Matching Items (12)
Filtering by

Clear all filters

133373-Thumbnail Image.png
Description
Many developing countries do not have health care systems that can afford technological biomedical devices or supplies to make such devices operational. To fill this void, nonprofit organizations, like Project C.U.R.E., recondition retired biomedical instrumentation so they can send medical supplies to help these developing countries. One of the issues

Many developing countries do not have health care systems that can afford technological biomedical devices or supplies to make such devices operational. To fill this void, nonprofit organizations, like Project C.U.R.E., recondition retired biomedical instrumentation so they can send medical supplies to help these developing countries. One of the issues with this is that sometimes the devices are unusable because components or expendable supplies are not available (Bhadelia). This issue has also been shown in the Impact Evaluations that Project C.U.R.E. receives from the clinics that explain the reasons why certain devices are no longer in use. That need underlies the idea on which this honors thesis has come into being. The purpose of this honors project was to create packing lists for biomedical instruments that Project C.U.R.E. recycles. This packing list would decrease the likelihood of important items being forgotten when sending devices. If an extra fuse, battery, light bulb, cuff or transducer is the difference between a functional or a nonfunctional medical device, such a list would be of benefit to Project C.U.R.E and these developing countries. In order to make this packing list, manuals for each device were used to determine what supplies were required, what was necessary for cleaning, and what supplies were desirable but functionally optional. This list was then added into a database that could be easily navigated and could help when packing up boxes for a shipment. The database also makes adding and editing the packing list simple and easy so that as Project C.U.R.E. gets more donated devices the packing list can grow.
ContributorsGraft, Kelsey Anne (Author) / Coursen, Jerry (Thesis director) / Walters, Danielle (Committee member) / Harrington Bioengineering Program (Contributor) / Barrett, The Honors College (Contributor)
Created2018-05
135354-Thumbnail Image.png
Description
Introduction: There are 350 to 400 pediatric heart transplants annually according to the Pediatric Heart Transplant Database (Dipchand et al. 2014). Finding appropriate donors can be challenging especially for the pediatric population. The current standard of care is a donor-to-recipient weight ratio. This ratio is not necessarily

Introduction: There are 350 to 400 pediatric heart transplants annually according to the Pediatric Heart Transplant Database (Dipchand et al. 2014). Finding appropriate donors can be challenging especially for the pediatric population. The current standard of care is a donor-to-recipient weight ratio. This ratio is not necessarily a parameter directly indicative of the size of a heart, potentially leading to ill-fitting allografts (Tang et al. 2010). In this paper, a regression model is presented - developed by correlating total cardiac volume to non-invasive imaging parameters and patient characteristics – for use in determining ideal allograft fit with respect to total cardiac volume.
Methods: A virtual, 3D library of clinically-defined normal hearts was compiled from reconstructed CT and MR scans. Non-invasive imaging parameters and patient characteristics were collected and subjected to backward elimination linear regression to define a model relating patient parameters to the total cardiac volume. This regression model was then used to retrospectively accept or reject an ‘ideal’ donor graft from the library for 3 patients that had undergone heart transplantation. Oversized and undersized grafts were also transplanted to qualitatively analyze virtual transplantation specificity.
Results: The backward elimination approach of the data for the 20 patients rejected the factors of BMI, BSA, sex and both end-systolic and end-diastolic left ventricular measurements from echocardiography. Height and weight were included in the linear regression model yielding an adjusted R-squared of 82.5%. Height and weight showed statistical significance with p-values of 0.005 and 0.02 respectively. The final equation for the linear regression model was TCV = -169.320+ 2.874h + 3.578w ± 73 (h=height, w=weight, TCV= total cardiac volume).
Discussion: With the current regression model, height and weight significantly correlate to total cardiac volume. This regression model and virtual normal heart library provide for the possibility of virtual transplant and size-matching for transplantation. The study and regression model is, however, limited due to a small sample size. Additionally, the lack of volumetric resolution from the MR datasets is a potentially limiting factor. Despite these limitations the virtual library has the potential to be a critical tool for clinical care that will continue to grow as normal hearts are added to the virtual library.
ContributorsSajadi, Susan (Co-author) / Lindquist, Jacob (Co-author) / Frakes, David (Thesis director) / Ryan, Justin (Committee member) / Harrington Bioengineering Program (Contributor) / School of International Letters and Cultures (Contributor) / Barrett, The Honors College (Contributor)
Created2016-05
135668-Thumbnail Image.png
Description
In the medical industry, there have been promising advances in the increase of new types of healthcare to the public. As of 2015, there was a 98% Premarket Approval rate, a 38% increase since 2010. In addition, there were 41 new novel drugs approved for clinical usage in 2014 where

