Matching Items (11)
Filtering by

Clear all filters

149969-Thumbnail Image.png
Description
In the search for chemical biosensors designed for patient-based physiological applications, non-invasive diagnostic approaches continue to have value. The work described in this thesis builds upon previous breath analysis studies. In particular, it seeks to assess the adsorptive mechanisms active in both acetone and ethanol biosensors designed for

In the search for chemical biosensors designed for patient-based physiological applications, non-invasive diagnostic approaches continue to have value. The work described in this thesis builds upon previous breath analysis studies. In particular, it seeks to assess the adsorptive mechanisms active in both acetone and ethanol biosensors designed for breath analysis. The thermoelectric biosensors under investigation were constructed using a thermopile for transduction and four different materials for biorecognition. The analytes, acetone and ethanol, were evaluated under dry-air and humidified-air conditions. The biosensor response to acetone concentration was found to be both repeatable and linear, while the sensor response to ethanol presence was also found to be repeatable. The different biorecognition materials produced discernible thermoelectric responses that were characteristic for each analyte. The sensor output data is presented in this report. Additionally, the results were evaluated against a mathematical model for further analysis. Ultimately, a thermoelectric biosensor based upon adsorption chemistry was developed and characterized. Additional work is needed to characterize the physicochemical action mechanism.
ContributorsWilson, Kimberly (Author) / Guilbeau, Eric (Thesis advisor) / Pizziconi, Vincent (Thesis advisor) / LaBelle, Jeffrey (Committee member) / Arizona State University (Publisher)
Created2011
137098-Thumbnail Image.png
Description
This paper summarizes the [1] ideas behind, [2] needs, [3] development, and [4] testing of 3D-printed sensor-stents known as Stentzors. This sensor was successfully developed entirely from scratch, tested, and was found to have an output of 3.2*10-6 volts per RMS pressure in pascals. This paper also recommends further work

This paper summarizes the [1] ideas behind, [2] needs, [3] development, and [4] testing of 3D-printed sensor-stents known as Stentzors. This sensor was successfully developed entirely from scratch, tested, and was found to have an output of 3.2*10-6 volts per RMS pressure in pascals. This paper also recommends further work to render the Stentzor deployable in live subjects, including [1] further design optimization, [2] electrical isolation, [3] wireless data transmission, and [4] testing for aneurysm prevention.
ContributorsMeidinger, Aaron Michael (Author) / LaBelle, Jeffrey (Thesis director) / Frakes, David (Committee member) / Barrett, The Honors College (Contributor) / Mechanical and Aerospace Engineering Program (Contributor)
Created2014-05
137067-Thumbnail Image.png
Description
Growing concern over health risks associated with environmental contaminants has prompted an increase in the search for effective detection methods. The available options provide acceptable sensitivity and specificity, but with high purchase and maintenance costs. Herein, a low-cost, portable environmental contaminant sensor was developed using electrochemical techniques and an efficient

Growing concern over health risks associated with environmental contaminants has prompted an increase in the search for effective detection methods. The available options provide acceptable sensitivity and specificity, but with high purchase and maintenance costs. Herein, a low-cost, portable environmental contaminant sensor was developed using electrochemical techniques and an efficient hydrogel capture mechanism. The sensor operates with high sensitivity and maintains specificity without the added requirement of extensive electrode modification. Rather, specificity is obtained by choosing specific potential regions in which individual contaminants show reduction or oxidation activity. A calibration curve was generated showing the utility of the sensor in detecting gas compounds reliably in reference to a current state of the art sensor. Reusability of the sensor was also demonstrated with a cyclic exposure test in which response reversibility was observed. As such, the investigated sensor shows great promise as a replacement technology in the current environmental contaminant detector industry.
ContributorsMarch, Michael Stephen (Author) / LaBelle, Jeffrey (Thesis director) / Caplan, Michael (Committee member) / Barrett, The Honors College (Contributor) / School of Mathematical and Statistical Sciences (Contributor) / Harrington Bioengineering Program (Contributor)
Created2014-05
137263-Thumbnail Image.png
Description
Diabetes mellitus is a disease characterized by many chronic and acute conditions. With the prevalence and cost quickly increasing, we seek to improve on the current standard of care and create a rapid, label free sensor for glycated albumin (GA) index using electrochemical impedance spectroscopy (EIS). The antibody, anti-HA, was

