Matching Items (6)
Filtering by

Clear all filters

149969-Thumbnail Image.png
Description
In the search for chemical biosensors designed for patient-based physiological applications, non-invasive diagnostic approaches continue to have value. The work described in this thesis builds upon previous breath analysis studies. In particular, it seeks to assess the adsorptive mechanisms active in both acetone and ethanol biosensors designed for

In the search for chemical biosensors designed for patient-based physiological applications, non-invasive diagnostic approaches continue to have value. The work described in this thesis builds upon previous breath analysis studies. In particular, it seeks to assess the adsorptive mechanisms active in both acetone and ethanol biosensors designed for breath analysis. The thermoelectric biosensors under investigation were constructed using a thermopile for transduction and four different materials for biorecognition. The analytes, acetone and ethanol, were evaluated under dry-air and humidified-air conditions. The biosensor response to acetone concentration was found to be both repeatable and linear, while the sensor response to ethanol presence was also found to be repeatable. The different biorecognition materials produced discernible thermoelectric responses that were characteristic for each analyte. The sensor output data is presented in this report. Additionally, the results were evaluated against a mathematical model for further analysis. Ultimately, a thermoelectric biosensor based upon adsorption chemistry was developed and characterized. Additional work is needed to characterize the physicochemical action mechanism.
ContributorsWilson, Kimberly (Author) / Guilbeau, Eric (Thesis advisor) / Pizziconi, Vincent (Thesis advisor) / LaBelle, Jeffrey (Committee member) / Arizona State University (Publisher)
Created2011
Description
Volume depletion can lead to migraines, dizziness, and significant decreases in a subject's ability to physically perform. A major cause of volume depletion is dehydration, or loss in fluids due to an imbalance in fluid intake to fluid excretion. Because proper levels of hydration are necessary in order to maintain

Volume depletion can lead to migraines, dizziness, and significant decreases in a subject's ability to physically perform. A major cause of volume depletion is dehydration, or loss in fluids due to an imbalance in fluid intake to fluid excretion. Because proper levels of hydration are necessary in order to maintain both short and long term health, the ability to monitor hydration levels is growing in clinical demand. Although devices capable of monitoring hydration level exist, these devices are expensive, invasive, or inaccurate and do not offer a continuous mode of measurement. The ideal hydration monitor for consumer use needs to be characterized by its portability, affordability, and accuracy. Also, this device would need to be noninvasive and offer continuous hydration monitoring in order to accurately assess fluctuations in hydration data throughout a specified time period. One particular method for hydration monitoring that fits the majority of these criteria is known as bioelectric impedance analysis (BIA). Although current devices using BIA do not provide acceptable levels of accuracy, portability, or continuity in data collection, BIA could potentially be modified to fit many, if not all, desired customer specifications. The analysis presented here assesses the viability of using BIA as a new standard in hydration level measurement. The analysis uses data collected from 22 subjects using an existing device that employs BIA. A regression derived for estimating TBW based on the parameters of age, weight, height, sex, and impedance is presented. Using impedance data collected for each subject, a regression was also derived for estimating impedance based on the factors of age, weight, height, and sex. The derived regression was then used to calculate a new impedance value for each subject, and these new impedance values were used to estimate TBW. Through a paired-t test between the TBW values derived by using the direct measurements versus the calculated measurements of impedance, the two samples were found to be comparable. Considerations for BIA as a noninvasive measurement of hydration are discussed.
ContributorsTenorio, Jorge Antonio (Author) / LaBelle, Jeffrey (Thesis director) / Pizziconi, Vincent (Committee member) / Spano, Mark (Committee member) / Barrett, The Honors College (Contributor) / W. P. Carey School of Business (Contributor) / Harrington Bioengineering Program (Contributor)
Created2013-05
155565-Thumbnail Image.png
Description
The American Diabetes Association reports that diabetes costs $322 billion annually and affects 29.1 million Americans. The high out-of-pocket cost of managing diabetes can lead to noncompliance causing serious and expensive complications. There is a large market potential for a more cost-effective alternative to the current market standard of screen-printed