In the medical industry, there have been promising advances in the increase of new types of healthcare to the public. As of 2015, there was a 98% Premarket Approval rate, a 38% increase since 2010. In addition, there were 41 new novel drugs approved for clinical usage in 2014 where the average in the previous years from 2005-2013 was 25. However, the research process towards creating and delivering new healthcare to the public remains remarkably inefficient. It takes on average 15 years, over $900 million by one estimate, for a less than 12% success rate of discovering a novel drug for clinical usage. Medical devices do not fare much better. Between 2005-2009, there were over 700 recalls per year. In addition, it takes at minimum 3.25 years for a 510(k) exempt premarket approval. Plus, a time lag exists where it takes 17 years for only 14% of medical discoveries to be implemented clinically. Coupled with these inefficiencies, government funding for medical research has been decreasing since 2002 (2.5% of Gross Domestic Product) and is predicted to be 1.5% of Gross Domestic Product by 2019. Translational research, the conversion of bench-side discoveries to clinical usage for a simplistic definition, has been on the rise since the 1990s. This may be driving the increased premarket approvals and new novel drug approvals. At the very least, it is worth considering as translational research is directly related towards healthcare practices. In this paper, I propose to improve the outcomes of translational research in order to better deliver advancing healthcare to the public. I suggest Best Value Performance Information Procurement System (BV PIPS) should be adapted in the selection process of translational research projects to fund. BV PIPS has been shown to increase the efficiency and success rate of delivering projects and services. There has been over 17 years of research with $6.3 billion of projects and services delivered showing that BV PIPS has a 98% customer satisfaction, 90% minimized management effort, and utilizes 50% less manpower and effort. Using University of Michigan \u2014 Coulter Foundation Program's funding process as a baseline and standard in the current selection of translational research projects to fund, I offer changes to this process based on BV PIPS that may ameliorate it. As concepts implemented in this process are congruent with literature on successful translational research, it may suggest that this new model for selecting translational research projects to fund will reduce costs, increase efficiency, and increase success. This may then lead to more Premarket Approvals, more new novel drug approvals, quicker delivery time to the market, and lower recalls.
ContributorsDel Rosario, Joseph Paul (Author) / Kashiwagi, Dean (Thesis director) / Kashiwagi, Jacob (Committee member) / Harrington Bioengineering Program (Contributor) / Barrett, The Honors College (Contributor)
Created2016-05
136814-Thumbnail Image.png
Description
The goal of this project was to explore biomimetics by creating a jellyfish flying device that uses propulsion of air to levitate while utilizing electromyography signals and infrared signals as mechanisms to control the device. Completing this project would require knowledge of biological signals, electrical circuits, computer programming, and physics

