Description
A hybrid PV/T module was built, consisting of a thermal liquid heating system and a photovoltaic module system that combine in a hybrid format. This report will discuss the work on the project from Fall 2012 to Spring 2013 and the extended section on the economics for the Honors Thesis.

A hybrid PV/T module was built, consisting of a thermal liquid heating system and a photovoltaic module system that combine in a hybrid format. This report will discuss the work on the project from Fall 2012 to Spring 2013 and the extended section on the economics for the Honors Thesis. Three stages of experiments were completed. Stage 1 showed our project was functional as we were able to verify our panel produced electricity and increased the temperature of water flowing in the system by 0.65°C. Stage 2 testing included “gluing” the flow system to the back of the panel resulting in an average increase of 4.76°C in the temperature of the water in the system. Stage 3 testing included adding insulating foam to the module which resulted in increasing the average temperature of the water in our flow system by 6.95°C. The economic calculations show the expected energy cost savings for Arizona residents.
ContributorsHaines, Brent Robert (Author) / Roedel, Ronald (Thesis director) / Aberle, James (Committee member) / Rauch, Dawson (Committee member) / Barrett, The Honors College (Contributor) / Electrical Engineering Program (Contributor)
Created2013-05
132515-Thumbnail Image.png
Description
This Creative Project was carried out in coordination with the capstone project, Around the Corner Imaging with Terahertz Waves. This capstone project deals with a system designed to implement Around the Corner, or Non Line-of-Sight (NLoS) Imaging. This document discusses the creation of a GUI using MATLAB to control the

This Creative Project was carried out in coordination with the capstone project, Around the Corner Imaging with Terahertz Waves. This capstone project deals with a system designed to implement Around the Corner, or Non Line-of-Sight (NLoS) Imaging. This document discusses the creation of a GUI using MATLAB to control the Terahertz Imaging system. The GUI was developed in response to a need for synchronization, ease of operation, easy parameter modification, and data management. Along the way, many design decisions were made ranging from choosing a software platform to determining how variables should be passed. These decisions and considerations are discussed in this document. The resulting GUI has measured up to the design criteria and will be able to be used by anyone wishing to use the Terahertz Imaging System for further research in the field of Around the Corner or NLoS Imaging.
ContributorsWood, Jacob Cannon (Author) / Trichopoulos, Georgios (Thesis director) / Aberle, James (Committee member) / Electrical Engineering Program (Contributor) / School of Mathematical and Statistical Sciences (Contributor) / Barrett, The Honors College (Contributor)
Created2019-05
130973-Thumbnail Image.png
Description
The purpose of this project is to analyze the MIT OpenCourseWare coffee can radar design and modify it to be better suited for drone based synthetic aperture radar (SAR) applications while maintaining the low-cost aspect of the original design. The MIT coffee can radar can function as a ranged radar,

The purpose of this project is to analyze the MIT OpenCourseWare coffee can radar design and modify it to be better suited for drone based synthetic aperture radar (SAR) applications while maintaining the low-cost aspect of the original design. The MIT coffee can radar can function as a ranged radar, a Doppler radar, or as SAR. Through simulations and research, the suggestions for how to modify the radar resulted in swapping the coffee can monopole antennas for patch antenna arrays or helical ordinary end-fire antennas, adding an Arduino for automatic recording of output pulses, and switching from a breadboard construction to a PCB to shrink form factor and keep costs and construction time low.
ContributorsRivera, Danielle (Author) / Trichopoulos, Georgios (Thesis director) / Aberle, James (Committee member) / Department of Information Systems (Contributor) / Electrical Engineering Program (Contributor) / Barrett, The Honors College (Contributor)
Created2020-12
190806-Thumbnail Image.png
Description
In 1946 Felix Bloch first demonstrated the phenomenon of nuclear magnetic resonance using continuous-wave signal generation and acquisition. Shortly after in 1966, Richard R. Ernst demonstrated the breakthrough that nuclear magnetic resonance needed to develop into magnetic resonance imaging: the application of Fourier transforms for sensitive pulsed imaging. Upon this

In 1946 Felix Bloch first demonstrated the phenomenon of nuclear magnetic resonance using continuous-wave signal generation and acquisition. Shortly after in 1966, Richard R. Ernst demonstrated the breakthrough that nuclear magnetic resonance needed to develop into magnetic resonance imaging: the application of Fourier transforms for sensitive pulsed imaging. Upon this discovery, the world of research began to develop high power radio amplifiers and fast radio switches for pulsed experimentation. Consequently, continuous-wave imaging placed on the backburner.Although high power pulses are dominant in clinical imaging, there are unique advantages to low power, continuous-wave pulse sequences that transmit and receive signals simultaneously. Primarily, tissues or materials with short T2 time constants can be imaged and the peak radio power required is drastically reduced. The fundamental problem with this lies in its nature; the transmitter leaks a strong leakage signal into the receiver, thus saturating the receiver and the intended nuclear magnetic resonance signal is lost noise. Demonstrated in this dissertation is a multichannel standalone simultaneous transmit and receive (STAR) system with remote user-control that enables continuous- wave full-duplex imaging. STAR calibrates cancellation signals through vector modulators that match the leakage signal of each receiver in amplitude but opposite in phase, therefore destructively interfering the leakage signals. STAR does not require specific imaging coils or console inputs for calibration. It was designed to be general- purpose, therefore integrating into any imaging system. To begin, the user uses an Android tablet to tune STAR to match the Larmor frequency in the bore. Then, the user tells STAR to begin calibration. After self-calibrating, the user may fine-tune the calibration state of the system before enabling a low-power mode for system electronics and imaging may commence. STAR was demonstrated to isolate two receiver coils upwards of 70 dB from the transmit coil and is readily upgradable to enable the use of four receive coils. Some primary concerns of STAR are the removal of transceivers for multichannel operation, digital circuit noise, external noise, calibration speed, upgradability, and the isolation introduced; all of which are addressed in the proceeding thesis.
ContributorsColwell, Zachary Allen (Author) / Sohn, Sung-Min (Thesis advisor) / Trichopoulos, Georgios (Thesis advisor) / Aberle, James (Committee member) / Sadleir, Rosalind (Committee member) / Arizona State University (Publisher)
Created2023