Matching Items (3)
Filtering by

Clear all filters

156204-Thumbnail Image.png
Description
The human hand comprises complex sensorimotor functions that can be impaired by neurological diseases and traumatic injuries. Effective rehabilitation can bring the impaired hand back to a functional state because of the plasticity of the central nervous system to relearn and remodel the lost synapses in the brain. Current rehabilitation

The human hand comprises complex sensorimotor functions that can be impaired by neurological diseases and traumatic injuries. Effective rehabilitation can bring the impaired hand back to a functional state because of the plasticity of the central nervous system to relearn and remodel the lost synapses in the brain. Current rehabilitation therapies focus on strengthening motor skills, such as grasping, employ multiple objects of varying stiffness and devices that are bulky, costly, and have limited range of stiffness due to the rigid mechanisms employed in their variable stiffness actuators. This research project presents a portable cost-effective soft robotic haptic device with a broad stiffness range that is adjustable and can be utilized in both clinical and home settings. The device eliminates the need for multiple objects by employing a pneumatic soft structure made with highly compliant materials that act as the actuator as well as the structure of the haptic interface. It is made with interchangeable soft elastomeric sleeves that can be customized to include materials of varying stiffness to increase or decrease the stiffness range. The device is fabricated using existing 3D printing technologies, and polymer molding and casting techniques, thus keeping the cost low and throughput high. The haptic interface is linked to either an open-loop system that allows for an increased pressure during usage or closed-loop system that provides pressure regulation in accordance with the stiffness the user specifies. A preliminary evaluation is performed to characterize the effective controllable region of variance in stiffness. Results indicate that the region of controllable stiffness was in the center of the device, where the stiffness appeared to plateau with each increase in pressure. The two control systems are tested to derive relationships between internal pressure, grasping force exertion on the surface, and displacement using multiple probing points on the haptic device. Additional quantitative evaluation is performed with study participants and juxtaposed to a qualitative analysis to ensure adequate perception in compliance variance. Finally, a qualitative evaluation showed that greater than 60% of the trials resulted in the correct perception of stiffness in the haptic device.
ContributorsSebastian, Frederick (Author) / Polygerinos, Panagiotis (Thesis advisor) / Santello, Marco (Committee member) / Fu, Qiushi (Committee member) / Arizona State University (Publisher)
Created2018
171660-Thumbnail Image.png
Description
With an aging population, the number of later in life health related incidents like stroke stand to become more prevalent. Unfortunately, the majority those who are most at risk for debilitating heath episodes are either uninsured or under insured when it comes to long term physical/occupational therapy. As insurance companies

With an aging population, the number of later in life health related incidents like stroke stand to become more prevalent. Unfortunately, the majority those who are most at risk for debilitating heath episodes are either uninsured or under insured when it comes to long term physical/occupational therapy. As insurance companies lower coverage and/or raise prices of plans with sufficient coverage, it can be expected that the proportion of uninsured/under insured to fully insured people will rise. To address this, lower cost alternative methods of treatment must be developed so people can obtain the treated required for a sufficient recovery. The presented robotic glove employs low cost fabric soft pneumatic actuators which use a closed loop feedback controller based on readings from embedded soft sensors. This provides the device with proprioceptive abilities for the dynamic control of each independent actuator. Force and fatigue tests were performed to determine the viability of the actuator design. A Box and Block test along with a motion capture study was completed to study the performance of the device. This paper presents the design and classification of a soft robotic glove with a feedback controller as a at-home stroke rehabilitation device.
ContributorsAxman, Reed C (Author) / Zhang, Wenlong (Thesis advisor) / Santello, Marco (Committee member) / McDaniel, Troy (Committee member) / Arizona State University (Publisher)
Created2022
161512-Thumbnail Image.png
Description
Stroke occurs when the blood supply to part of the brain is interrupted or reduced, preventing brain tissue from getting oxygen and nutrients, thus causing brain cells to die. Stroke is the 5th leading cause of death in the United States and is one of the major causes of disability.

Stroke occurs when the blood supply to part of the brain is interrupted or reduced, preventing brain tissue from getting oxygen and nutrients, thus causing brain cells to die. Stroke is the 5th leading cause of death in the United States and is one of the major causes of disability. Conventional therapy is a form of stroke rehabilitation generally consisting of physical and occupational therapy. It focuses on customized exercises based on the patient’s feedback. Physical therapy includes exercises such as weight bearing (affected arm), vibration of affected muscle and gravity-eliminated movement of affected arm. Overall physical therapy aims at strengthening muscle groups and aides in the relearning process. Occupational aspect of conventional therapy includes activities of daily living (ADL) such as dressing, self-feeding, grooming and toileting. Overall occupational therapy focuses on improving the daily activities performed by individuals. In comparison to conventional therapy, robotic therapy is relatively newer therapy. It uses robotic devices to perform repetitive motions and delivers high dosage and high intensity training to stroke patients. Based on the research studies reviewed, it is known that neuroplasticity in stroke patients is linked to interventions which are high in dosage, intensity, repetition, difficulty, salience. Peer-reviewed literature suggests robotic therapy might be a viable option for recovery in stroke patients. However, the extent to which robotic therapy may provide greater benefits than conventional therapy remains unclear. This thesis addresses the key components of a study design for comparing the efficacy of robotic therapy relative to conventional therapy to improve upper limb sensorimotor function in stroke survivors. The study design is based on an extensive review of the literature of stroke clinical trials and robotic therapy studies, analyses of the capabilities of a robotic therapy device (M2, Fourier Intelligence), and pilot data collected on healthy controls to create a pipeline of tasks and analyses to extract biomarkers of sensorimotor functional changes. This work has laid the foundation for a pilot longitudinal study that will be conducted at the Barrow Neurological Institute, Phoenix, AZ, where conventional and robotic therapy will be compared in a small cohort of stroke survivors.
ContributorsThomas, Lovein (Author) / Santello, Marco (Thesis advisor) / Kleim, Jeffrey (Committee member) / Maruyama, Trent (Committee member) / Arizona State University (Publisher)
Created2021