Matching Items (126)
Filtering by

Clear all filters

149790-Thumbnail Image.png
Description
Dr. Jerold D. Ottley's twenty-five years leading the Mormon Tabernacle Choir resulted in many distinguished awards and recognitions for the ensemble. Included among these are two Platinum and three Gold records from the Recording Industry Association of America, an Emmy from the Academy of Television Arts and Sciences, and two

Dr. Jerold D. Ottley's twenty-five years leading the Mormon Tabernacle Choir resulted in many distinguished awards and recognitions for the ensemble. Included among these are two Platinum and three Gold records from the Recording Industry Association of America, an Emmy from the Academy of Television Arts and Sciences, and two Freedom Foundation Awards for service to the country. He conducted the Choir at two presidential inaugurations, Ronald Reagan's in 1981 and George H. W. Bush's in 1989, as well as performances at the 1984 Los Angeles Olympics Gala. He presided over eleven international tours to twenty-six countries and crisscrossed the United States for engagements in nearly every region of the country. Despite the awards, commendations, and increased recognition of the Choir, Ottley's greatest contributions were largely internal to the organization. Jerold Ottley is a skilled music educator, administrator, and emissary. Application of these proficiencies while at the helm of the Choir, led to what are, arguably, his three largest contributions: 1) as educator, he instituted in-service training for choir members, raising the level of their individual musicianship, thereby improving the technical level of the entire Choir; 2) as administrator, Ottley created policies and procedures that resulted in a more disciplined, refined ensemble; and 3) as emissary, he raised the ensemble's reputation among the general public and with music professionals. For the general public, he significantly broadened the Choir's repertoire and traveled frequently thereby reaching a wider audience. He secured greater respect among music professionals by inviting many of them to work directly with the Choir. The results were unparalleled. Ottley's twenty-five year tenure with the Choir is reflected in broader audiences, increased professional acceptance, added organizational discipline, and unprecedented musical proficiency. It is a notable legacy for a man who reportedly never felt comfortable as director of the Mormon Tabernacle Choir.
ContributorsArchibald, Lyle Jay (Author) / Gentry, Gregory (Thesis advisor) / Britton, David (Committee member) / DeMars, James (Committee member) / Doan, Jerry (Committee member) / Solis, Theodore (Committee member) / Arizona State University (Publisher)
Created2011
150333-Thumbnail Image.png
Description
A systematic approach to composition has been used by a variety of composers to control an assortment of musical elements in their pieces. This paper begins with a brief survey of some of the important systematic approaches that composers have employed in their compositions, devoting particular attention to Pierre Boulez's

A systematic approach to composition has been used by a variety of composers to control an assortment of musical elements in their pieces. This paper begins with a brief survey of some of the important systematic approaches that composers have employed in their compositions, devoting particular attention to Pierre Boulez's Structures Ia . The purpose of this survey is to examine several systematic approaches to composition by prominent composers and their philosophy in adopting this type of approach. The next section of the paper introduces my own systematic approach to composition: the Take-Away System. The third provides several musical applications of the system, citing my work, Octulus for two pianos, as an example. The appendix details theorems and observations within the system for further study.
ContributorsHarbin, Doug (Author) / Hackbarth, Glenn (Thesis advisor) / DeMars, James (Committee member) / Etezady, Roshanne, 1973- (Committee member) / Rockmaker, Jody (Committee member) / Rogers, Rodney (Committee member) / Arizona State University (Publisher)
Created2011
149932-Thumbnail Image.png
Description
Recent changes in the energy markets structure combined with the conti-nuous load growth have caused power systems to be operated under more stressed conditions. In addition, the nature of power systems has also grown more complex and dynamic because of the increasing use of long inter-area tie-lines and the high

Recent changes in the energy markets structure combined with the conti-nuous load growth have caused power systems to be operated under more stressed conditions. In addition, the nature of power systems has also grown more complex and dynamic because of the increasing use of long inter-area tie-lines and the high motor loads especially those comprised mainly of residential single phase A/C motors. Therefore, delayed voltage recovery, fast voltage collapse and short term voltage stability issues in general have obtained significant importance in relia-bility studies. Shunt VAr injection has been used as a countermeasure for voltage instability. However, the dynamic and fast nature of short term voltage instability requires fast and sufficient VAr injection, and therefore dynamic VAr devices such as Static VAr Compensators (SVCs) and STATic COMpensators (STAT-COMs) are used. The location and size of such devices are optimized in order to improve their efficiency and reduce initial costs. In this work time domain dy-namic analysis was used to evaluate trajectory voltage sensitivities for each time step. Linear programming was then performed to determine the optimal amount of required VAr injection at each bus, using voltage sensitivities as weighting factors. Optimal VAr injection values from different operating conditions were weighted and averaged in order to obtain a final setting of the VAr requirement. Some buses under consideration were either assigned very small VAr injection values, or not assigned any value at all. Therefore, the approach used in this work was found to be useful in not only determining the optimal size of SVCs, but also their location.
ContributorsSalloum, Ahmed (Author) / Vittal, Vijay (Thesis advisor) / Heydt, Gerald (Committee member) / Ayyanar, Raja (Committee member) / Arizona State University (Publisher)
Created2011
149934-Thumbnail Image.png
Description
This research work describes the design of a fault current limiter (FCL) using digital logic and a microcontroller based data acquisition system for an ultra fast pilot protection system. These systems have been designed according to the requirements of the Future Renewable Electric Energy Delivery and Management (FREEDM) system (or