The goal of this project was to explore biomimetics by creating a jellyfish flying device that uses propulsion of air to levitate while utilizing electromyography signals and infrared signals as mechanisms to control the device. Completing this project would require knowledge of biological signals, electrical circuits, computer programming, and physics to accomplish. An EMG sensor was used to obtain processed electrical signals produced from the muscles in the forearm and was then utilized to control the actuation speed of the tentacles. An Arduino microprocessor was used to translate the EMG signals to infrared blinking sequences which would propagate commands through a constructed circuit shield to the infrared receiver on jellyfish. The receiver will then translate the received IR sequence into actions. Then the flying device must produce enough thrust to propel the body upwards. The application of biomimetics would best test my skills as an engineer as well as provide a method of applying what I have learned over the duration of my undergraduate career.
ContributorsTsui, Jessica W (Author) / Muthuswamy, Jitteran (Thesis director) / Blain Christen, Jennifer (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor)
Created2014-05
137469-Thumbnail Image.png
Description
Oxygen delivery is crucial for the development of healthy, functional tissue. Low tissue oxygenation, or hypoxia, is a characteristic that is common in many tumors. Hypoxia contributes to tumor malignancy and can reduce the success of chemotherapy and radiation treatment. There is a current need to noninvasively measure tumor oxygenation

Oxygen delivery is crucial for the development of healthy, functional tissue. Low tissue oxygenation, or hypoxia, is a characteristic that is common in many tumors. Hypoxia contributes to tumor malignancy and can reduce the success of chemotherapy and radiation treatment. There is a current need to noninvasively measure tumor oxygenation or pO2 in patients to determine a personalized treatment method. This project focuses on creating and characterizing nanoemulsions using a pO2 reporter molecule hexamethyldisiloxane (HMDSO) and its longer chain variants as well as assessing their cytotoxicity. We also explored creating multi-modal (MRI/Fluorescence) nanoemulsions.
ContributorsGrucky, Marian Louise (Author) / Kodibagkar, Vikram (Thesis director) / Rege, Kaushal (Committee member) / Stabenfeldt, Sarah (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor)
Created2013-05
134495-Thumbnail Image.png
Description
As the complexity of healthcare continues to rise, the need for change in healthcare delivery is more prominent than ever. One strategy identified by the World Health Organization (WHO) for responding to these increasing complexities is the use of interprofessional practice and education to improve patient outcomes, reduce costs, and

As the complexity of healthcare continues to rise, the need for change in healthcare delivery is more prominent than ever. One strategy identified by the World Health Organization (WHO) for responding to these increasing complexities is the use of interprofessional practice and education to improve patient outcomes, reduce costs, and enhance the patient experience of care (Triple Aim). Interprofessional collaboration among diverse disciplines is evident on the Phoenix Biomedical Campus, integrating a wide variety of institutions and multiple health profession programs; and at the Student Health Outreach for Wellness (SHOW) free clinic, -- a successful tri-university, student-led, faculty mentored, and community-based model of interprofessional learning and care -- based in downtown Phoenix. This project conducted a comparative analysis of interprofessional components of 6 different clinical models in order to provide recommendations for best practice implementation. These models were chosen based on availability of research on interprofessionalism with their clinics. As a result, three recommendations were offered to the SHOW clinic for consideration in their efforts to improve both patient and educational outcomes. Each recommendation was intentionally formulated for its capacity to increase: interprofessionalism and collaboration between multiple disciplines pertaining to healthcare, among healthcare professionals to promote positive patient and educational outcomes. These recommendations include implementing an interprofessional education (IPE) course as a core component in an academic program's curriculum, offering faculty and professional development opportunities for faculty and mentors immersed in the interprofessional clinics, and utilization of simulation centers. Further studies will be needed to evaluate the impact these specific interventions, if adopted, on patient and educational outcomes.
ContributorsMousa, Mohammad (Co-author) / Mousa, Bakir (Co-author) / Johnson, Ross (Co-author) / Harrell, Liz (Thesis director) / Saewert, Karen (Committee member) / Harrington Bioengineering Program (Contributor) / School of Life Sciences (Contributor) / Barrett, The Honors College (Contributor)
Created2017-05
133517-Thumbnail Image.png
Description
Traumatic brain injury (TBI) is a major concern in public health due to its prevalence and effect. Every year, about 1.7 million TBIs are reported [7]. According to the According to the Centers for Disease Control and Prevention (CDC), 5.5% of all emergency department visits, hospitalizations, and deaths from 2002

