One major issue that surgeons face during closed body cavity surgery is fogging of the lens surfaces. The cloudy and opaque lens surface caused by water vapor present in closed body cavities forces the surgeon to repeatedly remove the endoscope, wipe it, and reinsert it back into the patient. This

One major issue that surgeons face during closed body cavity surgery is fogging of the lens surfaces. The cloudy and opaque lens surface caused by water vapor present in closed body cavities forces the surgeon to repeatedly remove the endoscope, wipe it, and reinsert it back into the patient. This presents several risks such as increased surgery time, greater scarring, and an increased chance of infection. In order to address this issue, the development of the Thin Fluid Film Device (TFFD™) VitreOx™ aims to render the lens surface hydrophilic, whereas it is typically hydrophobic. By creating a hydrophilic polymeric nanomesh, the 3-D water droplets can be trapped to lie flatter, thus resulting in a flatter 2-D sheeting effect. The light can no longer be refracted at different angles off of the 3-dimensional water beads, thus eliminating the opacity of the lens surface.
Two animal trials were performed involving a rat and two pigs in order to prove the efficacy of VitreOx™ in addition to being compared with competitor, Covidien Clearify. A laparoscopy was performed on each animal, and the length of time that the endoscope took to fog was measured post product application. The results of the optimized animal clinical trials involving two Yucatan pigs showed that the scope treated with Covidien’s Clearify began fogging within 8 minutes and continued to do so for the remained of the surgery, as opposed to the scope with VitreOx™ which remained fog free for the full 90-minute procedure. The results proved the efficacy of our product.
The second part of the thesis aimed to optimize HemoClear™, the blood evacuating TFFD™. This was done by testing a higher concentration of 6 mg/mL fibrinogen as compared to previous work. After conducting an experiment designed to mimic closed-body cavity surgery it was determined that the HemoClear™ eliminated fog 67% of the time and evacuated blood with a success of 83%. Future work aims to continue testing at this concentration with variances in mixing and application technique.
ContributorsSinha, Saloni Agarwal (Author) / Culbertson, Robert (Thesis director) / Herbots, Nicole (Committee member) / Watson, Clarizza (Committee member) / Barrett, The Honors College (Contributor) / Department of Chemistry and Biochemistry (Contributor)
Created2015-05
136337-Thumbnail Image.png
Description
With higher than normal levels of cardiovascular disease, diabetes, obesity, and sexually transmitted diseases within the Deaf community, it is clear that the current level of medical care is failing. This can stem from many different issues, from the mistrust of doctors to the fact that scientific education in the

With higher than normal levels of cardiovascular disease, diabetes, obesity, and sexually transmitted diseases within the Deaf community, it is clear that the current level of medical care is failing. This can stem from many different issues, from the mistrust of doctors to the fact that scientific education in the Deaf community is introduced at a later time in comparison to the hearing population. Similarly, there is a distinct lack of Deaf and hard of hearing medical staff. All of this culminates in the fact that the system needs to change. The addition of more Deaf staff in the medical environment, more staff interpreters, and doctors that have experience with the Deaf community engenders the metamorphosis of this group from unhealthy to healthy. Extra exposure for doctors during clinical rotations to deaf patients as well as training in Deaf Culture will further increase the comfort level of Deaf community members utilizing health services. As a result, the overall state of medical care for the Deaf population will improve with these modifications to the current system.
ContributorsBrar, Serbnoor Singh (Author) / Quinn, Paul (Thesis director) / Howard, Pamela (Committee member) / Barrett, The Honors College (Contributor) / Department of Chemistry and Biochemistry (Contributor)
Created2015-05
136474-Thumbnail Image.png
Description
As the prevalence of childhood obesity in the United States rises, opportunities for children to be physically active become more vital. One opportunity for physical activity involves children walking to and from school. However, children that live in areas with a pedestrian-unfriendly built environment and a low degree of walkability

