156743-Thumbnail Image.png
Description
Measurements of the response of superconducting nanowire single photon detector (SNSPD) devices to changes in various forms of input power can be used for characterization of the devices and for probing device-level physics. Two niobium nitride (NbN) superconducting nanowires developed for use as SNSPD devices are embedded as the inductive

Measurements of the response of superconducting nanowire single photon detector (SNSPD) devices to changes in various forms of input power can be used for characterization of the devices and for probing device-level physics. Two niobium nitride (NbN) superconducting nanowires developed for use as SNSPD devices are embedded as the inductive (L) component in resonant inductor/capacitor (LC) circuits coupled to a microwave transmission line. The capacitors are low loss commercial chip capacitors which limit the internal quality factor of the resonators to approximately $Qi = 170$. The resonator quality factor, approximately $Qr = 23$, is dominated by the coupling to the feedline and limits the detection bandwidth to on the order of 1MHz. In our experiments with this first generation device, we measure the response of the SNSPD devices to changes in thermal and optical power in both the time domain and the frequency domain. Additionally, we explore the non-linear response of the devices to an applied bias current. For these nanowires, we find that the band-gap energy is $\Delta_0 \approx 1.1$meV and that the density of states at the Fermi energy is $N_0 \sim 10^{10}$/eV/$\mu$m$^3$.

We present the results of experimentation with a superconducting nanowire that can be operated in two detection modes: i) as a kinetic inductance detector (KID) or ii) as a single photon detector (SPD). When operated as a KID mode in linear mode, the detectors are AC-biased with tones at their resonant frequencies of 45.85 and 91.81MHz. When operated as an SPD in Geiger mode, the resonators are DC biased through cryogenic bias tees and each photon produces a sharp voltage step followed by a ringdown signal at the resonant frequency of the detector. We show that a high AC bias in KID mode is inferior for photon counting experiments compared to operation in a DC-biased SPD mode due to the small fraction of time spent near the critical current with an AC bias. We find a photon count rate of $\Gamma_{KID} = 150~$photons/s/mA in a critically biased KID mode and a photon count rate of $\Gamma_{SPD} = 10^6~$photons/s/mA in SPD mode.

This dissertation additionally presents simulations of a DC-biased, frequency-multiplexed readout of SNSPD devices in Advanced Design System (ADS), LTspice, and Sonnet. A multiplexing factor of 100 is achievable with a total count rate of $>5$MHz. This readout could enable a 10000-pixel array for astronomy or quantum communications. Finally, we present a prototype array design based on lumped element components. An early implementation of the array is presented with 16 pixels in the frequency range of 74.9 to 161MHz. We find good agreement between simulation and experimental data in both the time domain and the frequency domain and present modifications for future versions of the array.
ContributorsSchroeder, Edward, Ph.D (Author) / Mauskopf, Philip (Thesis advisor) / Chamberlin, Ralph (Committee member) / Lindsay, Stuart (Committee member) / Newman, Nathan (Committee member) / Easson, Damien (Committee member) / Arizona State University (Publisher)
Created2018
156861-Thumbnail Image.png
Description
In this project, current-voltage (I-V) and Deep Level Transient Spectroscopy (DLTS) measurements are used to (a) characterize the electrical properties of Nb/p-type Si Schottky barriers, (b) identify the concentration and physical character of the electrically active defects present in the depletion region, and (c) use thermal processing to reduce the

In this project, current-voltage (I-V) and Deep Level Transient Spectroscopy (DLTS) measurements are used to (a) characterize the electrical properties of Nb/p-type Si Schottky barriers, (b) identify the concentration and physical character of the electrically active defects present in the depletion region, and (c) use thermal processing to reduce the concentration or eliminate the defects. Barrier height determinations using temperature-dependent I-V measurements indicate that the barrier height decreases from 0.50 eV to 0.48 eV for anneals above 200 C. The electrically-active defect concentration measured using DLTS (deep level transient spectroscopy) drops markedly after anneals at 250 C.

