Matching Items (3)
Filtering by

Clear all filters

148477-Thumbnail Image.png
Description

The purpose of this study is to collect baseline internal and external pressure data for the three most commonly used pelvic circumferential compression devices (PCCD). Unstable pelvic fractures as a result of automobile accidents, falls, and other traumatic injuries mortality rate [3]. Early use of pelvic circumferential compression devices can

The purpose of this study is to collect baseline internal and external pressure data for the three most commonly used pelvic circumferential compression devices (PCCD). Unstable pelvic fractures as a result of automobile accidents, falls, and other traumatic injuries mortality rate [3]. Early use of pelvic circumferential compression devices can mitigate fatal outcomes [4]-[5]. Prolonged eternal pressure above 9.3kPa can result in long-term soft tissue damage and pressure ulcers [7]. This study hypothesizes that the application of the three most commonly used PCCDs would result in the same mean maximum point pressure exertion. To study this, internal and external, both analog and digital, pressure apparati were used to collect data. The results of this data collection demonstrate a discrepancy in the pressure distribution between right and left greater trochanters within each PCCD. Additionally, the results suggest there is an effect of internal packing on the pressure exertion externally at the two greater trochanters within each PCCD. Lastly, the differences in pressure exertion between each PCCD, internally and externally, were inconclusive as some compared metrics resulted in statistically significant results while others did not. The methodologies employed in this study can be improved through fixation of pressure collection instruments, utilization of digital pressure mats, and removal of confounding factors. The results of this study indicate that digitized, discrete data over a fixed time interval may be clinically useful, suggesting that a digital data collection would yield more reliable data. Additionally, internally mounted pressure sensor data will provide more precise results than the analog method employed herein, as well as provide insight towards bone reduction and displacement following the application of PCCDs. Finally, the information gathered from this study can be utilized to improve upon existing technologies to create a more innovative solution.

ContributorsMoore, Kameron James (Co-author) / Dewald, Alison (Co-author) / Pizziconi, Vincent (Thesis director) / Bogert, James (Committee member) / Harrington Bioengineering Program (Contributor) / School of International Letters and Cultures (Contributor) / Barrett, The Honors College (Contributor)
Created2021-05
148478-Thumbnail Image.png
Description

The purpose of this study is to collect baseline internal and external pressure data for the three most commonly used pelvic circumferential compression devices (PCCD). Unstable pelvic fractures as a result of automobile accidents, falls, and other traumatic injuries mortality rate [3]. Early use of pelvic circumferential compression devices can

The purpose of this study is to collect baseline internal and external pressure data for the three most commonly used pelvic circumferential compression devices (PCCD). Unstable pelvic fractures as a result of automobile accidents, falls, and other traumatic injuries mortality rate [3]. Early use of pelvic circumferential compression devices can mitigate fatal outcomes [4]-[5]. Prolonged eternal pressure above 9.3kPa can result in long-term soft tissue damage and pressure ulcers [7]. This study hypothesizes that the application of the three most commonly used PCCDs would result in the same mean maximum point pressure exertion. To study this, internal and external, both analog and digital, pressure apparati were used to collect data. The results of this data collection demonstrate a discrepancy in the pressure distribution between right and left greater trochanters within each PCCD. Additionally, the results suggest there is an effect of internal packing on the pressure exertion externally at the two greater trochanters within each PCCD. Lastly, the differences in pressure exertion between each PCCD, internally and externally, were inconclusive as some compared metrics resulted in statistically significant results while others did not. The methodologies employed in this study can be improved through fixation of pressure collection instruments, utilization of digital pressure mats, and removal of confounding factors. The results of this study indicate that digitized, discrete data over a fixed time interval may be clinically useful, suggesting that a digital data collection would yield more reliable data. Additionally, internally mounted pressure sensor data will provide more precise results than the analog method employed herein, as well as provide insight towards bone reduction and displacement following the application of PCCDs. Finally, the information gathered from this study can be utilized to improve upon existing technologies to create a more innovative solution.

Created2021-05
154250-Thumbnail Image.png
Description
“Trauma, Typology, and Anti-Catholicism in Early Modern England” explores the connection between the biblical exegetical mode of typology and the construction of traumatic historiography in early modern English anti-Catholicism. The Protestant use of typology—for example, linking Elizabeth to Eve--was a textual expression of political and religious trauma surrounding the English

“Trauma, Typology, and Anti-Catholicism in Early Modern England” explores the connection between the biblical exegetical mode of typology and the construction of traumatic historiography in early modern English anti-Catholicism. The Protestant use of typology—for example, linking Elizabeth to Eve--was a textual expression of political and religious trauma surrounding the English Reformation and responded to the threat presented by foreign and domestic Catholicism between 1579 and 1625. During this period of the Elizabethan and Jacobean eras, English anti-Catholicism began to encompass not only doctrine, but stereotypical representations of Catholics and their desire to overthrow Protestant sovereignty. English Protestant polemicists viewed themselves as taking part in an important hermeneutical process that allowed their readers to understand the role of the past in the present. Viewing English anti-Catholicism through the lens of trauma studies allows us greater insight into the beliefs that underpinned this religio-political rhetoric.

Much of this rhetorical use of typology generated accessible associations of Catholics with both biblical villains and with officials who persecuted and executed Protestants during the reign of Mary I. These associations created a typological network that reinforced the notion of English Protestants as an elect people, while at the same time exploring Protestant religio-political anxiety in the wake of various Catholic plots. Each chapter explores texts published in moments of Catholic “crisis” wherein typology and trauma form a recursive loop by which the parameters of the threat can be understood. The first chapter examines John Stubbs’s Discovery of a Gaping Gulf (1579) and his views of Protestant female monarchy and a sexualized Catholic threat in response to Elizabeth I’s proposed marriage to the French Catholic Duke of Anjou. The second chapter surveys popular and state responses to the first Jesuit mission to England in 1580. The final chapters consider the place of typology and trauma in works by mercantilist Thomas Milles in response to recusant equivocation following the thwarting of the Gunpowder Plot in 1605 and in Thomas Middleton’s A Game at Chess (1624) as a response to the failure of marriage negotiations between the Protestant Prince Charles and the Catholic Spanish Infanta.
ContributorsKimbro, Devori (Author) / Hawkes, David (Thesis advisor) / Fox, Cora (Thesis advisor) / Ryner, Bradley (Committee member) / Irish, Bradley (Committee member) / Arizona State University (Publisher)
Created2015