As the prevalence of childhood obesity in the United States rises, opportunities for children to be physically active become more vital. One opportunity for physical activity involves children walking to and from school. However, children that live in areas with a pedestrian-unfriendly built environment and a low degree of walkability are less likely to be physically active and more likely to be overweight. The purpose of this study was to study walking routes from schools in low-income neighborhoods in Southwestern United States to a local community center. Walking routes from the three study schools (South Mountain High School, Percy Julian Middle School, and Rose Linda Elementary School) were determined by distance, popularity, and the presence of a major thoroughfare. Segments and intersections, which formed the routes, were randomly selected from each school's buffer region. The walking routes as a whole, along with the segments and intersections, were audited and scored using built environment assessments tools: MAPS, PEQI and Walkability Checklist. These scores were utilized to develop interactive mapping tools to visualize the quality of the routes, segments and intersections and identify areas for improvement. Results showed that the routes from Percy Julian to the Kroc Center were, overall, rated higher than routes from the other two schools. The highest scoring route, from the seven routes studied, was route 2 from Percy Julian to the Kroc Center along Broadway Road. South Mountain High School was overall the worst starting point for walking to the Kroc Center as those three walking routes were graded as the least walkable. Possible areas for improvement include installing traffic calming features along major thoroughfares and reducing the perceived risk to pedestrian safety by beautifying the community by planting greenery. Future directions include studying the built environment in South Phoenix communities that surround the Kroc Center.
ContributorsZeien, Justin Lee (Author) / Buman, Matthew (Thesis director) / Hekler, Eric (Committee member) / Fellows, Brian (Committee member) / Barrett, The Honors College (Contributor) / School of Sustainability (Contributor) / Department of Chemistry and Biochemistry (Contributor)
Created2015-05
Description
Background: The American Heart Association has created an Official 2012 Hands-Only CPR Instructional Video that is approximately one minute in length and has been viewed over 600,000 times on YouTube. Objective: To evaluate the video's effectiveness in teaching adolescents aged 12-17 hands-only CPR. Methodology: The study took place in the

Background: The American Heart Association has created an Official 2012 Hands-Only CPR Instructional Video that is approximately one minute in length and has been viewed over 600,000 times on YouTube. Objective: To evaluate the video's effectiveness in teaching adolescents aged 12-17 hands-only CPR. Methodology: The study took place in the Phoenix metropolitan area. Study participants were recruited from high schools, junior high schools and the Tempe Boys & Girls Club. The 100 study participants took a short, four question survey and watched video on either a laptop computer or video projector. Participants were then subjected to a cardiac arrest mock scenario in which they were tested on calling 911, compression rate, compression depth, and hand placement using a Lifeform CPArlene Recording Manikin. In analysis of the data, subjects were separated into four groups: 12-14 year olds (middle school aged) who had previous CPR training (MSG-T), 12-14 year olds with no previous training (MSG-U), 15-17 year olds (high school aged) who had previous training (HSG-T) and 15-17 year olds with no previous training (HSG-U). Results: Every study participant performed hands-only CPR during the mock scenario. Between the two middle school-aged groups, the MSG-U was more likely to call 911 during the mock scenario (P<0.05). There were no significant differences in compression rate and depth between the MSG-U and MSG-T. Between the two high school-aged groups, the HSG-T was more likely to call 911 during the mock scenario (P<0.05). There was no significant difference in compression rate between the HSG-T and HSG-U groups. The HSG-T compressed the chest significantly deeper than the HSG-U group (P<0.05). The HSG-T was the only group to statistically be on par with the AHA recommended 100 compressions/minute (P<0.05). All other groups were significantly below the 100 compressions/minute standard. No groups were statistically on par with the AHA recommended compression depth of two inches. Conclusion: The Official 2012 Hands-Only Instructional Video should not be used as a definitive training tool to teach school-aged adolescents hands-only CPR. This video, as well as other similar training videos, would be useful as introductory tools for children 12-14 years of age or as a refresher for older children who have received previous training.
ContributorsChoppi, Joseph Anthony (Author) / Johnston, Carol (Thesis director) / Hall, Rick (Committee member) / Gross, Toni (Committee member) / Barrett, The Honors College (Contributor) / Department of Chemistry and Biochemistry (Contributor)
Created2013-05
Description
The action/adventure game Grad School: HGH is the final, extended version of a BME Prototyping class project in which the goal was to produce a zombie-themed game that teaches biomedical engineering concepts. The gameplay provides fast paced, exciting, and mildly addicting rooms that the player must battle and survive through,

