147550-Thumbnail Image.png
Description

The honors thesis presented in this document describes an extension to an electrical engineering capstone project whose scope is to develop the receiver electronics for an RF interrogator. The RF interrogator functions by detecting the change in resonant frequency of (i.e, frequency of maximum backscatter from) a target resulting

The honors thesis presented in this document describes an extension to an electrical engineering capstone project whose scope is to develop the receiver electronics for an RF interrogator. The RF interrogator functions by detecting the change in resonant frequency of (i.e, frequency of maximum backscatter from) a target resulting from an environmental input. The general idea of this honors project was to design three frequency selective surfaces that would act as surrogate backscattering or reflecting targets that each contains a distinct frequency response. Using 3-D electromagnetic simulation software, three surrogate targets exhibiting bandpass frequency responses at distinct frequencies were designed and presented in this thesis.

ContributorsSisk, Ryan Derek (Author) / Aberle, James (Thesis director) / Chakraborty, Partha (Committee member) / Electrical Engineering Program (Contributor, Contributor) / Barrett, The Honors College (Contributor)
Created2021-05
165040-Thumbnail Image.png
Description
The ability of magnetic resonance imaging (MRI) to image any part of the human body without the effects of harmful radiation such as in CAT and PET scans established MRI as a clinical mainstay for a variety of different ailments and maladies. Short wavelengths accompany the high frequencies present in

The ability of magnetic resonance imaging (MRI) to image any part of the human body without the effects of harmful radiation such as in CAT and PET scans established MRI as a clinical mainstay for a variety of different ailments and maladies. Short wavelengths accompany the high frequencies present in high-field MRI, and are on the same scale as the human body at a static magnetic field strength of 3 T (128 MHz). As a result of these shorter wavelengths, standing wave effects are produced in the MR bore where the patient is located. These standing waves generate bright and dark spots in the resulting MR image, which correspond to irregular regions of high and low clarity. Coil loading is also an inevitable byproduct of subject positioning inside the bore, which decreases the signal that the region of interest (ROI) receives for the same input power. Several remedies have been proposed in the literature to remedy the standing wave effect, including the placement of high permittivity dielectric pads (HPDPs) near the ROI. Despite the success of HPDPs at smoothing out image brightness, these pads are traditionally bulky and take up a large spatial volume inside the already small MR bore. In recent years, artificial periodic structures known as metamaterials have been designed to exhibit specific electromagnetic effects when placed inside the bore. Although typically thinner than HPDPs, many metamaterials in the literature are rigid and cannot conform to the shape of the patient, and some are still too bulky for practical use in clinical settings. The well-known antenna engineering concept of fractalization, or the introduction of self-similar patterns, may be introduced to the metamaterial to display a specific resonance curve as well as increase the metamaterial’s intrinsic capacitance. Proposed in this paper is a flexible fractal-inspired metamaterial for application in 3 T MR head imaging. To demonstrate the advantages of this flexibility, two different metamaterial configurations are compared to determine which produces a higher localized signal-to-noise ratio (SNR) and average signal measured in the image: in the first configuration, the metamaterial is kept rigid underneath a human head phantom to represent metamaterials in the literature (single-sided placement); and in the second, the metamaterial is wrapped around the phantom to utilize its flexibility (double-sided placement). The double-sided metamaterial setup was found to produce an increase in normalized SNR of over 5% increase in five of six chosen ROIs when compared to no metamaterial use and showed a 10.14% increase in the total average signal compared to the single-sided configuration.
ContributorsSokol, Samantha (Author) / Sohn, Sung-Min (Thesis director) / Allee, David (Committee member) / Jones, Anne (Committee member) / Barrett, The Honors College (Contributor) / Electrical Engineering Program (Contributor)
Created2022-05
190806-Thumbnail Image.png
Description
In 1946 Felix Bloch first demonstrated the phenomenon of nuclear magnetic resonance using continuous-wave signal generation and acquisition. Shortly after in 1966, Richard R. Ernst demonstrated the breakthrough that nuclear magnetic resonance needed to develop into magnetic resonance imaging: the application of Fourier transforms for sensitive pulsed imaging. Upon this

In 1946 Felix Bloch first demonstrated the phenomenon of nuclear magnetic resonance using continuous-wave signal generation and acquisition. Shortly after in 1966, Richard R. Ernst demonstrated the breakthrough that nuclear magnetic resonance needed to develop into magnetic resonance imaging: the application of Fourier transforms for sensitive pulsed imaging. Upon this discovery, the world of research began to develop high power radio amplifiers and fast radio switches for pulsed experimentation. Consequently, continuous-wave imaging placed on the backburner.Although high power pulses are dominant in clinical imaging, there are unique advantages to low power, continuous-wave pulse sequences that transmit and receive signals simultaneously. Primarily, tissues or materials with short T2 time constants can be imaged and the peak radio power required is drastically reduced. The fundamental problem with this lies in its nature; the transmitter leaks a strong leakage signal into the receiver, thus saturating the receiver and the intended nuclear magnetic resonance signal is lost noise. Demonstrated in this dissertation is a multichannel standalone simultaneous transmit and receive (STAR) system with remote user-control that enables continuous- wave full-duplex imaging. STAR calibrates cancellation signals through vector modulators that match the leakage signal of each receiver in amplitude but opposite in phase, therefore destructively interfering the leakage signals. STAR does not require specific imaging coils or console inputs for calibration. It was designed to be general- purpose, therefore integrating into any imaging system. To begin, the user uses an Android tablet to tune STAR to match the Larmor frequency in the bore. Then, the user tells STAR to begin calibration. After self-calibrating, the user may fine-tune the calibration state of the system before enabling a low-power mode for system electronics and imaging may commence. STAR was demonstrated to isolate two receiver coils upwards of 70 dB from the transmit coil and is readily upgradable to enable the use of four receive coils. Some primary concerns of STAR are the removal of transceivers for multichannel operation, digital circuit noise, external noise, calibration speed, upgradability, and the isolation introduced; all of which are addressed in the proceeding thesis.
ContributorsColwell, Zachary Allen (Author) / Sohn, Sung-Min (Thesis advisor) / Trichopoulos, Georgios (Thesis advisor) / Aberle, James (Committee member) / Sadleir, Rosalind (Committee member) / Arizona State University (Publisher)
Created2023