Matching Items (5)
Filtering by

Clear all filters

135820-Thumbnail Image.png
Description
This paper proposes a new framework design for the lightweight transradial prosthesis. This device was designed to be light-weight, easily manufactured, inexpensive, and to have a high interstitial free space volume for electrical components and customization. Press-fit junctions between fins allow for little or no adhesives, allowing for easily replaceable

This paper proposes a new framework design for the lightweight transradial prosthesis. This device was designed to be light-weight, easily manufactured, inexpensive, and to have a high interstitial free space volume for electrical components and customization. Press-fit junctions between fins allow for little or no adhesives, allowing for easily replaceable parts. Designs were constructed out of chipboard and run through an assortment of tests to see if each design iterations met structural design specifications. There were four main design iterations tested: 4, 8, 12 fin designs, and a 4 fin design with additional angled fins for torsional support (4T). Compression, torsion, and 3-point bending tests were all performed on each cylindrical iteration. Basic tensile and material testing was done on chipboard to support results. The force applied to a human arm during a fall is approximately 500 lbf [13]. Compression tests yielded a strength of approximately 300 lbf for the cylindrical designs. ANOVAs and T-tests were performed to find significance in compressive strength between the design iterations with the varied number of fins (p<<0.05). The torsional strength of the human arm, without causing great strain or discomfort has a max value of approximately 15 Nm [14]. This matched the torsional values of the 4T. design [14]. The 4, 8, and 12 designs' torsional strengths were linear with values of approximately 4, 7, and 12 Nm respectively. The 3-point bending test yielded the flexural stress and strain values to find compressive strength in the convex direction as well as the displacement and deformation in each sample. The material chipboard was found to be variable with elastic modulus, Poisson's ratio, and tensile strength. Each experimental procedure was done as a proof of concept for future prosthesis design.
ContributorsMcbryan, Sarah Jane (Author) / LaBelle, Jeffrey (Thesis director) / Lathers, Steven (Committee member) / Harrington Bioengineering Program (Contributor) / Barrett, The Honors College (Contributor)
Created2016-05
Description
The action/adventure game Grad School: HGH is the final, extended version of a BME Prototyping class project in which the goal was to produce a zombie-themed game that teaches biomedical engineering concepts. The gameplay provides fast paced, exciting, and mildly addicting rooms that the player must battle and survive through,

The action/adventure game Grad School: HGH is the final, extended version of a BME Prototyping class project in which the goal was to produce a zombie-themed game that teaches biomedical engineering concepts. The gameplay provides fast paced, exciting, and mildly addicting rooms that the player must battle and survive through, followed by an engineering puzzle that must be solved in order to advance to the next room. The objective of this project was to introduce the core concepts of BME to prospective students, rather than attempt to teach an entire BME curriculum. Based on user testing at various phases in the project, we concluded that the gameplay was engaging enough to keep most users' interest through the educational puzzles, and the potential for expanding this project to reach an even greater audience is vast.
ContributorsNitescu, George (Co-author) / Medawar, Alexandre (Co-author) / Spano, Mark (Thesis director) / LaBelle, Jeffrey (Committee member) / Guiang, Kristoffer (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor)
Created2014-05
134397-Thumbnail Image.png
Description
This paper proposes a new socket design to complement Project Fishbone, a design project focused on creating a lightweight transradial prosthetic device. The socket has a simple concept of introducing perforations on the surface of the socket using cost effective, and rapid manufacturing methods such as vacuum thermoforming and drilling.