Traumatic brain injury (TBI) is a major concern in public health due to its prevalence and effect. Every year, about 1.7 million TBIs are reported [7]. According to the According to the Centers for Disease Control and Prevention (CDC), 5.5% of all emergency department visits, hospitalizations, and deaths from 2002 to 2006 are due to TBI [8]. The brain's natural defense, the Blood Brain Barrier (BBB), prevents the entry of most substances into the brain through the blood stream, including medicines administered to treat TBI [11]. TBI may cause the breakdown of the BBB, and may result in increased permeability, providing an opportunity for NPs to enter the brain [3,4]. Dr. Stabenfeldt's lab has previously established that intravenously injected nanoparticles (NP) will accumulate near the injury site after focal brain injury [4]. The current project focuses on confirmation of the accumulation or extravasation of NPs after brain injury using 2-photon microscopy. Specifically, the project used controlled cortical impact injury induced mice models that were intravenously injected with 40nm NPs post-injury. The MATLAB code seeks to analyze the brain images through registration, segmentation, and intensity measurement and evaluate if fluorescent NPs will accumulate in the extravascular tissue of injured mice models. The code was developed with 2D bicubic interpolation, subpixel image registration, drawn dimension segmentation and fixed dimension segmentation, and dynamic image analysis. A statistical difference was found between the extravascular tissue of injured and uninjured mouse models. This statistical difference proves that the NPs do extravasate through the permeable cranial blood vessels in injured cranial tissue.
ContributorsIrwin, Jacob Aleksandr (Author) / Stabenfeldt, Sarah (Thesis director) / Bharadwaj, Vimala (Committee member) / Harrington Bioengineering Program (Contributor) / Barrett, The Honors College (Contributor)
Created2018-05
133100-Thumbnail Image.png
Description
This thesis project discusses the transitions of the physician profession and their struggle to maintain autonomy throughout American History until approximately the 1980's. Included in the historical account of the physician profession, is the development of the American Hospital System and its origins working under the physician profession. As history

This thesis project discusses the transitions of the physician profession and their struggle to maintain autonomy throughout American History until approximately the 1980's. Included in the historical account of the physician profession, is the development of the American Hospital System and its origins working under the physician profession. As history progresses from 1760 on, what comes to light is a cyclical struggle for physicians to remain independent from the corporations, while using them to gain social and economic prestige. This work focuses on how the establishment of private practice in the United States has lead to the current system in place today, illustrating a long fight for control of the medical field that still rages on today. As physicians gained power and autonomy in the medical field during the 20th century, constant attempts of government intervention can be seen within the convoluted history of this professional field. The rise of corporate healthcare, that works in tandem with private physicians, was a critical period in forgotten American History that subsequently allowed physicians to increase their stranglehold on the medical service industry. The goal of this research was to establish a better understanding of American Medicine's history to better tackle the new problems we face today. As America transitions to a period of public health outcry, it is important to establish a somewhat linear rendition of a mostly untold history that directly impacts the lives of every citizen in this country. This work attempts to mend the broken pieces of that history to give light to how healthcare evolved into what it is today.
ContributorsParkhurst, Erik Lewis (Author) / Tyler, William (Thesis director) / Coursen, Jerry (Committee member) / Harrington Bioengineering Program (Contributor) / Barrett, The Honors College (Contributor)
Created2018-12
157900-Thumbnail Image.png
Description
Readout Integrated Circuits(ROICs) are important components of infrared(IR) imag

ing systems. Performance of ROICs affect the quality of images obtained from IR

imaging systems. Contemporary infrared imaging applications demand ROICs that

can support large dynamic range, high frame rate, high output data rate, at low

cost, size and power. Some of these applications are

Readout Integrated Circuits(ROICs) are important components of infrared(IR) imag

ing systems. Performance of ROICs affect the quality of images obtained from IR

imaging systems. Contemporary infrared imaging applications demand ROICs that

can support large dynamic range, high frame rate, high output data rate, at low

cost, size and power. Some of these applications are military surveillance, remote

sensing in space and earth science missions and medical diagnosis. This work focuses

on developing a ROIC unit cell prototype for National Aeronautics and Space Ad

ministration(NASA), Jet Propulsion Laboratory’s(JPL’s) space applications. These

space applications also demand high sensitivity, longer integration times(large well

capacity), wide operating temperature range, wide input current range and immunity

to radiation events such as Single Event Latchup(SEL).