A significant increase in leakage currents is almost always observed in near-ideal devices upon annealing. In contrast, non-ideal devices dominated by leakage currents annealed at 150 C to 250 C exhibit a significant decrease in such currents.
ContributorsKrishna Murthy, Madhu (Author) / Newman, Nathan (Thesis advisor) / Goryll, Michael (Committee member) / Alford, Terry (Committee member) / Arizona State University (Publisher)
Created2018
157334-Thumbnail Image.png
Description
Lithium metal is a promising anode for the next generation lithium batteries owing to its high capacity (3860 mAh g-1) and the lowest negative reduction potential (-3.04 V). Commercial produced lithium anodes have a native rough surface which deteriorates the cycling performance of the battery. Here, an attempt has been

Lithium metal is a promising anode for the next generation lithium batteries owing to its high capacity (3860 mAh g-1) and the lowest negative reduction potential (-3.04 V). Commercial produced lithium anodes have a native rough surface which deteriorates the cycling performance of the battery. Here, an attempt has been made to deposit lithium on copper from an electrolytic cell consisting of simple electrolyte of pyridine and lithium chloride at room temperature. Water is known to react aggressively with the lithium metal, however in the electrochemical plating process, it has a significant beneficial effect in catalyzing the electrochemical reactions. The effect of trace amounts of water was investigated in air as well as in controlled atmosphere of argon, nitrogen, breathing grade dry air and ultra-zero dry air. The electrochemical products examined by Fourier transform infrared spectroscopy revealed the deposition might require the reduction of pyridine to facilitate the reduction of the lithium salt. Purity of the lithium film was determined by inductively coupled plasma mass spectrometry.
ContributorsPode, Gayatri (Author) / Newman, Nathan (Thesis advisor) / Marshall, Daniel (Committee member) / Tao, Meng (Committee member) / Arizona State University (Publisher)
Created2019
136862-Thumbnail Image.png
DescriptionThere is a growing market for lightweight firearm barrels. Currently this market is dominated by Aluminum and Carbon fiber barrels, however, Gunwright, LLC proposes an innovative new way to manufacture Titanium firearm barrels. This report offers insight into potential customers and existing competitors.
ContributorsKeberle, Katelyn Frances (Author) / Adams, Jim (Thesis director) / Newman, Nathan (Committee member) / Barrett, The Honors College (Contributor) / Materials Science and Engineering Program (Contributor)
Created2014-05
155178-Thumbnail Image.png
Description
The coexistence of superconductivity and ferromagnetic orders has been the subject of study for many years. It well known that these materials possess two competing order parameters; however the two order parameters can coexist under special circumstances inducing interesting physical phenomena. In recent years the demand of ultra-low-power, high density

The coexistence of superconductivity and ferromagnetic orders has been the subject of study for many years. It well known that these materials possess two competing order parameters; however the two order parameters can coexist under special circumstances inducing interesting physical phenomena. In recent years the demand of ultra-low-power, high density cryogenic memories has brought considerable interest to integrate superconducting and magnetic thin films in one structure to produce novel memory elements. The operation of the device depends on the unusual electronic properties associated with the Superconductor (S) /Ferromagnetic (F) proximity effect.

Niobium (Nb) based Josephson junction devices were fabricated with barriers containing two ferromagnetic layers separated by a normal metal space layer. In device operation, electrons in the superconductor are injected into the ferromagnets, causing the superconductor wavefunction to shift its phase and decay in amplitude. Such devices have two different states that depend on the relative magnetization of their ferromagnetic barrier layers, parallel or antiparallel. In these different states, the junctions have different phase shifts and critical currents. Superconducting circuits containing these devices can be designed to operate as memory cells using either one of these outputs.

To quantify the shift in phase and amplitude decay of the wavefunction through a common ferromagnet, permalloy, a series of Nb/permalloy/Nb Josephson junctions with varying ferromagnetic layer thicknesses were fabricated. Data have shown that the optimal thickness of a fixed layer composed of permalloy is 2.4 nm, as it shifts the wavefunction phase to π/2, its “pivot point.” If set to precisely this value, the free layer in SFNF'S junctions will switch the junction into either the 0 or π state depending on its magnetic orientation. To minimize the free-layer switching energy dilute Cu-permalloy alloy [Cu0.7(Ni80Fe20)0.3] with a low magnetic saturation (Ms of ~80 emu/cm3) was used as the free layer. These devices exhibit switching energies at small magnetic fields, demonstrating their potential use for low power non-volatile memory for superconductor circuits.