The action/adventure game Grad School: HGH is the final, extended version of a BME Prototyping class project in which the goal was to produce a zombie-themed game that teaches biomedical engineering concepts. The gameplay provides fast paced, exciting, and mildly addicting rooms that the player must battle and survive through, followed by an engineering puzzle that must be solved in order to advance to the next room. The objective of this project was to introduce the core concepts of BME to prospective students, rather than attempt to teach an entire BME curriculum. Based on user testing at various phases in the project, we concluded that the gameplay was engaging enough to keep most users' interest through the educational puzzles, and the potential for expanding this project to reach an even greater audience is vast.
ContributorsNitescu, George (Co-author) / Medawar, Alexandre (Co-author) / Spano, Mark (Thesis director) / LaBelle, Jeffrey (Committee member) / Guiang, Kristoffer (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor)
Created2014-05
Description
Volume depletion can lead to migraines, dizziness, and significant decreases in a subject's ability to physically perform. A major cause of volume depletion is dehydration, or loss in fluids due to an imbalance in fluid intake to fluid excretion. Because proper levels of hydration are necessary in order to maintain

Volume depletion can lead to migraines, dizziness, and significant decreases in a subject's ability to physically perform. A major cause of volume depletion is dehydration, or loss in fluids due to an imbalance in fluid intake to fluid excretion. Because proper levels of hydration are necessary in order to maintain both short and long term health, the ability to monitor hydration levels is growing in clinical demand. Although devices capable of monitoring hydration level exist, these devices are expensive, invasive, or inaccurate and do not offer a continuous mode of measurement. The ideal hydration monitor for consumer use needs to be characterized by its portability, affordability, and accuracy. Also, this device would need to be noninvasive and offer continuous hydration monitoring in order to accurately assess fluctuations in hydration data throughout a specified time period. One particular method for hydration monitoring that fits the majority of these criteria is known as bioelectric impedance analysis (BIA). Although current devices using BIA do not provide acceptable levels of accuracy, portability, or continuity in data collection, BIA could potentially be modified to fit many, if not all, desired customer specifications. The analysis presented here assesses the viability of using BIA as a new standard in hydration level measurement. The analysis uses data collected from 22 subjects using an existing device that employs BIA. A regression derived for estimating TBW based on the parameters of age, weight, height, sex, and impedance is presented. Using impedance data collected for each subject, a regression was also derived for estimating impedance based on the factors of age, weight, height, and sex. The derived regression was then used to calculate a new impedance value for each subject, and these new impedance values were used to estimate TBW. Through a paired-t test between the TBW values derived by using the direct measurements versus the calculated measurements of impedance, the two samples were found to be comparable. Considerations for BIA as a noninvasive measurement of hydration are discussed.
ContributorsTenorio, Jorge Antonio (Author) / LaBelle, Jeffrey (Thesis director) / Pizziconi, Vincent (Committee member) / Spano, Mark (Committee member) / Barrett, The Honors College (Contributor) / W. P. Carey School of Business (Contributor) / Harrington Bioengineering Program (Contributor)
Created2013-05
136489-Thumbnail Image.png
Description
Exercise is a great boon to both the health of individuals and the national as a whole. Exercise provides a wide range of significant and well established benefits to both physical and psychological health, with many benefits that are still being discovered. The effects of exercise on health are somewhat

Exercise is a great boon to both the health of individuals and the national as a whole. Exercise provides a wide range of significant and well established benefits to both physical and psychological health, with many benefits that are still being discovered. The effects of exercise on health are somewhat unique, as exercise is one of a limited number of ways to improve health that is not harm a reduction strategy, but instead increases health through direct benefit, rather than increasing health by decreasing damage and harm. Support is also given to the proposal that individuals are in best position to determine the intensity of exercise and to choose primary activities to participate in, in order to provide near maximum physical and psychological benefit, with the understanding that frequency of exercise is of the upmost importance for benefit. The accessibility of exercise and the tremendous health benefit of exercise, makes exercise a huge asset in reducing the exorbitant health care spending and improving mediocre health outcomes in this country; a reasonable goal as numerous countries have better health the United States, even though the United States spends the more than any other country on health.
ContributorsRael, Ashur Scott (Author) / Kashiwagi, Dean (Thesis director) / Kashiwagi, Jacob (Committee member) / Barrett, The Honors College (Contributor) / Department of Chemistry and Biochemistry (Contributor) / School of Film, Dance and Theatre (Contributor)
Created2015-05
132519-Thumbnail Image.png
Description
Abstract: The delivery of a drug or gene payload inside an individual neuron has been highly sought after and studied as a means of treating a large variety of neurological diseases and disorders such as cancer and Alzheimer’s. Current technology for these applications remains imperfect particularly with respect to