The American Diabetes Association reports that diabetes costs $322 billion annually and affects 29.1 million Americans. The high out-of-pocket cost of managing diabetes can lead to noncompliance causing serious and expensive complications. There is a large market potential for a more cost-effective alternative to the current market standard of screen-printed self-monitoring blood glucose (SMBG) strips. Additive manufacturing, specifically 3D printing, is a developing field that is growing in popularity and functionality. 3D printers are now being used in a variety of applications from consumer goods to medical devices. Healthcare delivery will change as the availability of 3D printers expands into patient homes, which will create alternative and more cost-effective methods of monitoring and managing diseases, such as diabetes. 3D printing technology could transform this expensive industry. A 3D printed sensor was designed to have similar dimensions and features to the SMBG strips to comply with current manufacturing standards. To make the sensor electrically active, various conductive filaments were tested and the conductive graphene filament was determined to be the best material for the sensor. Experiments were conducted to determine the optimal print settings for printing this filament onto a mylar substrate, the industry standard. The reagents used include a mixture of a ferricyanide redox mediator and flavin adenine dinucleotide dependent glucose dehydrogenase. With these materials, each sensor only costs $0.40 to print and use. Before testing the 3D printed sensor, a suitable design, voltage range, and redox probe concentration were determined. Experiments demonstrated that this novel 3D printed sensor can accurately correlate current output to glucose concentration. It was verified that the sensor can accurately detect glucose levels from 25 mg/dL to 400 mg/dL, with an R2 correlation value as high as 0.97, which was critical as it covered hypoglycemic to hyperglycemic levels. This demonstrated that a 3D-printed sensor was created that had characteristics that are suitable for clinical use. This will allow diabetics to print their own test strips at home at a much lower cost compared to SMBG strips, which will reduce noncompliance due to the high cost of testing. In the future, this technology could be applied to additional biomarkers to measure and monitor other diseases.
ContributorsAdams, Anngela (Author) / LaBelle, Jeffrey (Thesis advisor) / Pizziconi, Vincent (Committee member) / Abbas, James (Committee member) / Arizona State University (Publisher)
Created2017
168488-Thumbnail Image.png
Description
Tissues within the body enable proper function throughout an individual’s life. After severe injury or disease, many tissues do not fully heal without surgical intervention. The current surgical procedures aimed to repair tissues are not sufficient to fully restore functionality. To address these challenges, current research is seeking new tissue

Tissues within the body enable proper function throughout an individual’s life. After severe injury or disease, many tissues do not fully heal without surgical intervention. The current surgical procedures aimed to repair tissues are not sufficient to fully restore functionality. To address these challenges, current research is seeking new tissue engineering approaches to promote tissue regeneration and functional recovery. Of particular interest, biomaterial scaffolds are designed to induce tissue regeneration by mimicking the biophysical and biochemical aspects of native tissue. While many scaffolds have been designed with homogenous properties, many tissues are heterogenous in nature. Thus, fabricating scaffolds that mimic these complex tissue properties is critical for inducing proper healing after injury. Within this dissertation, scaffolds were designed and fabricated to mimic the heterogenous properties of the following tissues: (1) the vocal fold, which is a complex 3D structure with spatially controlled mechanical properties; and (2) musculoskeletal tissue interfaces, which are fibrous tissues with highly organized gradients in structure and chemistry. A tri-layered hydrogel scaffold was fabricated through layer-by-layer stacking to mimic the mechanical structure of the vocal fold. Furthermore, magnetically-assisted electrospinning and thiol-norbornene photochemistry was used to fabricate fibrous scaffolds that mimic the structural and chemical organization of musculoskeletal interfacial tissues. The work presented in this dissertation further advances the tissue engineering field by using innovative techniques to design scaffolds that recapitulate the natural complexity of native tissues.
ContributorsTindell, Raymond Kevin (Author) / Holloway, Julianne (Thesis advisor) / Green, Matthew (Committee member) / Pizziconi, Vincent (Committee member) / Stephanopoulos, Nicholas (Committee member) / Acharya, Abhinav (Committee member) / Arizona State University (Publisher)
Created2021
131768-Thumbnail Image.png
Description
The aim of the present study was to review the symptoms and current treatment options of the most common skin infections seen in outpatient settings and develop a preliminary alternative treatment solution. The specific skin infections evaluated were those caused by Staphylococcus and Streptococcus bacterial species, and are frequently treated

