Matching Items (4)
Filtering by

Clear all filters

137496-Thumbnail Image.png
Description
A hybrid PV/T module was built, consisting of a thermal liquid heating system and a photovoltaic module system that combine in a hybrid format. This report will discuss the work on the project from Fall 2012 to Spring 2013 and the extended section on the economics for the Honors Thesis.

A hybrid PV/T module was built, consisting of a thermal liquid heating system and a photovoltaic module system that combine in a hybrid format. This report will discuss the work on the project from Fall 2012 to Spring 2013 and the extended section on the economics for the Honors Thesis. Three stages of experiments were completed. Stage 1 showed our project was functional as we were able to verify our panel produced electricity and increased the temperature of water flowing in the system by 0.65°C. Stage 2 testing included “gluing” the flow system to the back of the panel resulting in an average increase of 4.76°C in the temperature of the water in the system. Stage 3 testing included adding insulating foam to the module which resulted in increasing the average temperature of the water in our flow system by 6.95°C. The economic calculations show the expected energy cost savings for Arizona residents.
ContributorsHaines, Brent Robert (Author) / Roedel, Ronald (Thesis director) / Aberle, James (Committee member) / Rauch, Dawson (Committee member) / Barrett, The Honors College (Contributor) / Electrical Engineering Program (Contributor)
Created2013-05
168415-Thumbnail Image.png
Description
Satellite communications employs circular polarization (CP) to circumvent thewell-known phenomenon known as Faraday Rotation, where the ionosphere rotates the horizontal and vertical polarization components resulting in signal degradation especially at lower frequencies, i.e., VHF and L-band, and in tropical regions of the earth. Satellite circularly polarized antenna feed technology commonly employs bulkyand

Satellite communications employs circular polarization (CP) to circumvent thewell-known phenomenon known as Faraday Rotation, where the ionosphere rotates the horizontal and vertical polarization components resulting in signal degradation especially at lower frequencies, i.e., VHF and L-band, and in tropical regions of the earth. Satellite circularly polarized antenna feed technology commonly employs bulkyand lossy 90-degree hybrid combiners to convert linear polarization to circular polarization, which results in a higher noise figure for receive applications and a less repeatable and more difficult design to tune and manufacture. This thesis aims at designing, modeling and simulating a prototype S/X dual bandCP feed/polarizer utilizing a technique known as the “Spread-Squeeze” polarizer, which offers the advantages of compact size, ease of manufacture, and lower loss and noise figure, relative to the current technology that often employs an external 3-dB hybrid combiner. Ansys High Frequency Structure Simulator (HFSS), a commercial electromagnetic modeling and simulation tool, is used for the simulations. Further, this thesis aims to characterize the performance of the dual feed hornwith respect to aperture efficiency, that is, the degree to which the feed horn illuminates the parabolic reflector.
ContributorsCowan, Brad (Author) / Aberle, James (Thesis advisor) / Pan, George (Committee member) / Trichopoulos, Georgios (Committee member) / Arizona State University (Publisher)
Created2021
190806-Thumbnail Image.png
Description
In 1946 Felix Bloch first demonstrated the phenomenon of nuclear magnetic resonance using continuous-wave signal generation and acquisition. Shortly after in 1966, Richard R. Ernst demonstrated the breakthrough that nuclear magnetic resonance needed to develop into magnetic resonance imaging: the application of Fourier transforms for sensitive pulsed imaging. Upon this

In 1946 Felix Bloch first demonstrated the phenomenon of nuclear magnetic resonance using continuous-wave signal generation and acquisition. Shortly after in 1966, Richard R. Ernst demonstrated the breakthrough that nuclear magnetic resonance needed to develop into magnetic resonance imaging: the application of Fourier transforms for sensitive pulsed imaging. Upon this discovery, the world of research began to develop high power radio amplifiers and fast radio switches for pulsed experimentation. Consequently, continuous-wave imaging placed on the backburner.Although high power pulses are dominant in clinical imaging, there are unique advantages to low power, continuous-wave pulse sequences that transmit and receive signals simultaneously. Primarily, tissues or materials with short T2 time constants can be imaged and the peak radio power required is drastically reduced. The fundamental problem with this lies in its nature; the transmitter leaks a strong leakage signal into the receiver, thus saturating the receiver and the intended nuclear magnetic resonance signal is lost noise. Demonstrated in this dissertation is a multichannel standalone simultaneous transmit and receive (STAR) system with remote user-control that enables continuous- wave full-duplex imaging. STAR calibrates cancellation signals through vector modulators that match the leakage signal of each receiver in amplitude but opposite in phase, therefore destructively interfering the leakage signals. STAR does not require specific imaging coils or console inputs for calibration. It was designed to be general- purpose, therefore integrating into any imaging system. To begin, the user uses an Android tablet to tune STAR to match the Larmor frequency in the bore. Then, the user tells STAR to begin calibration. After self-calibrating, the user may fine-tune the calibration state of the system before enabling a low-power mode for system electronics and imaging may commence. STAR was demonstrated to isolate two receiver coils upwards of 70 dB from the transmit coil and is readily upgradable to enable the use of four receive coils. Some primary concerns of STAR are the removal of transceivers for multichannel operation, digital circuit noise, external noise, calibration speed, upgradability, and the isolation introduced; all of which are addressed in the proceeding thesis.
ContributorsColwell, Zachary Allen (Author) / Sohn, Sung-Min (Thesis advisor) / Trichopoulos, Georgios (Thesis advisor) / Aberle, James (Committee member) / Sadleir, Rosalind (Committee member) / Arizona State University (Publisher)
Created2023
Description
This research explores the potential use of microwave energy to detect various substances in water, with a focus on water quality assessment and pathogen detection applications. There are many non-thermal effects of microwaves on microorganisms and their resonant frequencies could be used to identify and possibly destroy harmful pathogens, such

This research explores the potential use of microwave energy to detect various substances in water, with a focus on water quality assessment and pathogen detection applications. There are many non-thermal effects of microwaves on microorganisms and their resonant frequencies could be used to identify and possibly destroy harmful pathogens, such as bacteria and viruses, without heating the water. A wide range of materials, including living organisms like Daphnia and Moina, plants, sand, plastic, and salt, were subjected to microwave measurements to assess their influence on the transmission (S21) measurements. The measurements of the living organisms did not display distinctive resonant frequencies and variations in water volume may be the source of the small measurement differences. Conversely, sand and plastic pellets affected the measurements differently, with their arrangement within the test tube emerging as a significant factor. This study also explores the impact of salinity on measurements, revealing a clear pattern that can be modeled as a series RLC resonator. Although unique resonant frequencies for the tested organisms were not identified, the presented system demonstrates the potential for detecting contaminants based on variations in measurements. Future research may extend this work to include a broader array of organisms and enhance measurement precision.
ContributorsChild, Carson (Author) / Aberle, James (Thesis director) / Blain Christen, Jennifer (Committee member) / Barrett, The Honors College (Contributor) / Electrical Engineering Program (Contributor)
Created2023-12