Lastly, to study the proximity effect using other potentially-useful ferromagnetic layers, measurements were performed on Nb/F bilayers and Nb/F/AlOx/Al tunnel junctions with ferromagnets Ni8Fe19, Ni65Fe15Co20, and Pd1-xNix. The dependence of the critical temperature of the bilayers and density of states that propagated through the ferromagnetic layer were studied as a function of thickness. From this study, crucial magnetic and electrical parameters like magnetic coherence lengths (ξF), exchange energy (Eex), and the rate of shift in the wavefunction’s phase and amplitude as a function of thickness were determined.
ContributorsAbd El Qader, Makram (Author) / Newman, Nathan (Thesis advisor) / Rowell, John (Committee member) / Rizzo, Nick (Committee member) / Yu, Hongbin (Committee member) / Arizona State University (Publisher)
Created2016
148222-Thumbnail Image.png
Description

When you are sitting at the terminal waiting for your flight or taking the bus to get to work, have you ever thought about who used your seat last? More importantly, have you ever thought about the last time that seat was cleaned? Sadly, it is uncertain to see if

When you are sitting at the terminal waiting for your flight or taking the bus to get to work, have you ever thought about who used your seat last? More importantly, have you ever thought about the last time that seat was cleaned? Sadly, it is uncertain to see if it was properly sanitized in the last hour, yesterday, in the last week, or even last month. Especially during these tough times, everyone wants to be assured that they are always in a safe and healthy environment. Through the Founders Lab, our team is collaborating with an engineering capstone team to bring automated seat cleaning technology into the market. This product is a custom-designed seat cover that is tear-resistant and provides a sanitary surface for anyone to sit on. When someone leaves the seat, a pressure sensor is triggered, and the cover is replaced with a secondary cover that was stored in a UV radiated container. The waterproof fabric and internal filters prevent spills and food crumbs from remaining when the user changes. The reason for bringing this product into the market is due to the unsanitary conditions in many high traffic areas. This technology can be implemented in public transportation, restaurants, sports stadiums, and much more. It will instantly improve the efficiency of sanitation for many businesses and keep a promise to its users that they will never bring something they sat on back home. #Safeseating

ContributorsJawahar, Nandita (Co-author) / Yang, Tiger (Co-author) / Nimmagadda, Viraj (Co-author) / Byrne, Jared (Thesis director) / Sebold, Brent (Committee member) / Department of Finance (Contributor) / Department of Information Systems (Contributor) / School of Community Resources and Development (Contributor) / Department of Supply Chain Management (Contributor) / Barrett, The Honors College (Contributor)
Created2021-05
Description

Our project is to create a simplified, portable, modular electrocardiogram known as ECG/EKG. Most medical facilities, including hospitals, clinics, and skilled nursing facilities, still rely on traditional 12-lead EKG equipment consisting of a large cart with long 10 wires. These wires can be a pain to constantly detangle and rearrange

Our project is to create a simplified, portable, modular electrocardiogram known as ECG/EKG. Most medical facilities, including hospitals, clinics, and skilled nursing facilities, still rely on traditional 12-lead EKG equipment consisting of a large cart with long 10 wires. These wires can be a pain to constantly detangle and rearrange to determine a person’s heart conditions. This creates issues in fast paced scenarios such as when a patient is experiencing a heart attack and needs an EKG stat. Additionally, the current technology can be somewhat unreliable at determining heart conditions, causing providers to request multiple EKG’s for patients. With our improved versatile EKG, we can help solve these issues and implement additional outpatient use with its portable features. This can be done by remotely monitoring heart conditions during activities such as exercise, sleep, or stressful events, without worrying about wire disturbance.

ContributorsLam, Jadon (Author) / Mullins, Hunter (Co-author) / Huang, Hai (Co-author) / Taut, Sarah (Co-author) / Lee, Youngju (Co-author) / Goode, Zachary (Co-author) / Byrne, Jared (Thesis director) / Swader, Melissa (Committee member) / McElfish, Alex (Committee member) / Barrett, The Honors College (Contributor) / Department of Information Systems (Contributor) / Human Systems Engineering (Contributor)
Created2023-05
Description

Our project is to create a simplified, portable, modular electrocardiogram known as ECG/EKG. Most medical facilities, including hospitals, clinics, and skilled nursing facilities, still rely on traditional 12-lead EKG equipment consisting of a large cart with long 10 wires. These wires can be a pain to constantly detangle and rearrange

