The demand for cleaner energy technology is increasing very rapidly. Hence it is
important to increase the eciency and reliability of this emerging clean energy technologies.
This thesis focuses on modeling and reliability of solar micro inverters. In
order to make photovoltaics (PV) cost competitive with traditional energy sources,
the economies of scale have been guiding inverter design in two directions: large,
centralized, utility-scale (500 kW) inverters vs. small, modular, module level (300
W) power electronics (MLPE). MLPE, such as microinverters and DC power optimizers,
oer advantages in safety, system operations and maintenance, energy yield,
and component lifetime due to their smaller size, lower power handling requirements,
and module-level power point tracking and monitoring capability [1]. However, they
suer from two main disadvantages: rst, depending on array topology (especially
the proximity to the PV module), they can be subjected to more extreme environments
(i.e. temperature cycling) during the day, resulting in a negative impact to
reliability; second, since solar installations can have tens of thousands to millions of
modules (and as many MLPE units), it may be dicult or impossible to track and
repair units as they go out of service. Therefore identifying the weak links in this
system is of critical importance to develop more reliable micro inverters.
While an overwhelming majority of time and research has focused on PV module
eciency and reliability, these issues have been largely ignored for the balance
of system components. As a relatively nascent industry, the PV power electronics
industry does not have the extensive, standardized reliability design and testing procedures
that exist in the module industry or other more mature power electronics
industries (e.g. automotive). To do so, the critical components which are at risk and
their impact on the system performance has to be studied. This thesis identies and
addresses some of the issues related to reliability of solar micro inverters.
This thesis presents detailed discussions on various components of solar micro inverter
and their design. A micro inverter with very similar electrical specications in
comparison with commercial micro inverter is modeled in detail and veried. Components
in various stages of micro inverter are listed and their typical failure mechanisms
are reviewed. A detailed FMEA is conducted for a typical micro inverter to identify
the weak links of the system. Based on the S, O and D metrics, risk priority number
(RPN) is calculated to list the critical at-risk components. Degradation of DC bus
capacitor is identied as one the failure mechanism and the degradation model is built
to study its eect on the system performance. The system is tested for surge immunity
using standard ring and combinational surge waveforms as per IEEE 62.41 and
IEC 61000-4-5 standards. All the simulation presented in this thesis is performed
using PLECS simulation software.
important to increase the eciency and reliability of this emerging clean energy technologies.
This thesis focuses on modeling and reliability of solar micro inverters. In
order to make photovoltaics (PV) cost competitive with traditional energy sources,
the economies of scale have been guiding inverter design in two directions: large,
centralized, utility-scale (500 kW) inverters vs. small, modular, module level (300
W) power electronics (MLPE). MLPE, such as microinverters and DC power optimizers,
oer advantages in safety, system operations and maintenance, energy yield,
and component lifetime due to their smaller size, lower power handling requirements,
and module-level power point tracking and monitoring capability [1]. However, they
suer from two main disadvantages: rst, depending on array topology (especially
the proximity to the PV module), they can be subjected to more extreme environments
(i.e. temperature cycling) during the day, resulting in a negative impact to
reliability; second, since solar installations can have tens of thousands to millions of
modules (and as many MLPE units), it may be dicult or impossible to track and
repair units as they go out of service. Therefore identifying the weak links in this
system is of critical importance to develop more reliable micro inverters.
While an overwhelming majority of time and research has focused on PV module
eciency and reliability, these issues have been largely ignored for the balance
of system components. As a relatively nascent industry, the PV power electronics
industry does not have the extensive, standardized reliability design and testing procedures
that exist in the module industry or other more mature power electronics
industries (e.g. automotive). To do so, the critical components which are at risk and
their impact on the system performance has to be studied. This thesis identies and
addresses some of the issues related to reliability of solar micro inverters.
This thesis presents detailed discussions on various components of solar micro inverter
and their design. A micro inverter with very similar electrical specications in
comparison with commercial micro inverter is modeled in detail and veried. Components
in various stages of micro inverter are listed and their typical failure mechanisms
are reviewed. A detailed FMEA is conducted for a typical micro inverter to identify
the weak links of the system. Based on the S, O and D metrics, risk priority number
(RPN) is calculated to list the critical at-risk components. Degradation of DC bus
capacitor is identied as one the failure mechanism and the degradation model is built
to study its eect on the system performance. The system is tested for surge immunity
using standard ring and combinational surge waveforms as per IEEE 62.41 and
IEC 61000-4-5 standards. All the simulation presented in this thesis is performed
using PLECS simulation software.