Diabetes mellitus is a disease characterized by many chronic and acute conditions. With the prevalence and cost quickly increasing, we seek to improve on the current standard of care and create a rapid, label free sensor for glycated albumin (GA) index using electrochemical impedance spectroscopy (EIS). The antibody, anti-HA, was fixed to gold electrodes and a sine wave of sweeping frequencies was induced with a range of HA, GA, and GA with HA concentrations. Each frequency in the impedance sweep was analyzed for highest response and R-squared value. The frequency with both factors optimized is specific for both the antibody-antigen binding interactions with HA and GA and was determined to be 1476 Hz and 1.18 Hz respectively in purified solutions. The correlation slope between the impedance response and concentration for albumin (0 \u2014 5400 mg/dL of albumin) was determined to be 72.28 ohm/ln(mg/dL) with an R-square value of 0.89 with a 2.27 lower limit of detection. The correlation slope between the impedance response and concentration for glycated albumin (0 \u2014 108 mg/dL) was determined to be -876.96 ohm/ln(mg/dL) with an R-squared value of 0.70 with a 0.92 mg/dL lower limit of detection (LLD). The above data confirms that EIS offers a new method of GA detection by providing unique correlation with albumin as well as glycated albumin. The unique frequency response of GA and HA allows for modulation of alternating current signals so that several other markers important in the management of diabetes could be measured with a single sensor. Future work will be necessary to establish multimarker sensing on one electrode.
ContributorsEusebio, Francis Ang (Author) / LaBelle, Jeffrey (Thesis director) / Pizziconi, Vincent (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor)
Created2014-05
Description
The action/adventure game Grad School: HGH is the final, extended version of a BME Prototyping class project in which the goal was to produce a zombie-themed game that teaches biomedical engineering concepts. The gameplay provides fast paced, exciting, and mildly addicting rooms that the player must battle and survive through,

The action/adventure game Grad School: HGH is the final, extended version of a BME Prototyping class project in which the goal was to produce a zombie-themed game that teaches biomedical engineering concepts. The gameplay provides fast paced, exciting, and mildly addicting rooms that the player must battle and survive through, followed by an engineering puzzle that must be solved in order to advance to the next room. The objective of this project was to introduce the core concepts of BME to prospective students, rather than attempt to teach an entire BME curriculum. Based on user testing at various phases in the project, we concluded that the gameplay was engaging enough to keep most users' interest through the educational puzzles, and the potential for expanding this project to reach an even greater audience is vast.
ContributorsNitescu, George (Co-author) / Medawar, Alexandre (Co-author) / Spano, Mark (Thesis director) / LaBelle, Jeffrey (Committee member) / Guiang, Kristoffer (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor)
Created2014-05
Description
Volume depletion can lead to migraines, dizziness, and significant decreases in a subject's ability to physically perform. A major cause of volume depletion is dehydration, or loss in fluids due to an imbalance in fluid intake to fluid excretion. Because proper levels of hydration are necessary in order to maintain

Volume depletion can lead to migraines, dizziness, and significant decreases in a subject's ability to physically perform. A major cause of volume depletion is dehydration, or loss in fluids due to an imbalance in fluid intake to fluid excretion. Because proper levels of hydration are necessary in order to maintain both short and long term health, the ability to monitor hydration levels is growing in clinical demand. Although devices capable of monitoring hydration level exist, these devices are expensive, invasive, or inaccurate and do not offer a continuous mode of measurement. The ideal hydration monitor for consumer use needs to be characterized by its portability, affordability, and accuracy. Also, this device would need to be noninvasive and offer continuous hydration monitoring in order to accurately assess fluctuations in hydration data throughout a specified time period. One particular method for hydration monitoring that fits the majority of these criteria is known as bioelectric impedance analysis (BIA). Although current devices using BIA do not provide acceptable levels of accuracy, portability, or continuity in data collection, BIA could potentially be modified to fit many, if not all, desired customer specifications. The analysis presented here assesses the viability of using BIA as a new standard in hydration level measurement. The analysis uses data collected from 22 subjects using an existing device that employs BIA. A regression derived for estimating TBW based on the parameters of age, weight, height, sex, and impedance is presented. Using impedance data collected for each subject, a regression was also derived for estimating impedance based on the factors of age, weight, height, and sex. The derived regression was then used to calculate a new impedance value for each subject, and these new impedance values were used to estimate TBW. Through a paired-t test between the TBW values derived by using the direct measurements versus the calculated measurements of impedance, the two samples were found to be comparable. Considerations for BIA as a noninvasive measurement of hydration are discussed.
ContributorsTenorio, Jorge Antonio (Author) / LaBelle, Jeffrey (Thesis director) / Pizziconi, Vincent (Committee member) / Spano, Mark (Committee member) / Barrett, The Honors College (Contributor) / W. P. Carey School of Business (Contributor) / Harrington Bioengineering Program (Contributor)
Created2013-05
133053-Thumbnail Image.png
Description
A point of care glucose sensor using electrochemical impedance spectroscopy (EIS) with a glutaraldehyde-linked enzyme shows promise as an effective biosensor platform. This report details the characterization of various factors on optimal binding frequency (OBF) and sensor performance to better prepare the sensor for future experimentation. Utilizing a screen printed