Our project is to create a simplified, portable, modular electrocardiogram known as ECG/EKG. Most medical facilities, including hospitals, clinics, and skilled nursing facilities, still rely on traditional 12-lead EKG equipment consisting of a large cart with long 10 wires. These wires can be a pain to constantly detangle and rearrange to determine a person’s heart conditions. This creates issues in fast paced scenarios such as when a patient is experiencing a heart attack and needs an EKG stat. Additionally, the current technology can be somewhat unreliable at determining heart conditions, causing providers to request multiple EKG’s for patients. With our improved versatile EKG, we can help solve these issues and implement additional outpatient use with its portable features. This can be done by remotely monitoring heart conditions during activities such as exercise, sleep, or stressful events, without worrying about wire disturbance.

ContributorsMullins, Hunter (Author) / Lam, Jadon (Co-author) / Goode, Zachary (Co-author) / Taut, Sarah (Co-author) / Lee, Youngju (Co-author) / Huang, Hai (Co-author) / Byrne, Jared (Thesis director) / Swader, Melissa (Committee member) / McElfish, Alex (Committee member) / Barrett, The Honors College (Contributor) / Engineering Programs (Contributor)
Created2023-05
Description

Our project is to create a simplified, portable, modular electrocardiogram known as ECG/EKG. Most medical facilities, including hospitals, clinics, and skilled nursing facilities, still rely on traditional 12-lead EKG equipment consisting of a large cart with long 10 wires. These wires can be a pain to constantly detangle and rearrange

Our project is to create a simplified, portable, modular electrocardiogram known as ECG/EKG. Most medical facilities, including hospitals, clinics, and skilled nursing facilities, still rely on traditional 12-lead EKG equipment consisting of a large cart with long 10 wires. These wires can be a pain to constantly detangle and rearrange to determine a person’s heart conditions. This creates issues in fast paced scenarios such as when a patient is experiencing a heart attack and needs an EKG stat. Additionally, the current technology can be somewhat unreliable at determining heart conditions, causing providers to request multiple EKG’s for patients. With our improved versatile EKG, we can help solve these issues and implement additional outpatient use with its portable features. This can be done by remotely monitoring heart conditions during activities such as exercise, sleep, or stressful events, without worrying about wire disturbance.

ContributorsLee, Youngju (Author) / Taut, Sarah (Co-author) / Goode, Zachary (Co-author) / Lam, Jadon (Co-author) / Huang, Hai (Co-author) / Mullins, Hunter (Co-author) / Byrne, Jared (Thesis director) / Swader, Melissa (Committee member) / McElfish, Alex (Committee member) / Barrett, The Honors College (Contributor) / Department of Management and Entrepreneurship (Contributor) / Dean, W.P. Carey School of Business (Contributor)
Created2023-05
Description

Our project is to create a simplified, portable, modular electrocardiogram known as ECG/EKG. Most medical facilities, including hospitals, clinics, and skilled nursing facilities, still rely on traditional 12-lead EKG equipment consisting of a large cart with long 10 wires. These wires can be a pain to constantly detangle and rearrange

Our project is to create a simplified, portable, modular electrocardiogram known as ECG/EKG. Most medical facilities, including hospitals, clinics, and skilled nursing facilities, still rely on traditional 12-lead EKG equipment consisting of a large cart with long 10 wires. These wires can be a pain to constantly detangle and rearrange to determine a person’s heart conditions. This creates issues in fast paced scenarios such as when a patient is experiencing a heart attack and needs an EKG stat. Additionally, the current technology can be somewhat unreliable at determining heart conditions, causing providers to request multiple EKG’s for patients. With our improved versatile EKG, we can help solve these issues and implement additional outpatient use with its portable features. This can be done by remotely monitoring heart conditions during activities such as exercise, sleep, or stressful events, without worrying about wire disturbance.

ContributorsGoode, Zachary (Author) / Huang, Hai (Co-author) / Lam, Jadon (Co-author) / Lee, Youngju (Co-author) / Taut, Sarah (Co-author) / Mullins, Hunter (Co-author) / Byrne, Jared (Thesis director) / Swader, Melissa (Committee member) / Barrett, The Honors College (Contributor) / Engineering Programs (Contributor) / School of Manufacturing Systems and Networks (Contributor)
Created2023-05