This work proposes a digital ROIC(DROIC) unit cell prototype of 30ux30u size,

to be used mainly with NASA JPL’s High Operating Temperature Barrier Infrared

Detectors(HOT BIRDs). Current state of the art DROICs achieve a dynamic range

of 16 bits using advanced 65-90nm CMOS processes which adds a lot of cost overhead.

The DROIC pixel proposed in this work uses a low cost 180nm CMOS process and

supports a dynamic range of 20 bits operating at a low frame rate of 100 frames per

second(fps), and a dynamic range of 12 bits operating at a high frame rate of 5kfps.

The total electron well capacity of this DROIC pixel is 1.27 billion electrons, enabling

integration times as long as 10ms, to achieve better dynamic range. The DROIC unit

cell uses an in-pixel 12-bit coarse ADC and an external 8-bit DAC based fine ADC.

The proposed DROIC uses layout techniques that make it immune to radiation up to

300krad(Si) of total ionizing dose(TID) and single event latch-up(SEL). It also has a

wide input current range from 10pA to 1uA and supports detectors operating from

Short-wave infrared (SWIR) to longwave infrared (LWIR) regions.
ContributorsPraveen, Subramanya Chilukuri (Author) / Bakkaloglu, Bertan (Thesis advisor) / Kitchen, Jennifer (Committee member) / Long, Yu (Committee member) / Arizona State University (Publisher)
Created2019
132526-Thumbnail Image.png
Description
In the United States, an estimated 2 million cases of traumatic brain injury (TBI) resulting in more than 50,000 deaths occur every year. TBI induces an immediate primary injury resulting in local or diffuse cell death in the brain. Then a secondary injury occurs through neuroinflammation from immune cells in

In the United States, an estimated 2 million cases of traumatic brain injury (TBI) resulting in more than 50,000 deaths occur every year. TBI induces an immediate primary injury resulting in local or diffuse cell death in the brain. Then a secondary injury occurs through neuroinflammation from immune cells in response to primary injury. Microglia, the resident immune cell of the central nervous system, play a critical role in neuroinflammation following TBI. Microglia make up 10% of all cells in the nervous system and are the fastest moving cells in the brain, scanning the entire parenchyma every several hours. Microglia have roles in both the healthy and injured brain. In the healthy brain, microglia can produce neuroprotective factors, clear cellular debris, and organize neurorestorative processes to recover from TBI. However, microglia mediated neuroinflammation during secondary injury produces pro-inflammatory and cytotoxic mediators contributing to neuronal dysfunction, inhibition of CNS repair, and cell death. Furthermore, neuroinflammation is a prominent feature in many neurodegenerative diseases such as Alzheimer’s, and Parkinson’s disease, of which include overactive microglia function. Microglia cell morphology, activation, and response to TBI is poorly understood. Currently, imaging microglia can only be performed while the animal is stationary and under anesthesia. The Miniscope technology allows for real-time visualization of microglia in awake behaving animals. The Miniscope is a miniature fluorescent microscope that can be implanted over a craniectomy to image microglia. Currently, the goals of Miniscope imaging are to improve image quality and develop time-lapse imaging capabilities. There were five main sub-projects that focused on these goals including surgical nose cone design, surgical holder design, improved GRIN lens setup, improved magnification through achromatic lenses, and time-lapse imaging hardware development. Completing these goals would allow for the visualization of microglia function in the healthy and injured brain, elucidating important immune functions that could provide new strategies for treating brain diseases.
ContributorsNelson, Andrew Frederick (Author) / Stabenfeldt, Sarah (Thesis director) / Lifshitz, Jonathan (Committee member) / Harrington Bioengineering Program (Contributor) / Barrett, The Honors College (Contributor)
Created2019-05