noninvasive and offer continuous hydration monitoring in order to accurately assess fluctuations in hydration data throughout a specified time period. One particular method for hydration monitoring that fits the majority of these criteria is known as bioelectric impedance analysis (BIA). Although current devices using BIA do not provide acceptable levels of accuracy, portability, or continuity in data collection, BIA could potentially be modified to fit many, if not all, desired customer specifications. The analysis presented here assesses the viability of using BIA as a new standard in hydration level measurement. The analysis uses data collected from 22 subjects using an existing device that employs BIA. A regression derived for estimating TBW based on the parameters of age, weight, height, sex, and impedance is presented. Using impedance data collected for each subject, a regression was also derived for estimating impedance based on the factors of age, weight, height, and sex. The derived regression was then used to calculate a new impedance value for each subject, and these new impedance values were used to estimate TBW. Through a paired-t test between the TBW values derived by using the direct measurements versus the calculated measurements of impedance, the two samples were found to be comparable. Considerations for BIA as a noninvasive measurement of hydration are discussed.
ContributorsTenorio, Jorge Antonio (Author) / LaBelle, Jeffrey (Thesis director) / Pizziconi, Vincent (Committee member) / Spano, Mark (Committee member) / Barrett, The Honors College (Contributor) / W. P. Carey School of Business (Contributor) / Harrington Bioengineering Program (Contributor)
Created2013-05
Description

With the recent rise in opioid overdose and death1<br/><br/>, chronic opioid therapy (COT) programs using<br/>Center of Disease Control (CDC) guidelines have been implemented across the United States8<br/>.<br/>Primary care clinicians at Mayo Clinic initiated a COT program in September of 2017, during the<br/>use of Cerner Electronic Health Record (EHR) system. Study

With the recent rise in opioid overdose and death1<br/><br/>, chronic opioid therapy (COT) programs using<br/>Center of Disease Control (CDC) guidelines have been implemented across the United States8<br/>.<br/>Primary care clinicians at Mayo Clinic initiated a COT program in September of 2017, during the<br/>use of Cerner Electronic Health Record (EHR) system. Study metrics included provider<br/>satisfaction and perceptions regarding opioid prescription. Mayo Clinic transitioned its EHR<br/>system from Cerner to Epic in October 2018. This study aims to understand if provider perceptions<br/>about COT changed after the EHR transition and the reasons underlying those perceptions.

ContributorsPonnapalli, Sravya (Author) / Murcko, Anita (Thesis director) / Wallace, Mark (Committee member) / College of Health Solutions (Contributor) / Barrett, The Honors College (Contributor)
Created2021-05
136262-Thumbnail Image.png
Description
The Larynx plays a pivotal role in our ability to breathe and to speak. It is in our best interest to continue improving the status of tissue regeneration concerning the larynx so that patient voice quality of life can be less hindered in the face of laryngeal cancers and diseases.

The Larynx plays a pivotal role in our ability to breathe and to speak. It is in our best interest to continue improving the status of tissue regeneration concerning the larynx so that patient voice quality of life can be less hindered in the face of laryngeal cancers and diseases. Modern technology can allow us to use CT scans for both diagnosis and treatment. This medical imaging can be converted into three-dimensional patient specific models that are actualized through 3D printing. These implants improve upon the current state of the art because they can be produced in a timely manner, are developed with materials and methods ensuring their biocompatibility, and follow architectures and geometries best suited for the patient to improve their voice quality of life. Additionally they should be able to allow patient speech in the case of partial laryngectomies where the arytenoid has been removed by acting as a permanent vocal fold This treatment process for laryngectomies aligns itself with personalized medicine by targeting its geometry based on that of the patient. Technologies and manufacturing processes utilized to produce them are accessible and could all be used within the clinical space. The life-saving implant required for the laryngectomy healing and recovery process can be ready to implant for the patient within a few days of imaging them.
ContributorsBarry, Colin Patrick (Author) / Pizziconi, Vincent (Thesis director) / Lott, David (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor)
Created2015-05
132519-Thumbnail Image.png
Description
Abstract: The delivery of a drug or gene payload inside an individual neuron has been highly sought after and studied as a means of treating a large variety of neurological diseases and disorders such as cancer and Alzheimer’s. Current technology for these applications remains imperfect particularly with respect to

Abstract: The delivery of a drug or gene payload inside an individual neuron has been highly sought after and studied as a means of treating a large variety of neurological diseases and disorders such as cancer and Alzheimer’s. Current technology for these applications remains imperfect particularly with respect to matters of precision and cell viability. Thus, the use of MEMS (micro electro mechanical systems) based systems have become more prevalent in order to conduct these processes with higher precision and automation. Penetrating these specific cells while also maintaining their structural integrity during the process, remain as two major hurdles still being explored today. Electrical stimulation has been used to drive the delivery of a payload at the microscale but to do so with a voltage that keeps the neuron viable is imperative. In order to find a means for optimizing the voltage and ejection of the payload while maintaining cell viability, the goal of this project is to explore the use of pulsed waveforms for driving the delivery. In doing so, lower to moderate voltage amplitudes may potentially be used while also avoiding hydrolysis of the cell. This study was done by ejecting dye dextran from glass micropipettes with an agar and artificial seawater well using both DC and pulsed waveforms. Successful ejection of the payload was achieved and confirmed using fluorescent microscopy. While the methods used for this voltage based delivery require further optimization, the successful ejection utilizing pulsed voltages suggest that this may lead to an improved technique for MEMS based delivery of payloads into single cells in the future.
ContributorsStamm, Steven Jeffrey (Author) / Muthuswamy, Jitendran (Thesis director) / Sridharan, Arati (Committee member) / Harrington Bioengineering Program (Contributor, Contributor) / Barrett, The Honors College (Contributor)
Created2019-05
132721-Thumbnail Image.png
Description
Tissue engineering is an emerging field focused on the repair, replacement, and regeneration of damaged tissue. Engineered tissue consists of three factors: cells, biomolecular signals, and a scaffold. Cell-free scaffolds present a unique opportunity to develop highly specific microenvironments with tunable properties. Norbornene-functionalized hyaluronic acid (NorHA) hydrogels provide spatial control

Tissue engineering is an emerging field focused on the repair, replacement, and regeneration of damaged tissue. Engineered tissue consists of three factors: cells, biomolecular signals, and a scaffold. Cell-free scaffolds present a unique opportunity to develop highly specific microenvironments with tunable properties. Norbornene-functionalized hyaluronic acid (NorHA) hydrogels provide spatial control over biomolecule binding through a photopolymerization process. With this, biomimetic gradients can be produced to model a variety of tissue interfaces. To produce these patterns, a gradient mechanism was developed to function in tandem with a syringe pump. A conversion equation was derived to calculate a panel speed from the volumetric flow rate setting on the pump. Seven speeds were used to produce fluorophore gradients on the surface of NorHA hydrogels to assess changes in the length and slope of the gradient. The results indicated a strong positive linear correlation between the speed of the panel and the length of the gradient as well as a strong negative correlation between the speed of the panel and the slope of the gradient. Additionally, the mechanism was able to successfully produce several other types of gradients including multiregional, dual, and triregional.
ContributorsSogge, Amber (Author) / Holloway, Julianne (Thesis director) / Stabenfeldt, Sarah (Committee member) / Fumasi, Fallon (Committee member) / Harrington Bioengineering Program (Contributor, Contributor) / Barrett, The Honors College (Contributor)
Created2019-05