Matching Items (6)
Filtering by

Clear all filters

152914-Thumbnail Image.png
Description
The objective of this research is to develop a biocompatible scaffold based on dextran and poly acrylic acid (PAA) with the potential to be used for soft tissue repair. In this thesis, physical and chemical properties of the scaffold were investigated. The scaffolds were made using electrospinning and cross-linked under

The objective of this research is to develop a biocompatible scaffold based on dextran and poly acrylic acid (PAA) with the potential to be used for soft tissue repair. In this thesis, physical and chemical properties of the scaffold were investigated. The scaffolds were made using electrospinning and cross-linked under high temperature. After heat treatment, Scanning Electron Microscope (SEM) was used to observe the structures of these scaffolds. Fourier transform infrared spectroscopy (FTIR) was used to measure the cross-linking level of scaffold samples given different times of heat treatment by detecting and comparing the newly formed ester bonds. Single-walled carbon nanotubes (SWCNT) were added to enhance the mechanical properties of dextran-PAA scaffolds. Attachment of NIH-3T3 fibroblast cells to the scaffold and the response upon implantation into rabbit vaginal tissue were also evaluated to investigate the performance of SWCNT dextran-PAA scaffold. SEM was then used to characterize morphology of fibroblast cells and rabbit tissues. The results suggest that SWCNT could enhance cell attachment, distribution and spreading performance of dextran-PAA scaffold.
ContributorsLiu, Chongji (Author) / Massia, Stephen (Thesis advisor) / Pizziconi, Vincent (Committee member) / Pauken, Christine (Committee member) / Arizona State University (Publisher)
Created2014
148477-Thumbnail Image.png
Description

The purpose of this study is to collect baseline internal and external pressure data for the three most commonly used pelvic circumferential compression devices (PCCD). Unstable pelvic fractures as a result of automobile accidents, falls, and other traumatic injuries mortality rate [3]. Early use of pelvic circumferential compression devices can

The purpose of this study is to collect baseline internal and external pressure data for the three most commonly used pelvic circumferential compression devices (PCCD). Unstable pelvic fractures as a result of automobile accidents, falls, and other traumatic injuries mortality rate [3]. Early use of pelvic circumferential compression devices can mitigate fatal outcomes [4]-[5]. Prolonged eternal pressure above 9.3kPa can result in long-term soft tissue damage and pressure ulcers [7]. This study hypothesizes that the application of the three most commonly used PCCDs would result in the same mean maximum point pressure exertion. To study this, internal and external, both analog and digital, pressure apparati were used to collect data. The results of this data collection demonstrate a discrepancy in the pressure distribution between right and left greater trochanters within each PCCD. Additionally, the results suggest there is an effect of internal packing on the pressure exertion externally at the two greater trochanters within each PCCD. Lastly, the differences in pressure exertion between each PCCD, internally and externally, were inconclusive as some compared metrics resulted in statistically significant results while others did not. The methodologies employed in this study can be improved through fixation of pressure collection instruments, utilization of digital pressure mats, and removal of confounding factors. The results of this study indicate that digitized, discrete data over a fixed time interval may be clinically useful, suggesting that a digital data collection would yield more reliable data. Additionally, internally mounted pressure sensor data will provide more precise results than the analog method employed herein, as well as provide insight towards bone reduction and displacement following the application of PCCDs. Finally, the information gathered from this study can be utilized to improve upon existing technologies to create a more innovative solution.

ContributorsMoore, Kameron James (Co-author) / Dewald, Alison (Co-author) / Pizziconi, Vincent (Thesis director) / Bogert, James (Committee member) / Harrington Bioengineering Program (Contributor) / School of International Letters and Cultures (Contributor) / Barrett, The Honors College (Contributor)
Created2021-05
148478-Thumbnail Image.png
Description

The purpose of this study is to collect baseline internal and external pressure data for the three most commonly used pelvic circumferential compression devices (PCCD). Unstable pelvic fractures as a result of automobile accidents, falls, and other traumatic injuries mortality rate [3]. Early use of pelvic circumferential compression devices can

The purpose of this study is to collect baseline internal and external pressure data for the three most commonly used pelvic circumferential compression devices (PCCD). Unstable pelvic fractures as a result of automobile accidents, falls, and other traumatic injuries mortality rate [3]. Early use of pelvic circumferential compression devices can mitigate fatal outcomes [4]-[5]. Prolonged eternal pressure above 9.3kPa can result in long-term soft tissue damage and pressure ulcers [7]. This study hypothesizes that the application of the three most commonly used PCCDs would result in the same mean maximum point pressure exertion. To study this, internal and external, both analog and digital, pressure apparati were used to collect data. The results of this data collection demonstrate a discrepancy in the pressure distribution between right and left greater trochanters within each PCCD. Additionally, the results suggest there is an effect of internal packing on the pressure exertion externally at the two greater trochanters within each PCCD. Lastly, the differences in pressure exertion between each PCCD, internally and externally, were inconclusive as some compared metrics resulted in statistically significant results while others did not. The methodologies employed in this study can be improved through fixation of pressure collection instruments, utilization of digital pressure mats, and removal of confounding factors. The results of this study indicate that digitized, discrete data over a fixed time interval may be clinically useful, suggesting that a digital data collection would yield more reliable data. Additionally, internally mounted pressure sensor data will provide more precise results than the analog method employed herein, as well as provide insight towards bone reduction and displacement following the application of PCCDs. Finally, the information gathered from this study can be utilized to improve upon existing technologies to create a more innovative solution.