This research work describes the design of a fault current limiter (FCL) using digital logic and a microcontroller based data acquisition system for an ultra fast pilot protection system. These systems have been designed according to the requirements of the Future Renewable Electric Energy Delivery and Management (FREEDM) system (or loop), a 1 MW green energy hub. The FREEDM loop merges advanced power electronics technology with information tech-nology to form an efficient power grid that can be integrated with the existing power system. With the addition of loads to the FREEDM system, the level of fault current rises because of increased energy flow to supply the loads, and this requires the design of a limiter which can limit this current to a level which the existing switchgear can interrupt. The FCL limits the fault current to around three times the rated current. Fast switching Insulated-gate bipolar transistor (IGBT) with its gate control logic implements a switching strategy which enables this operation. A complete simulation of the system was built on Simulink and it was verified that the FCL limits the fault current to 1000 A compared to more than 3000 A fault current in the non-existence of a FCL. This setting is made user-defined. In FREEDM system, there is a need to interrupt a fault faster or make intelligent deci-sions relating to fault events, to ensure maximum availability of power to the loads connected to the system. This necessitates fast acquisition of data which is performed by the designed data acquisition system. The microcontroller acquires the data from a current transformer (CT). Mea-surements are made at different points in the FREEDM system and merged together, to input it to the intelligent protection algorithm that has been developed by another student on the project. The algorithm will generate a tripping signal in the event of a fault. The developed hardware and the programmed software to accomplish data acquisition and transmission are presented here. The designed FCL ensures that the existing switchgear equipments need not be replaced thus aiding future power system expansion. The developed data acquisition system enables fast fault sensing in protection schemes improving its reliability.
ContributorsThirumalai, Arvind (Author) / Karady, George G. (Thesis advisor) / Vittal, Vijay (Committee member) / Hedman, Kory (Committee member) / Arizona State University (Publisher)
Created2011
149797-Thumbnail Image.png
Description
Many of the works of Dominick Argento have been researched and analyzed, but his choral work Evensong: Of Love and Angels s has received limited attention thus far. Written in memoriam for his wife Carolyn Bailey Argento, Evensong draws its musical material from her initials C.B.A. These letters, translated into

Many of the works of Dominick Argento have been researched and analyzed, but his choral work Evensong: Of Love and Angels s has received limited attention thus far. Written in memoriam for his wife Carolyn Bailey Argento, Evensong draws its musical material from her initials C.B.A. These letters, translated into note names, form a conspicuous head motive that is present in each movement of the work, and it serves multiple functions: as a melodic feature, as the foundation for a twelve-tone row, and as a harmonic base. This paper provides an overview of the work's conception with specific relation to Argento's biographical details, compositional style, and work habits; a brief review of the critical reception of the work; and a succinct analysis of the form and cyclical materials found in each movement.
ContributorsPage, Carrie Leigh, 1980- (Author) / Rogers, Rodney (Thesis advisor) / DeMars, James (Committee member) / Levy, Benjamin (Committee member) / Oldani, Robert (Committee member) / Arizona State University (Publisher)
Created2011
149798-Thumbnail Image.png
Description
Everyday Arias for soprano and orchestra was composed largely in Arizona and completed in February 2011. The text was taken from a small collection of the composer's own poetry referencing her memories of life in rural Mississippi. Everyday Arias endeavors to elevate these prosaic experiences and settings to art, expressing

