150385-Thumbnail Image.png
Description
In nearly all commercially successful internal combustion engine applications, the slider crank mechanism is used to convert the reciprocating motion of the piston into rotary motion. The hypocycloid mechanism, wherein the crankshaft is replaced with a novel gearing arrangement, is a viable alternative to the slider crank mechanism. The geared

In nearly all commercially successful internal combustion engine applications, the slider crank mechanism is used to convert the reciprocating motion of the piston into rotary motion. The hypocycloid mechanism, wherein the crankshaft is replaced with a novel gearing arrangement, is a viable alternative to the slider crank mechanism. The geared hypocycloid mechanism allows for linear motion of the connecting rod and provides a method for perfect balance with any number of cylinders including single cylinder applications. A variety of hypocycloid engine designs and research efforts have been undertaken and produced successful running prototypes. Wiseman Technologies, Inc provided one of these prototypes to this research effort. This two-cycle 30cc half crank hypocycloid engine has shown promise in several performance categories including balance and efficiency. To further investigate its potential a more thorough and scientific analysis was necessary and completed in this research effort. The major objective of the research effort was to critically evaluate and optimize the Wiseman prototype for maximum performance in balance, efficiency, and power output. A nearly identical slider crank engine was used extensively to establish baseline performance data and make comparisons. Specialized equipment and methods were designed and built to collect experimental data on both engines. Simulation and mathematical models validated by experimental data collection were used to better quantify performance improvements. Modifications to the Wiseman prototype engine improved balance by 20 to 50% (depending on direction) and increased peak power output by 24%.
ContributorsConner, Thomas (Author) / Redkar, Sangram (Thesis advisor) / Rogers, Bradley (Committee member) / Georgeou, Trian (Committee member) / Arizona State University (Publisher)
Created2011
155947-Thumbnail Image.png
Description
In this work, different passive prosthetic ankles are studied. It is observed that complicated designs increase the cost of production, but simple designs have limited functionality. A new design for a passive prosthetic ankle is presented that is simple to manufacture while having superior functionality. This prosthetic ankle design has

In this work, different passive prosthetic ankles are studied. It is observed that complicated designs increase the cost of production, but simple designs have limited functionality. A new design for a passive prosthetic ankle is presented that is simple to manufacture while having superior functionality. This prosthetic ankle design has two springs: one mimicking Achilles tendon and the other mimicking Anterior-Tibialis tendon. The dynamics of the prosthetic ankle is discussed and simulated using Working model 2D. The simulation results are used to optimize the springs stiffness. Two experiments are conducted using the developed ankle to verify the simulation It is found that this novel ankle design is better than Solid Ankle Cushioned Heel (SACH) foot. The experimental data is used to find the tendon and muscle activation forces of the subject wearing the prosthesis using OpenSim. A conclusion is included along with suggested future work.
ContributorsBhat, Sandesh Ganapati (Author) / Redkar, Sangram (Thesis advisor) / Sugar, Thomas (Committee member) / Lee, Hyuglae (Committee member) / Marvi, Hamid (Committee member) / Arizona State University (Publisher)
Created2017
168360-Thumbnail Image.png
Description
As the world moves towards faster production times, quicker shipping, and overall, more demanding schedules, the humans caught in the loop are subject to physical duress causing them to physically break down and have muscular skeletal injuries. Surprisingly, with more automation in logistics houses, the remaining workers must be quicker

As the world moves towards faster production times, quicker shipping, and overall, more demanding schedules, the humans caught in the loop are subject to physical duress causing them to physically break down and have muscular skeletal injuries. Surprisingly, with more automation in logistics houses, the remaining workers must be quicker and do more, again resulting in muscular-skeletal injuries. To help alleviate this strain, a class of robotics and wearables has arisen wherein the human is assisted by a worn mechanical device. These devices, traditionally called exoskeletons, fall into two general categories: passive and active. Passive exoskeletons employ no electronics to activate their assistance and instead typically rely on the spring-like qualities of many materials. These are generally lighter weight than their active counterparts, but also lack the assistive power and can even interfere in other routine operations. Active exoskeletons, on the other hand, aim to avoid as much interference as possible by using electronics and power to assist the wearer. Properly executed, this can deliver power at the most opportune time and disengage from interference when not needed. However, if the tuning is mismatched from the human, it can unintentionally increase loads and possibly lead to other future injuries or harm. This dissertation investigates exoskeleton technology from two vantage points: the designer and the consumer. In the first, the creation of the Aerial Porter Exoskeleton (APEx) for the US Air Force (USAF). Testing of this first of its kind exoskeleton revealed a peak metabolic savings of 8.13% as it delivers 30 N-m of torque about each hip. It was tested extensively in live field conditions over 8 weeks to great success. The second section is an exploration of different commercially available exoskeletons and the development of a common set of standards/testing protocols is described. The results show a starting point for a set of standards to be used in a rapidly growing sector.
ContributorsMartin, William Brandon (Author) / Sugar, Thomas (Thesis advisor) / Redkar, Sangram (Thesis advisor) / Hollander, Kevin (Committee member) / Arizona State University (Publisher)
Created2021