Abstract: The delivery of a drug or gene payload inside an individual neuron has been highly sought after and studied as a means of treating a large variety of neurological diseases and disorders such as cancer and Alzheimer’s. Current technology for these applications remains imperfect particularly with respect to matters of precision and cell viability. Thus, the use of MEMS (micro electro mechanical systems) based systems have become more prevalent in order to conduct these processes with higher precision and automation. Penetrating these specific cells while also maintaining their structural integrity during the process, remain as two major hurdles still being explored today. Electrical stimulation has been used to drive the delivery of a payload at the microscale but to do so with a voltage that keeps the neuron viable is imperative. In order to find a means for optimizing the voltage and ejection of the payload while maintaining cell viability, the goal of this project is to explore the use of pulsed waveforms for driving the delivery. In doing so, lower to moderate voltage amplitudes may potentially be used while also avoiding hydrolysis of the cell. This study was done by ejecting dye dextran from glass micropipettes with an agar and artificial seawater well using both DC and pulsed waveforms. Successful ejection of the payload was achieved and confirmed using fluorescent microscopy. While the methods used for this voltage based delivery require further optimization, the successful ejection utilizing pulsed voltages suggest that this may lead to an improved technique for MEMS based delivery of payloads into single cells in the future.
ContributorsStamm, Steven Jeffrey (Author) / Muthuswamy, Jitendran (Thesis director) / Sridharan, Arati (Committee member) / Harrington Bioengineering Program (Contributor, Contributor) / Barrett, The Honors College (Contributor)
Created2019-05
132363-Thumbnail Image.png
Description
The dilemma of the lack of prenatal and neonatal healthcare has been prevalent among third world countries for many years. The lack of prenatal healthcare has been shown to have direct links to spontaneous preterm births from which low-birth weight in babies can be a result. The World Health Organization

The dilemma of the lack of prenatal and neonatal healthcare has been prevalent among third world countries for many years. The lack of prenatal healthcare has been shown to have direct links to spontaneous preterm births from which low-birth weight in babies can be a result. The World Health Organization has identified preterm birth as one of the biggest overseen burdens in developing countries.
This study seeks to answer the research questions: What are the major risk factors associated with the lack of prenatal and neonatal healthcare in developing countries? What are potential routes of intervention (ROI) to help these countries? The goal is to analyze the risk factors and determine if there are any ROIs available to minimize potential incidents or accidents associated with complications of preterm birth.
A few potential risk factors include: poverty, a mother’s lack of education, a lack of professional visitation during pregnancy, having a short cervix, and routine use of Ultrasound. This research paper has identified that keeping ultrasound diagnostics to a minimum, seeking professional help during pregnancy, incorporating corticosteroids for preterm births, implementing Kangaroo Mother Care, and Cervical Cerclage are interventions that can reduce preterm births and the associated complications that come with it. We believe that further research, regarding compliance of each of these interventions, would show reduction of preterm births and low birth weight in developing countries.
ContributorsHuapaya, Eduardo Luciano (Author) / Muthuswamy, Jitendran (Thesis director) / Comar, William (Committee member) / Harrington Bioengineering Program (Contributor) / Barrett, The Honors College (Contributor)
Created2019-05
131908-Thumbnail Image.png
Description
The primary goal of this paper is to analyze a tool used for measuring human
development on a global scale. Originally, development within a country was solely judged by the degree of economic growth by way of Gross National Product (GNP) and per capita income. Holistically, GNP measures the total extent

The primary goal of this paper is to analyze a tool used for measuring human
development on a global scale. Originally, development within a country was solely judged by the degree of economic growth by way of Gross National Product (GNP) and per capita income. Holistically, GNP measures the total extent of economic activity of a country’s people within a given time period. (Rutherford, 2012). Critics found several issues with this one-dimensional approach of measuring human development. What failed to be recognized was the distribution of income among the country’s citizens. Higher incomes often favor men within the majority when compared to women and people of minority groups (Feiner & Roberts, 1990). GNP also failed to recognize the social limitations under a government. In other words, are there limitations as to what goods can be bought and who can buy them?
ContributorsSteeley, Emily Anne (Author) / Parmentier, Mary Jane (Thesis director) / Grgich, Traci (Committee member) / Harrington Bioengineering Program (Contributor) / School of Human Evolution & Social Change (Contributor) / Barrett, The Honors College (Contributor)
Created2020-05