A point of care glucose sensor using electrochemical impedance spectroscopy (EIS) with a glutaraldehyde-linked enzyme shows promise as an effective biosensor platform. This report details the characterization of various factors on optimal binding frequency (OBF) and sensor performance to better prepare the sensor for future experimentation. Utilizing a screen printed carbon electrode, the necessary amount of glucose oxidase was determined to be 10 mg/mL. Binding time trials ranging from 1-3 minutes demonstrated that 1.5 minutes was the optimal binding time. This timeframe produced the strongest impedance response at each glucose concentration. Using this enzyme concentration and binding time, the native OBF of the biosensor was found to be 1.18 Hz using vector analysis. Temperature testing showed little change in OBF in sensors exposed to 4 \u00B0C through 43.3 \u00B0C. Only exposure to 60 \u00B0C resulted in rapid OBF change which was likely due to glucose oxidase becoming denatured. Humidity tests showed little change in OBF and sensor performance between sensors prepared at the humidities of 7.5%, 10.625% and 16.5% humidity. Alternatively, solutions containing common interference molecules such as uric acid, acetaminophen, and ascorbic acid resulted in a highly shifted OBF and drastically reduced signal.
ContributorsMatloff, Daniel (Co-author) / Khanwalker, Mukund (Co-author) / Johns, Jared (Co-author) / LaBelle, Jeffrey (Thesis director) / Pizziconi, Vincent (Committee member) / Lin, Chi (Committee member) / Dean, W.P. Carey School of Business (Contributor) / School of Life Sciences (Contributor) / Barrett, The Honors College (Contributor)
Created2018-12
134441-Thumbnail Image.png
Description
Improved pancreatic cancer diagnostic technology has the potential to improve patient prognosis by increasing cancer screening rates and encouraging early detection of the cancer. To increase the sensitivity and specificity while decreasing the cost and time investment, the emerging detection method of electrochemical impedance spectroscopy (EIS) was tested to detect

Improved pancreatic cancer diagnostic technology has the potential to improve patient prognosis by increasing cancer screening rates and encouraging early detection of the cancer. To increase the sensitivity and specificity while decreasing the cost and time investment, the emerging detection method of electrochemical impedance spectroscopy (EIS) was tested to detect two pancreatic cancer specific biomarkers. The antibodies of carcinoembryonic antigen and quiescin sulfhydryl oxidase 1 were immobilized individually to gold disk electrodes and tested for binding to their respective antigens. An AC signal of varying potential and a wide frequency sweep was applied to the electrode system and the resulting imaginary impedance values were analyzed. Based off of the highest slope and R-squared values of the collected impedance values, the optimal binding frequencies of QSOX1 and CEA with their antibodies was determined to be 97.66 Hz and 17.44 Hz, respectively. EIS was also used to test for potential multimarker detection by coimmobilizing anti-CEA and anti-QSOX1 to the surface of gold disk electrodes. Each system's impedance response was correlated to the physiological concentration range of CEA and QSOX1 individually. The resulting impedance and concentration calibration curves had R-squared values of 0.78 and 0.79 for the calculated QSOX1 and CEA, respectively. Both markers showed similar trends between the calculated and actual calibration curves for each marker. The imaginary impedance output lacks two independent peaks for the distinct optimal binding frequencies of both biomarkers after signal subtraction and show a large shift in optimal frequencies. From analyzing the co-immobilization data for the calculated and experimentally determined calibration curves of CEA and QSOX1, both curves had different correlation values between imaginary impedance values and concentration. Add and subtracting the experimental and calculated co-immobilization, QSOX1, and CEA signals suggest an oversaturation of QSOX1 used during the experiments.
ContributorsMalla, Akshara (Co-author) / Murali, Keerthana (Co-author) / LaBelle, Jeffrey (Thesis director) / Lin, Chi-En (Committee member) / Harrington Bioengineering Program (Contributor) / Barrett, The Honors College (Contributor)
Created2017-05
Description
Each year, 30,000 patients obtain transplants. To prevent graft rejection, immunosuppressants such as tacrolimus are prescribed. Due to tacrolimus's narrow therapeutic range, a dose that is too low places patients at risk for transplant rejection, but too high of a dose leads to kidney failure. The de facto method for