Created2021-05
148243-Thumbnail Image.png
Description

Brave Bears was a Barrett creative project that operated under local non-profit organizations, Amanda Hope Rainbow Angels and Arizona Women’s Recovery Center. Amanda Hope Rainbow Angels provides support and education for children fighting cancer and their families. Arizona Women’s Recovery Center provides rehabilitation programs for women fighting substance abuse and

Brave Bears was a Barrett creative project that operated under local non-profit organizations, Amanda Hope Rainbow Angels and Arizona Women’s Recovery Center. Amanda Hope Rainbow Angels provides support and education for children fighting cancer and their families. Arizona Women’s Recovery Center provides rehabilitation programs for women fighting substance abuse and housing for the women and their children. The Brave Bears Project was focused on helping children in these situations cope with the trauma they are experiencing. The children received a teddy bear, which is a transitional object. In addition, a clay pendant with the word, “brave” pressed into it was tied around the bear’s neck with a ribbon. A poem of explanation and encouragement was also included.<br/><br/>The teddy bear provided comfort to children experiencing emotionally distressing situations as they receive treatment for their illness or as their mom undergoes rehabilitation. This can be in the form of holding the teddy bear when they feel frightened, anxious, lonely or depressed. The “brave” pendant and poem seek to encourage them and acknowledge their trauma and ability to persevere.

ContributorsRichards, Emma Joy (Author) / Lopez, Kristina (Thesis director) / Safyer, Paige (Committee member) / College of Health Solutions (Contributor) / Barrett, The Honors College (Contributor)
Created2021-05
168488-Thumbnail Image.png
Description
Tissues within the body enable proper function throughout an individual’s life. After severe injury or disease, many tissues do not fully heal without surgical intervention. The current surgical procedures aimed to repair tissues are not sufficient to fully restore functionality. To address these challenges, current research is seeking new tissue

Tissues within the body enable proper function throughout an individual’s life. After severe injury or disease, many tissues do not fully heal without surgical intervention. The current surgical procedures aimed to repair tissues are not sufficient to fully restore functionality. To address these challenges, current research is seeking new tissue engineering approaches to promote tissue regeneration and functional recovery. Of particular interest, biomaterial scaffolds are designed to induce tissue regeneration by mimicking the biophysical and biochemical aspects of native tissue. While many scaffolds have been designed with homogenous properties, many tissues are heterogenous in nature. Thus, fabricating scaffolds that mimic these complex tissue properties is critical for inducing proper healing after injury. Within this dissertation, scaffolds were designed and fabricated to mimic the heterogenous properties of the following tissues: (1) the vocal fold, which is a complex 3D structure with spatially controlled mechanical properties; and (2) musculoskeletal tissue interfaces, which are fibrous tissues with highly organized gradients in structure and chemistry. A tri-layered hydrogel scaffold was fabricated through layer-by-layer stacking to mimic the mechanical structure of the vocal fold. Furthermore, magnetically-assisted electrospinning and thiol-norbornene photochemistry was used to fabricate fibrous scaffolds that mimic the structural and chemical organization of musculoskeletal interfacial tissues. The work presented in this dissertation further advances the tissue engineering field by using innovative techniques to design scaffolds that recapitulate the natural complexity of native tissues.
ContributorsTindell, Raymond Kevin (Author) / Holloway, Julianne (Thesis advisor) / Green, Matthew (Committee member) / Pizziconi, Vincent (Committee member) / Stephanopoulos, Nicholas (Committee member) / Acharya, Abhinav (Committee member) / Arizona State University (Publisher)
Created2021
131779-Thumbnail Image.png
Description
This thesis aims to incorporate exosomes into an electrospun scaffold for tissue engineering applications. The motivation for this work is to develop an implant to regenerate tissue for patients with laryngeal defects. It was determined that it is feasible to incorporate exosomes into an electrospun scaffold. This addition of exosomes

This thesis aims to incorporate exosomes into an electrospun scaffold for tissue engineering applications. The motivation for this work is to develop an implant to regenerate tissue for patients with laryngeal defects. It was determined that it is feasible to incorporate exosomes into an electrospun scaffold. This addition of exosomes does alter the scaffold properties, by decreasing the average fiber diameter by roughly a factor of three and increasing the average modulus by roughly a factor of two. Cells were cultured on a scaffold with exosomes incorporated and were found to proliferate more than on a scaffold alone. This research lays the groundwork for further developing and optimizing an electrospun scaffold with exosomes incorporated to elicit a tissue regenerative response.
ContributorsKennedy, Maeve (Author) / Pizziconi, Vincent (Thesis director) / McPhail, Michael (Committee member) / School of International Letters and Cultures (Contributor) / Chemical Engineering Program (Contributor) / Barrett, The Honors College (Contributor)
Created2020-05