This paper proposes a new socket design to complement Project Fishbone, a design project focused on creating a lightweight transradial prosthetic device. The socket has a simple concept of introducing perforations on the surface of the socket using cost effective, and rapid manufacturing methods such as vacuum thermoforming and drilling. The perforations on the socket allows for greater air ventilation to the prosthetic user's residual skin thus reducing the temperature within the socket. There were nine primary design iterations that were tested: 0.125, 0,187, 0.25-inch-thick designs, and 3/16, 15/64, 17/64-inch perforation sizes, and 12, 18 and 24 count of perforations. Initial test was done using the sockets of different thickness without any perforations to check for uniformity in design and manufacturing method using a regression test. It was found that an increase in thickness directly related to an increase in temperature cooling time. The temperature cooling test was run using a three-factor DOE method and no clear interaction between the factors was observed, thus the Kruskal-Wallis statistical test along with the post hoc Mann-Whitney test to check for significance among the factors as well as significance of groups within the factors. Statistical significance (p<0.05) was found in the socket thickness and size of perforations. Additionally, significance (p<0.02) was found in the 0.125 and 0.187-inch thickness and the 3/16-inch size perforations. Based on the significance between each group, the best combination for increased cooling time reduction was thus found to be with the 0.125-inch thick HDPE sheet and 3/16-inch sized perforation while the number of perforations did not make much difference. These results proved the concept of this new socket design that could be implemented into existing upper limb prosthetic systems.
ContributorsSebastian, Frederick (Author) / LaBelle, Jeffrey (Thesis director) / Lathers, Steven (Committee member) / Harrington Bioengineering Program (Contributor, Contributor) / Barrett, The Honors College (Contributor)
Created2017-05
154931-Thumbnail Image.png
Description
This thesis dissertation presents design of portable low power Electrochemical Impedance Spectroscopy (EIS) system which can be used for biomedical applications such as tear diagnosis, blood diagnosis, or any other body-fluid diagnosis. Two design methodologies are explained in this dissertation (a) a discrete component-based portable low-power EIS system and (b)

This thesis dissertation presents design of portable low power Electrochemical Impedance Spectroscopy (EIS) system which can be used for biomedical applications such as tear diagnosis, blood diagnosis, or any other body-fluid diagnosis. Two design methodologies are explained in this dissertation (a) a discrete component-based portable low-power EIS system and (b) an integrated CMOS-based portable low-power EIS system. Both EIS systems were tested in a laboratory environment and the characterization results are compared. The advantages and disadvantages of the integrated EIS system relative to the discrete component-based EIS system are presented including experimental data. The specifications of both EIS systems are compared with commercially available non-portable EIS workstations. These designed EIS systems are handheld and very low-cost relative to the currently available commercial EIS workstations.
ContributorsGhorband, Vishal (Author) / Blain Christen, Jennifer (Thesis advisor) / Song, Hongjiang (Committee member) / LaBelle, Jeffrey (Committee member) / Arizona State University (Publisher)
Created2016
151306-Thumbnail Image.png
Description
Over the past fifty years, the development of sensors for biological applications has increased dramatically. This rapid growth can be attributed in part to the reduction in feature size, which the electronics industry has pioneered over the same period. The decrease in feature size has led to the production of

Over the past fifty years, the development of sensors for biological applications has increased dramatically. This rapid growth can be attributed in part to the reduction in feature size, which the electronics industry has pioneered over the same period. The decrease in feature size has led to the production of microscale sensors that are used for sensing applications, ranging from whole-body monitoring down to molecular sensing. Unfortunately, sensors are often developed without regard to how they will be integrated into biological systems. The complexities of integration are underappreciated. Integration involves more than simply making electrical connections. Interfacing microscale sensors with biological environments requires numerous considerations with respect to the creation of compatible packaging, the management of biological reagents, and the act of combining technologies with different dimensions and material properties. Recent advances in microfluidics, especially the proliferation of soft lithography manufacturing methods, have established the groundwork for creating systems that may solve many of the problems inherent to sensor-fluidic interaction. The adaptation of microelectronics manufacturing methods, such as Complementary Metal-Oxide-Semiconductor (CMOS) and Microelectromechanical Systems (MEMS) processes, allows the creation of a complete biological sensing system with integrated sensors and readout circuits. Combining these technologies is an obstacle to forming complete sensor systems. This dissertation presents new approaches for the design, fabrication, and integration of microscale sensors and microelectronics with microfluidics. The work addresses specific challenges, such as combining commercial manufacturing processes into biological systems and developing microscale sensors in these processes. This work is exemplified through a feedback-controlled microfluidic pH system to demonstrate the integration capabilities of microscale sensors for autonomous microenvironment control.
ContributorsWelch, David (Author) / Blain Christen, Jennifer (Thesis advisor) / Muthuswamy, Jitendran (Committee member) / Frakes, David (Committee member) / LaBelle, Jeffrey (Committee member) / Goryll, Michael (Committee member) / Arizona State University (Publisher)