Each year, 30,000 patients obtain transplants. To prevent graft rejection, immunosuppressants such as tacrolimus are prescribed. Due to tacrolimus's narrow therapeutic range, a dose that is too low places patients at risk for transplant rejection, but too high of a dose leads to kidney failure. The de facto method for monitoring of transplant patient health is bimonthly blood draws, which are cumbersome, painful, and difficult to translate into urgently needed dosage changes in a timely manner. To improve long-term transplant survival rates, we propose a finger-prick sensor that will provide patients and healthcare providers with a measurement of tacrolimus, immune health (through IL-12), and kidney damage (through cystatin C) levels 100 times more frequently than the status quo. Additionally, patient quality of life will be improved due to reduction in time and pain associated with blood draws. Optimal binding frequencies for each marker were found. However, due to limitations with EIS, the integration of the detection of the three markers into one multimarker sensing platform has not yet been realized. To this end, impedance-time tests were run on each marker along with different antibodies, and optimal times of each marker were determined to be 17s, 6s, and 2s, for tacrolimus, cystatin c, and IL-12, respectively (n=6). The integration of impedance-time analysis with traditional EIS methodologies has the potential to enable multi-marker analysis by analyzing binding kinetics on a single electrode with respect to time. Thus, our results provide unique insight into possibilities to improve and facilitate detection of multiple markers not only for the sensor for solid organ transplant patients, but for the monitoring of patients with disease that also entail the observation of multiple markers. Furthermore, the use of impedance-time testing also provides the ability for another way to optimize accuracy/precision of marker detection because it specifies a particular time, in addition to a particular optimal binding frequency, at which to measure concentration.
ContributorsDoshi, Meera Kshitij (Author) / LaBelle, Jeffrey (Thesis director) / Steidley, Eric (Committee member) / Harrington Bioengineering Program (Contributor) / Sanford School of Social and Family Dynamics (Contributor) / Barrett, The Honors College (Contributor)
Created2017-05
134280-Thumbnail Image.png
Description
As of today, there does not exist a cheap diagnostic for lactate for use in trauma centers. $671 billion are spent on trauma accidents and emergency rooms, with money focused on treatments such as YSI and ELISA, costing $1500 and $200, respectively. Gold disk electrodes were used to immobilize lactate

As of today, there does not exist a cheap diagnostic for lactate for use in trauma centers. $671 billion are spent on trauma accidents and emergency rooms, with money focused on treatments such as YSI and ELISA, costing $1500 and $200, respectively. Gold disk electrodes were used to immobilize lactate dehydrogenase and glucose oxidase, with electrochemical impedance spectroscopy (EIS) used as the method for detection. Two lactate experimental runs were completed with data detailing a linear model and positive correlation for imaginary impedance and concentration, and one glucose experimental run was completed proving that a continuous system can be completed accounting for reaction and consumption using EIS, a process previously not done before.
ContributorsEltohamy, Omar Khaled (Author) / LaBelle, Jeffrey (Thesis director) / Lin, Chi-En (Committee member) / Harrington Bioengineering Program (Contributor, Contributor) / Barrett, The Honors College (Contributor)
Created2017-05