The aim of the present study was to review the symptoms and current treatment options of the most common skin infections seen in outpatient settings and develop a preliminary alternative treatment solution. The specific skin infections evaluated were those caused by Staphylococcus and Streptococcus bacterial species, and are frequently treated with a wide variety of systemic antibiotics or topical ointments. Systemic antibiotics have shown increased occurrence of adverse side effects as well as the development of antibiotic-resistant bacteria. Additionally, these medications are usually overprescribed, which may further exacerbate negative side effects. Another issue that is addressed is the development of infections following treatment of a new laceration or other trauma to the skin. A patient may be treated for their wound with stitches or another alternative, but there is still the possibility of developing an infection later.
This study synthesizes information found from extensive research and provides a review of the most optimal techniques for developing an alternative to systemic antibiotics. The final deliverable is a report detailing the significant findings and discussing the ways that this solution may be developed further and implemented in a clinical setting. The solution is a hydrogel bandage designed to deliver antibiotics directly to the wound site, while also offering protection and enhanced wound healing. The target population is patients suffering from skin conditions in an outpatient setting. The antibiotics of interest for this solution are clindamycin, doxycycline, and trimethoprim-sulfamethoxazole (co-trimoxazole), as they offer excellent treatment against gram-positive bacteria and methicillin-resistant Staphylococcus aureus. However, other broad-spectrum antibiotics could potentially be incorporated to protect against gram-negative bacteria. The design features a polyvinyl alcohol (PVA) hydrogel that has shown many properties that are beneficial to biomedical applications, including biocompatibility, flexibility, high drug-loading capacity, high absorption of wound exudate, increased promotion of wound healing, and more. Preliminary mathematical models of the hydrogel’s drug delivery behaviors are also included. Due to the scope and timeframe of this project, the majority of findings herein are based on research of prior literature instead of development of the novel device. Future directions would include further research and development of the mechanisms behind the device, creation of a physical prototype, experimental testing, and statistical analyses to verify device specifications and capabilities.
ContributorsTanner, Emily Christine (Author) / Pizziconi, Vincent (Thesis director) / Nguyen, Eric (Committee member) / Harrington Bioengineering Program (Contributor, Contributor) / School of Mathematical and Statistical Sciences (Contributor) / Barrett, The Honors College (Contributor)
Created2020-05
131779-Thumbnail Image.png
Description
This thesis aims to incorporate exosomes into an electrospun scaffold for tissue engineering applications. The motivation for this work is to develop an implant to regenerate tissue for patients with laryngeal defects. It was determined that it is feasible to incorporate exosomes into an electrospun scaffold. This addition of exosomes

This thesis aims to incorporate exosomes into an electrospun scaffold for tissue engineering applications. The motivation for this work is to develop an implant to regenerate tissue for patients with laryngeal defects. It was determined that it is feasible to incorporate exosomes into an electrospun scaffold. This addition of exosomes does alter the scaffold properties, by decreasing the average fiber diameter by roughly a factor of three and increasing the average modulus by roughly a factor of two. Cells were cultured on a scaffold with exosomes incorporated and were found to proliferate more than on a scaffold alone. This research lays the groundwork for further developing and optimizing an electrospun scaffold with exosomes incorporated to elicit a tissue regenerative response.
ContributorsKennedy, Maeve (Author) / Pizziconi, Vincent (Thesis director) / McPhail, Michael (Committee member) / School of International Letters and Cultures (Contributor) / Chemical Engineering Program (Contributor) / Barrett, The Honors College (Contributor)
Created2020-05