Everyday Arias for soprano and orchestra was composed largely in Arizona and completed in February 2011. The text was taken from a small collection of the composer's own poetry referencing her memories of life in rural Mississippi. Everyday Arias endeavors to elevate these prosaic experiences and settings to art, expressing the everyday as beautiful and worthy of artistic treatment. The primary compositional model for this work was Samuel Barber's Knoxville: Summer of 1915, but other influences included Charles Ives, Aaron Copland, Benjamin Britten, and Dominick Argento. Barber's and Argento's musical treatment of prose style seemed particularly appropriate to the goals of Everyday Arias. Ives and Copland used hymn tunes both to evoke certain associations of worship and as sources of interesting material. The vocal writing of all five composers was influential, but the orchestration techniques for winds are largely a product of studying Ives and Argento, while many string gestures are more obviously tied to Britten and - more historically - Debussy.The primary motive that weaves through the work features an ascending major second followed by a descending perfect fourth, in a long-short-long rhythmic pattern. As a melodic fragment, the motive is often inverted to a descending-ascending pattern, or distorted slightly by expanding the second interval to a perfect fifth, or used in retrograde. The motive was derived from the first measure of the melody "Toplady" (1830) by Thomas Hastings, better known as the hymn "Rock of Ages." In the first movement, the motive is used most frequently in sequences. The second movement treats the motive as a melodic element and as a unit in ostinati. The final movement humorously transforms it into a syncopated gesture to evoke ragtime.
ContributorsPage, Carrie Leigh (Composer) / Rogers, Rodney (Thesis advisor) / DeMars, James (Committee member) / Levy, Benjamin (Committee member) / Oldani, Robert (Committee member) / Arizona State University (Publisher)
Created2011
150247-Thumbnail Image.png
Description
The electric transmission grid is conventionally treated as a fixed asset and is operated around a single topology. Though several instances of switching transmission lines for corrective mechaism, congestion management, and minimization of losses can be found in literature, the idea of co-optimizing transmission with generation dispatch has not been

The electric transmission grid is conventionally treated as a fixed asset and is operated around a single topology. Though several instances of switching transmission lines for corrective mechaism, congestion management, and minimization of losses can be found in literature, the idea of co-optimizing transmission with generation dispatch has not been widely investigated. Network topology optimization exploits the redundancies that are an integral part of the network to allow for improvement in dispatch efficiency. Although, the concept of a dispatchable network initially appears counterintuitive questioning the wisdom of switching transmission lines on a more regu-lar basis, results obtained in the previous research on transmission switching with a Direct Current Optimal Power Flow (DCOPF) show significant cost reductions. This thesis on network topology optimization with ACOPF emphasizes the need for additional research in this area. It examines the performance of network topology optimization in an Alternating Current (AC) setting and its impact on various parameters like active power loss and voltages that are ignored in the DC setting. An ACOPF model, with binary variables representing the status of transmission lines incorporated into the formulation, is written in AMPL, a mathematical programming language and this optimization problem is solved using the solver KNITRO. ACOPF is a non-convex, nonlinear optimization problem, making it a very hard problem to solve. The introduction of bi-nary variables makes ACOPF a mixed integer nonlinear programming problem, further increasing the complexity of the optimization problem. An iterative method of opening each transmission line individually before choosing the best solution has been proposed as a purely investigative approach to studying the impact of transmission switching with ACOPF. Economic savings of up to 6% achieved using this approach indicate the potential of this concept. In addition, a heuristic has been proposed to improve the computational efficiency of network topology optimization. This research also makes a comparative analysis between transmission switching in a DC setting and switching in an AC setting. Results presented in this thesis indicate significant economic savings achieved by controlled topology optimization, thereby reconfirming the need for further examination of this idea.
ContributorsPotluri, Tejaswi (Author) / Hedman, Kory (Thesis advisor) / Vittal, Vijay (Committee member) / Heydt, Gerald (Committee member) / Arizona State University (Publisher)
Created2011
150298-Thumbnail Image.png
Description
Due to restructuring and open access to the transmission system, modern electric power systems are being operated closer to their operational limits. Additionally, the secure operational limits of modern power systems have become increasingly difficult to evaluate as the scale of the network and the number of transactions between utilities

