Filtering by
- Creators: Barrett, The Honors College
While the poems illustrate the complexity of one’s experience with both PTSD and its stages of recovery (e.g., emergency, numbness, intrusive/repetitive, integration), they are anchored in the sensory, the concrete. Amidst the terror of the symptoms at the most basic, raw level, she attempts to reclaim selfhood, which involves wrestling with philosophical suicide, reconciling realities, numbness and the widening of a barrier, stunning intimacies, the craving to feel, and both the desire and the need to connect authentically without being able to satiate such inclinations.
Influenced by the works of Frank Bidart, Claudia Rankine, James Longenbach, and Carolyn Forché, the pieces rely heavily upon rhythm and spacing, imagery, and associative linkages throughout the work to craft a sense of physical, intellectual, and emotional movement within the space.
The collection focuses upon the narrative of one survivor of trauma, and though traumas may be experienced differently, and while PTSD may manifest itself in profoundly diverse ways, the pieces aim to capture the shared foundation of the experience — the isolation and the pure, unadulterated pain — in order to cast a universal veil onto the exploration, providing the audience with insight into one of trauma’s most important facets.
The purpose of this study is to collect baseline internal and external pressure data for the three most commonly used pelvic circumferential compression devices (PCCD). Unstable pelvic fractures as a result of automobile accidents, falls, and other traumatic injuries mortality rate [3]. Early use of pelvic circumferential compression devices can mitigate fatal outcomes [4]-[5]. Prolonged eternal pressure above 9.3kPa can result in long-term soft tissue damage and pressure ulcers [7]. This study hypothesizes that the application of the three most commonly used PCCDs would result in the same mean maximum point pressure exertion. To study this, internal and external, both analog and digital, pressure apparati were used to collect data. The results of this data collection demonstrate a discrepancy in the pressure distribution between right and left greater trochanters within each PCCD. Additionally, the results suggest there is an effect of internal packing on the pressure exertion externally at the two greater trochanters within each PCCD. Lastly, the differences in pressure exertion between each PCCD, internally and externally, were inconclusive as some compared metrics resulted in statistically significant results while others did not. The methodologies employed in this study can be improved through fixation of pressure collection instruments, utilization of digital pressure mats, and removal of confounding factors. The results of this study indicate that digitized, discrete data over a fixed time interval may be clinically useful, suggesting that a digital data collection would yield more reliable data. Additionally, internally mounted pressure sensor data will provide more precise results than the analog method employed herein, as well as provide insight towards bone reduction and displacement following the application of PCCDs. Finally, the information gathered from this study can be utilized to improve upon existing technologies to create a more innovative solution.
The purpose of this study is to collect baseline internal and external pressure data for the three most commonly used pelvic circumferential compression devices (PCCD). Unstable pelvic fractures as a result of automobile accidents, falls, and other traumatic injuries mortality rate [3]. Early use of pelvic circumferential compression devices can mitigate fatal outcomes [4]-[5]. Prolonged eternal pressure above 9.3kPa can result in long-term soft tissue damage and pressure ulcers [7]. This study hypothesizes that the application of the three most commonly used PCCDs would result in the same mean maximum point pressure exertion. To study this, internal and external, both analog and digital, pressure apparati were used to collect data. The results of this data collection demonstrate a discrepancy in the pressure distribution between right and left greater trochanters within each PCCD. Additionally, the results suggest there is an effect of internal packing on the pressure exertion externally at the two greater trochanters within each PCCD. Lastly, the differences in pressure exertion between each PCCD, internally and externally, were inconclusive as some compared metrics resulted in statistically significant results while others did not. The methodologies employed in this study can be improved through fixation of pressure collection instruments, utilization of digital pressure mats, and removal of confounding factors. The results of this study indicate that digitized, discrete data over a fixed time interval may be clinically useful, suggesting that a digital data collection would yield more reliable data. Additionally, internally mounted pressure sensor data will provide more precise results than the analog method employed herein, as well as provide insight towards bone reduction and displacement following the application of PCCDs. Finally, the information gathered from this study can be utilized to improve upon existing technologies to create a more innovative solution.
This project is a critical analysis of the works of 6 American war veterans and how they demonstrate trauma in their narratives. The texts covered here are Philip Red Eagle’s Red Earth (2007), John A. Williams’ Captain Blackman (1972), Roy Scranton’s War Porn (2016), Tim O’Brien’s The Things They Carried (1990), Kurt Vonnegut’s Slaughterhouse-Five (1969), and Joseph Heller’s Catch-22 (1961).