ContributorsManchanahalli Ranganatha, Arkanatha Sastry (Author) / Ayyanar, Raja (Thesis advisor) / Karady, George G. (Committee member) / Qin, Jiangchao (Committee member) / Arizona State University (Publisher)
Created2015
Description
Overhead high voltage transmission lines are widely used around the world to deliver power to customers because of their low losses and high transmission capability. Well-coordinated insulation systems are capable of withstanding lightning and switching surge voltages. However, flashover is a serious issue to insulation systems, especially if the insulator is covered by a pollution layer. Many experiments in the laboratory have been conducted to investigate this issue. Since most experiments are time-consuming and costly, good mathematical models could contribute to predicting the insulator flashover performance as well as guide the experiments. This dissertation proposes a new statistical model to calculate the flashover probability of insulators under different supply voltages and contamination levels. An insulator model with water particles in the air is simulated to analyze the effects of rain and mist on flashover performance in reality. Additionally, insulator radius and number of sheds affect insulator surface resistivity and leakage distance. These two factors are studied to improve the efficiency of insulator design. This dissertation also discusses the impact of insulator surface hydrophobicity on flashover voltage.
Because arc propagation is a stochastic process, an arc could travel on different paths based on the electric field distribution. Some arc paths jump between insulator sheds instead of travelling along the insulator surfaces. The arc jumping could shorten the leakage distance and intensify the electric field. Therefore, the probabilities of arc jumping at different locations of sheds are also calculated in this dissertation.
The new simulation model is based on numerical electric field calculation and random walk theory. The electric field is calculated by the variable-grid finite difference method. The random walk theory from the Monte Carlo Method is utilized to describe the random propagation process of arc growth. This model will permit insulator engineers to design the reasonable geometry of insulators, to reduce the flashover phenomena under a wide range of operating conditions.
Because arc propagation is a stochastic process, an arc could travel on different paths based on the electric field distribution. Some arc paths jump between insulator sheds instead of travelling along the insulator surfaces. The arc jumping could shorten the leakage distance and intensify the electric field. Therefore, the probabilities of arc jumping at different locations of sheds are also calculated in this dissertation.
The new simulation model is based on numerical electric field calculation and random walk theory. The electric field is calculated by the variable-grid finite difference method. The random walk theory from the Monte Carlo Method is utilized to describe the random propagation process of arc growth. This model will permit insulator engineers to design the reasonable geometry of insulators, to reduce the flashover phenomena under a wide range of operating conditions.
ContributorsHe, Jiahong (Author) / Gorur, Ravi (Thesis advisor) / Ayyanar, Raja (Committee member) / Holbert, Keith E. (Committee member) / Karady, George G. (Committee member) / Arizona State University (Publisher)
Created2016
Description
After a major disturbance, the power system response is highly dependent on protection schemes and system dynamics. Improving power systems situational awareness requires proper and simultaneous modeling of both protection schemes and dynamic characteristics in power systems analysis tools. Historical information and ex-post analysis of blackouts reaffirm the critical role of protective devices in cascading events, thereby confirming the necessity to represent protective functions in transient stability studies. This dissertation is aimed at studying the importance of representing protective relays in power system dynamic studies. Although modeling all of the protective relays within transient stability studies may result in a better estimation of system behavior, representing, updating, and maintaining the protection system data becomes an insurmountable task. Inappropriate or outdated representation of the relays may result in incorrect assessment of the system behavior. This dissertation presents a systematic method to determine essential relays to be modeled in transient stability studies. The desired approach should identify protective relays that are critical for various operating conditions and contingencies. The results of the transient stability studies confirm that modeling only the identified critical protective relays is sufficient to capture system behavior for various operating conditions and precludes the need to model all of the protective relays. Moreover, this dissertation proposes a method that can be implemented to determine the appropriate location of out-of-step blocking relays. During unstable power swings, a generator or group of generators may accelerate or decelerate leading to voltage depression at the electrical center along with generator tripping. This voltage depression may cause protective relay mis-operation and unintentional separation of the system. In order to avoid unintentional islanding, the potentially mis-operating relays should be blocked from tripping with the use of out-of-step blocking schemes. Blocking these mis-operating relays, combined with an appropriate islanding scheme, help avoid a system wide collapse. The proposed method is tested on data from the Western Electricity Coordinating Council. A triple line outage of the California-Oregon Intertie is studied. The results show that the proposed method is able to successfully identify proper locations of out-of-step blocking scheme.