Due to restructuring and open access to the transmission system, modern electric power systems are being operated closer to their operational limits. Additionally, the secure operational limits of modern power systems have become increasingly difficult to evaluate as the scale of the network and the number of transactions between utilities increase. To account for these challenges associated with the rapid expansion of electric power systems, dynamic equivalents have been widely applied for the purpose of reducing the computational effort of simulation-based transient security assessment. Dynamic equivalents are commonly developed using a coherency-based approach in which a retained area and an external area are first demarcated. Then the coherent generators in the external area are aggregated and replaced by equivalenced models, followed by network reduction and load aggregation. In this process, an improperly defined retained area can result in detrimental impacts on the effectiveness of the equivalents in preserving the dynamic characteristics of the original unreduced system. In this dissertation, a comprehensive approach has been proposed to determine an appropriate retained area boundary by including the critical generators in the external area that are tightly coupled with the initial retained area. Further-more, a systematic approach has also been investigated to efficiently predict the variation in generator slow coherency behavior when the system operating condition is subject to change. Based on this determination, the critical generators in the external area that are tightly coherent with the generators in the initial retained area are retained, resulting in a new retained area boundary. Finally, a novel hybrid dynamic equivalent, consisting of both a coherency-based equivalent and an artificial neural network (ANN)-based equivalent, has been proposed and analyzed. The ANN-based equivalent complements the coherency-based equivalent at all the retained area boundary buses, and it is designed to compensate for the discrepancy between the full system and the conventional coherency-based equivalent. The approaches developed have been validated on a large portion of the Western Electricity Coordinating Council (WECC) system and on a test case including a significant portion of the eastern interconnection.
ContributorsMa, Feng (Author) / Vittal, Vijay (Thesis advisor) / Tylavsky, Daniel (Committee member) / Heydt, Gerald (Committee member) / Si, Jennie (Committee member) / Ayyanar, Raja (Committee member) / Arizona State University (Publisher)
Created2011
150130-Thumbnail Image.png
Description
All-dielectric self-supporting (ADSS) fiber optic cables are used for data transfer by the utilities. They are installed along high voltage transmission lines. Dry band arcing, a phenomenon which is observed in outdoor insulators, is also observed in ADSS cables. The heat developed during dry band arcing damages the ADSS cables'

All-dielectric self-supporting (ADSS) fiber optic cables are used for data transfer by the utilities. They are installed along high voltage transmission lines. Dry band arcing, a phenomenon which is observed in outdoor insulators, is also observed in ADSS cables. The heat developed during dry band arcing damages the ADSS cables' outer sheath. A method is presented here to rate the cable sheath using the power developed during dry band arcing. Because of the small diameter of ADSS cables, mechanical vibration is induced in ADSS cable. In order to avoid damage, vibration dampers known as spiral vibration dampers (SVD) are used over these ADSS cables. These dampers are installed near the armor rods, where the presence of leakage current and dry band activity is more. The effect of dampers on dry band activity is investigated by conducting experiments on ADSS cable and dampers. Observations made from the experiments suggest that the hydrophobicity of the cable and damper play a key role in stabilizing dry band arcs. Hydrophobic-ity of the samples have been compared. The importance of hydrophobicity of the samples is further illustrated with the help of simulation results. The results indi-cate that the electric field increases at the edges of water strip. The dry band arc-ing phenomenon could thus be correlated to the hydrophobicity of the outer sur-face of cable and damper.
ContributorsPrabakar, Kumaraguru (Author) / Karady, George G. (Thesis advisor) / Vittal, Vijay (Committee member) / Ayyanar, Raja (Committee member) / Arizona State University (Publisher)
Created2011
150094-Thumbnail Image.png
Description
The high penetration of photovoltaic (PV) both at the utility and at the distribu-tion levels, has raised concerns about the reliability of grid-tied inverters of PV power systems. Inverters are generally considered as the weak link in PV power systems. The lack of a dedicated qualification/reliability standard for PV inverters

The high penetration of photovoltaic (PV) both at the utility and at the distribu-tion levels, has raised concerns about the reliability of grid-tied inverters of PV power systems. Inverters are generally considered as the weak link in PV power systems. The lack of a dedicated qualification/reliability standard for PV inverters is a main barrier in realizing higher level of confidence in reliability. Development of a well-accepted design qualification standard specifically for PV inverters will help pave the way for significant improvement in reliability and performance of inverters across the entire industry. The existing standards for PV inverters such as UL 1741 and IEC 62109-1 primarily focus on safety. IEC 62093 discusses inverter qualification but it includes all the balance of sys-tem components and therefore not specific to PV inverters. There are other general stan-dards for distributed generators including the IEEE1547 series of standards which cover major concerns like utility integration but they are not dedicated to PV inverters and are not written from a design qualification point of view. In this thesis, some of the potential requirements for a design qualification standard for PV inverters are addressed. The IEC 62093 is considered as a guideline and the possible inclusions in the framework for a dedicated design qualification standard of PV inverter are discussed. The missing links in existing PV inverter related standards are identified by performing gap analysis. Dif-ferent requirements of small residential inverters compared to large utility-scale systems, and the emerging requirements on grid support features are also considered. Electric stress test is found to be the key missing link and one of the electric stress tests, the surge withstand test is studied in detail. The use of the existing standards for surge withstand test of residential scale PV inverters is investigated and a method to suitably adopt these standards is proposed. The proposed method is studied analytically and verified using simulation. A design criterion for choosing the switch ratings of the inverter that can per-form reliably under the surge environment is derived.
ContributorsAlampoondi Venkataramanan, Sai Balasubramanian (Author) / Ayyanar, Raja (Thesis advisor) / Vittal, Vijay (Committee member) / Heydt, Gerald (Committee member) / Arizona State University (Publisher)
Created2011