Matching Items (3)
Filtering by

Clear all filters

137496-Thumbnail Image.png
Description
A hybrid PV/T module was built, consisting of a thermal liquid heating system and a photovoltaic module system that combine in a hybrid format. This report will discuss the work on the project from Fall 2012 to Spring 2013 and the extended section on the economics for the Honors Thesis.

A hybrid PV/T module was built, consisting of a thermal liquid heating system and a photovoltaic module system that combine in a hybrid format. This report will discuss the work on the project from Fall 2012 to Spring 2013 and the extended section on the economics for the Honors Thesis. Three stages of experiments were completed. Stage 1 showed our project was functional as we were able to verify our panel produced electricity and increased the temperature of water flowing in the system by 0.65°C. Stage 2 testing included “gluing” the flow system to the back of the panel resulting in an average increase of 4.76°C in the temperature of the water in the system. Stage 3 testing included adding insulating foam to the module which resulted in increasing the average temperature of the water in our flow system by 6.95°C. The economic calculations show the expected energy cost savings for Arizona residents.
ContributorsHaines, Brent Robert (Author) / Roedel, Ronald (Thesis director) / Aberle, James (Committee member) / Rauch, Dawson (Committee member) / Barrett, The Honors College (Contributor) / Electrical Engineering Program (Contributor)
Created2013-05
161744-Thumbnail Image.png
Description
This thesis presents three novel studies. The first two works focus on galvanically isolated chip-to-chip communication, and the third research studies class-E pulse-width modulated power amplifiers. First, a common-mode resilient CMOS (complementary metal-oxide-semiconductor) galvanically isolated Radio Frequency (RF) chip-to-chip communication system is presented utilizing laterally resonant coupled circuits to increases

This thesis presents three novel studies. The first two works focus on galvanically isolated chip-to-chip communication, and the third research studies class-E pulse-width modulated power amplifiers. First, a common-mode resilient CMOS (complementary metal-oxide-semiconductor) galvanically isolated Radio Frequency (RF) chip-to-chip communication system is presented utilizing laterally resonant coupled circuits to increases maximum common-mode transient immunity and the isolation capability of galvanic isolators in a low-cost standard CMOS solution beyond the limits provided from the vertical coupling. The design provides the highest reported CMTI (common-mode transient immunity) of more than 600 kV/µs, 5 kVpk isolation, and a chip area of 0.95 mm2. In the second work, a bi-directional ultra-wideband transformer-coupled galvanic isolator is reported for the first time. The proposed design merges the functionality of two isolated channels into one magnetically coupled communication, enabling up to 50% form-factor and assembly cost reduction while achieving a simultaneously robust and state-of-art performance. This work achieves simultaneous robust, wideband, and energy-efficient performance of 300 Mb/s data rate, isolation of 7.8 kVrms, and power consumption and propagation delay of 200 pJ/b and 5 ns, respectively, in only 0.8 mm2 area. The third works studies class-E pulse-width modulated (PWM) Power amplifiers (PAs). For the first time, it presents a design technique to significantly extend the Power back-off (PBO) dynamic range of PWM PAs over the prior art. A proof-of-concept watt-level class-E PA is designed using a GaN HEMT and exhibits more than 6dB dynamic range for a 50 to 30 percent duty cycle variation. Moreover, in this work, the effects of non-idealities on performance and design of class-E power amplifiers for variable supply on and pulse-width operations are characterized and studied, including the effect of non-linear parasitic capacitances and its exploitation for enhancement of average efficiency and self-heating effects in class-E SMPAs using a new over dry-ice measurement technique was presented for this first time. The non-ideality study allows for capturing a full view of the design requirement and considerations of class-E power amplifiers and provides a window to the phenomena that lead to a mismatch between the ideal and actual performance of class-E power amplifiers and their root causes.
ContributorsJavidahmadabadi, Mahdi (Author) / Kitchen, Jennifer N (Thesis advisor) / Aberle, James (Committee member) / Bakkaloglu, Bertan (Committee member) / Burton, Richard (Committee member) / Arizona State University (Publisher)
Created2021
190806-Thumbnail Image.png
Description
In 1946 Felix Bloch first demonstrated the phenomenon of nuclear magnetic resonance using continuous-wave signal generation and acquisition. Shortly after in 1966, Richard R. Ernst demonstrated the breakthrough that nuclear magnetic resonance needed to develop into magnetic resonance imaging: the application of Fourier transforms for sensitive pulsed imaging. Upon this

In 1946 Felix Bloch first demonstrated the phenomenon of nuclear magnetic resonance using continuous-wave signal generation and acquisition. Shortly after in 1966, Richard R. Ernst demonstrated the breakthrough that nuclear magnetic resonance needed to develop into magnetic resonance imaging: the application of Fourier transforms for sensitive pulsed imaging. Upon this discovery, the world of research began to develop high power radio amplifiers and fast radio switches for pulsed experimentation. Consequently, continuous-wave imaging placed on the backburner.Although high power pulses are dominant in clinical imaging, there are unique advantages to low power, continuous-wave pulse sequences that transmit and receive signals simultaneously. Primarily, tissues or materials with short T2 time constants can be imaged and the peak radio power required is drastically reduced. The fundamental problem with this lies in its nature; the transmitter leaks a strong leakage signal into the receiver, thus saturating the receiver and the intended nuclear magnetic resonance signal is lost noise. Demonstrated in this dissertation is a multichannel standalone simultaneous transmit and receive (STAR) system with remote user-control that enables continuous- wave full-duplex imaging. STAR calibrates cancellation signals through vector modulators that match the leakage signal of each receiver in amplitude but opposite in phase, therefore destructively interfering the leakage signals. STAR does not require specific imaging coils or console inputs for calibration. It was designed to be general- purpose, therefore integrating into any imaging system. To begin, the user uses an Android tablet to tune STAR to match the Larmor frequency in the bore. Then, the user tells STAR to begin calibration. After self-calibrating, the user may fine-tune the calibration state of the system before enabling a low-power mode for system electronics and imaging may commence. STAR was demonstrated to isolate two receiver coils upwards of 70 dB from the transmit coil and is readily upgradable to enable the use of four receive coils. Some primary concerns of STAR are the removal of transceivers for multichannel operation, digital circuit noise, external noise, calibration speed, upgradability, and the isolation introduced; all of which are addressed in the proceeding thesis.
ContributorsColwell, Zachary Allen (Author) / Sohn, Sung-Min (Thesis advisor) / Trichopoulos, Georgios (Thesis advisor) / Aberle, James (Committee member) / Sadleir, Rosalind (Committee member) / Arizona State University (Publisher)
Created2023