ContributorsHedman, Mojdeh Khorsand (Author) / Vittal, Vijay (Thesis advisor) / Ayyanar, Raja (Committee member) / Pal, Anamitra (Committee member) / Qin, Jiangchao (Committee member) / Arizona State University (Publisher)
Created2017
Description
The constant scaling of supply voltages in state-of-the-art CMOS processes has led to severe limitations for many analog circuit applications. Some CMOS processes have addressed this issue by adding high voltage MOSFETs to their process. Although it can be a completely viable solution, it usually requires a changing of the process flow or adding additional steps, which in turn, leads to an increase in fabrication costs. Si-MESFETs (silicon-metal-semiconductor-field-effect-transistors) from Arizona State University (ASU) on the other hand, have an inherent high voltage capability and can be added to any silicon-on-insulator (SOI) or silicon-on-sapphire (SOS) CMOS process free of cost. This has been proved at five different commercial foundries on technologies ranging from 0.5 to 0.15 μm. Another critical issue facing CMOS processes on insulated substrates is the scaling of the thin silicon channel. Consequently, the future direction of SOI/SOS CMOS transistors may trend away from partially depleted (PD) transistors and towards fully depleted (FD) devices. FD-CMOS are already being implemented in multiple applications due to their very low power capability. Since the FD-CMOS market only figures to grow, it is appropriate that MESFETs also be developed for these processes. The beginning of this thesis will focus on the device aspects of both PD and FD-MESFETs including their layout structure, DC and RF characteristics, and breakdown voltage. The second half will then shift the focus towards implementing both types of MESFETs in an analog circuit application. Aside from their high breakdown ability, MESFETs also feature depletion mode operation, easy to adjust but well controlled threshold voltages, and fT's up to 45 GHz. Those unique characteristics can allow certain designs that were previously difficult to implement or prohibitively expensive using conventional technologies to now be achieved. One such application which benefits is low dropout regulators (LDO). By utilizing an n-channel MESFET as the pass transistor, a LDO featuring very low dropout voltage, fast transient response, and stable operation can be achieved without an external capacitance. With the focus of this thesis being MESFET based LDOs, the device discussion will be mostly tailored towards optimally designing MESFETs for this particular application.
ContributorsLepkowski, William (Author) / Thornton, Trevor (Thesis advisor) / Bakkaloglu, Bertan (Committee member) / Goryll, Michael (Committee member) / Ayyanar, Raja (Committee member) / Arizona State University (Publisher)
Created2010
Description
Energy is one of the wheels on which the modern world runs. Therefore, standards and limits have been devised to maintain the stability and reliability of the power grid. This research shows a simple methodology for increasing the amount of Inverter-based Renewable Generation (IRG), which is also known as Inverter-based Resources (IBR), for that considers the voltage and frequency limits specified by the Western Electricity Coordinating Council (WECC) Transmission Planning (TPL) criteria, and the tie line power flow limits between the area-under-study and its neighbors under contingency conditions. A WECC power flow and dynamic file is analyzed and modified in this research to demonstrate the performance of the methodology. GE's Positive Sequence Load Flow (PSLF) software is used to conduct this research and Python was used to analyze the output data.
The thesis explains in detail how the system with 11% of IRG operated before conducting any adjustments (addition of IRG) and what procedures were modified to make the system run correctly. The adjustments made to the dynamic models are also explained in depth to give a clearer picture of how each adjustment affects the system performance. A list of proposed IRG units along with their locations were provided by SRP, a power utility in Arizona, which were to be integrated into the power flow and dynamic files. In the process of finding the maximum IRG penetration threshold, three sensitivities were also considered, namely, momentary cessation due to low voltages, transmission vs. distribution connected solar generation, and stalling of induction motors. Finally, the thesis discusses how the system reacts to the aforementioned modifications, and how IRG penetration threshold gets adjusted with regards to the different sensitivities applied to the system.
The thesis explains in detail how the system with 11% of IRG operated before conducting any adjustments (addition of IRG) and what procedures were modified to make the system run correctly. The adjustments made to the dynamic models are also explained in depth to give a clearer picture of how each adjustment affects the system performance. A list of proposed IRG units along with their locations were provided by SRP, a power utility in Arizona, which were to be integrated into the power flow and dynamic files. In the process of finding the maximum IRG penetration threshold, three sensitivities were also considered, namely, momentary cessation due to low voltages, transmission vs. distribution connected solar generation, and stalling of induction motors. Finally, the thesis discusses how the system reacts to the aforementioned modifications, and how IRG penetration threshold gets adjusted with regards to the different sensitivities applied to the system.
ContributorsAlbhrani, Hashem A M H S (Author) / Pal, Anamitra (Thesis advisor) / Holbert, Keith E. (Committee member) / Ayyanar, Raja (Committee member) / Arizona State University (Publisher)