Matching Items (4)
Filtering by

Clear all filters

152898-Thumbnail Image.png
Description
Due to diminishing availability of 3He, which is the critical component of neutron detecting proportional counters, large area flexible arrays are being considered as a potential replacement for neutron detection. A large area flexible array, utilizing semiconductors for both charged particle detection and pixel readout, ensures a large detection surface

Due to diminishing availability of 3He, which is the critical component of neutron detecting proportional counters, large area flexible arrays are being considered as a potential replacement for neutron detection. A large area flexible array, utilizing semiconductors for both charged particle detection and pixel readout, ensures a large detection surface area in a light weight rugged form. Such a neutron detector could be suitable for deployment at ports of entry. The specific approach used in this research, uses a neutron converter layer which captures incident thermal neutrons, and then emits ionizing charged particles. These ionizing particles cause electron-hole pair generation within a single pixel's integrated sensing diode. The resulting charge is then amplified via a low-noise amplifier. This document begins by discussing the current state of the art in neutron detection and the associated challenges. Then, for the purpose of resolving some of these issues, recent design and modeling efforts towards developing an improved neutron detection system are described. Also presented is a low-noise active pixel sensor (APS) design capable of being implemented in low temperature indium gallium zinc oxide (InGaZnO) or amorphous silicon (a-Si:H) thin film transistor process compatible with plastic substrates. The low gain and limited scalability of this design are improved upon by implementing a new multi-stage self-resetting APS. For each APS design, successful radiation measurements are also presented using PiN diodes for charged particle detection. Next, detection array readout methodologies are modeled and analyzed, and use of a matched filter readout circuit is described as well. Finally, this document discusses detection diode integration with the designed TFT-based APSs.
ContributorsKunnen, George (Author) / Allee, David (Thesis advisor) / Garrity, Douglas (Committee member) / Gnade, Bruce (Committee member) / Holbert, Keith E. (Committee member) / Arizona State University (Publisher)
Created2014
152987-Thumbnail Image.png
Description
This work explores how flexible electronics and display technology can be applied to develop new biomedical devices for medical, biological, and life science applications. It demonstrates how new biomedical devices can be manufactured by only modifying or personalizing the upper layers of a conventional thin film transistor (TFT) display process.

This work explores how flexible electronics and display technology can be applied to develop new biomedical devices for medical, biological, and life science applications. It demonstrates how new biomedical devices can be manufactured by only modifying or personalizing the upper layers of a conventional thin film transistor (TFT) display process. This personalization was applied first to develop and demonstrate the world's largest flexible digital x-ray detector for medical and industrial imaging, and the world's first flexible ISFET pH biosensor using TFT technology. These new, flexible, digital x-ray detectors are more durable than conventional glass substrate x-ray detectors, and also can conform to the surface of the object being imaged. The new flexible ISFET pH biosensors are >10X less expensive to manufacture than comparable CMOS-based ISFETs and provide a sensing area that is orders of magnitude larger than CMOS-based ISFETs. This allows for easier integration with area intensive chemical and biological recognition material as well as allow for a larger number of unique recognition sites for low cost multiple disease and pathogen detection.

The flexible x-ray detector technology was then extended to demonstrate the viability of a new technique to seamlessly combine multiple smaller flexible x-ray detectors into a single very large, ultimately human sized, composite x-ray detector for new medical imaging applications such as single-exposure, low-dose, full-body digital radiography. Also explored, is a new approach to increase the sensitivity of digital x-ray detectors by selectively disabling rows in the active matrix array that are not part of the imaged region. It was then shown how high-resolution, flexible, organic light-emitting diode display (OLED) technology can be used to selectively stimulate and/or silence small groups of neurons on the cortical surface or within the deep brain as a potential new tool to diagnose and treat, as well as understand, neurological diseases and conditions. This work also explored the viability of a new miniaturized high sensitivity fluorescence measurement-based lab-on-a-chip optical biosensor using OLED display and a-Si:H PiN photodiode active matrix array technology for point-of-care diagnosis of multiple disease or pathogen biomarkers in a low cost disposable configuration.
ContributorsSmith, Joseph T. (Author) / Allee, David (Thesis advisor) / Goryll, Michael (Committee member) / Kozicki, Michael (Committee member) / Blain Christen, Jennifer (Committee member) / Couture, Aaron (Committee member) / Arizona State University (Publisher)
Created2014
137494-Thumbnail Image.png
Description
This project examines the science of electric field sensing and completes experiments, gathering data to support its utility for various applications. The basic system consists of a transmitter, receiver, and lock-in amplifier. The primary goal of the study was to determine if such a system could detect a human disturbance,

This project examines the science of electric field sensing and completes experiments, gathering data to support its utility for various applications. The basic system consists of a transmitter, receiver, and lock-in amplifier. The primary goal of the study was to determine if such a system could detect a human disturbance, due to the capacitance of a human body, and such a thesis was supported. Much different results were obtained when a person disturbed the electric field transmitted by the system than when other types of objects, such as chairs and electronic devices, were placed in the field. In fact, there was a distinct difference between persons of varied sizes as well. This thesis goes through the basic design of the system and the process of experimental design for determining the capabilities of such an electric field sensing system.
ContributorsBranham, Breana Michelle (Author) / Allee, David (Thesis director) / Papandreou-Suppappola, Antonia (Committee member) / Phillips, Stephen (Committee member) / Barrett, The Honors College (Contributor) / Electrical Engineering Program (Contributor) / School of International Letters and Cultures (Contributor)
Created2013-05
187695-Thumbnail Image.png
Description
In-Band Full-Duplex (IBFD) can maximize the spectral resources and enable new types of technology, but generates self-interference (SI) that must be mitigated to enable practical applications. Analog domain SI cancellation (SIC), usually implemented as a digitally controlled adaptive filter, is one technique that is necessary to mitigate the interference below

In-Band Full-Duplex (IBFD) can maximize the spectral resources and enable new types of technology, but generates self-interference (SI) that must be mitigated to enable practical applications. Analog domain SI cancellation (SIC), usually implemented as a digitally controlled adaptive filter, is one technique that is necessary to mitigate the interference below the noise floor. To maximize the efficiency and performance of the adaptive filter this thesis studies how key design choices impact the performance so that device designers can make better tradeoff decisions. Additionally, algorithms are introduced to maximize the SIC that incorporate the hardware constraints. The provided simulations show up to 45dB SIC with 7 bits of precision at 100MHz bandwidth.
ContributorsMorgenstern, Carl Willis (Author) / Bliss, Daniel W (Thesis advisor) / Herschfelt, Andrew (Committee member) / Papandreou-Suppappola, Antonia (Committee member) / Rong, Yu (Committee member) / Allee, David (Committee member) / Arizona State University (Publisher)
Created2023