Matching Items (3)
Filtering by

Clear all filters

154132-Thumbnail Image.png
Description
The purpose of this study was to determine the applicability of fluorescent microspheres as a surrogate to measure the removal of Cryptosporidium oocysts through the coagulation, flocculation, sedimentation, and filtration steps of conventional water treatment. In order to maintain accuracy and applicability, a local water treatment facility was chosen as

The purpose of this study was to determine the applicability of fluorescent microspheres as a surrogate to measure the removal of Cryptosporidium oocysts through the coagulation, flocculation, sedimentation, and filtration steps of conventional water treatment. In order to maintain accuracy and applicability, a local water treatment facility was chosen as the system to model. The city of Chandler Arizona utilizes conventional treatment methodologies to remove pathogens from municipal drinking water and thus the water, coagulant, polymer, and doses concentrations were sourced directly from the plant. Jar testing was performed on four combinations of coagulant, polymer, and fluorescent microsphere to determine if the log removal was similar to that of Cryptosporidium oocysts.

Complications with the material properties of the microspheres arose during testing that ultimately yielded unfavorable but conclusive results. Log removal of microspheres did not increase with added coagulant in the predicted manner, though the beads were seen aggregating, the low density of the particles made the sedimentation step inefficient. This result can be explained by the low density of the microspheres as well as the potential presence of residual coagulant present in the system. Given the unfavorable properties of the beads, they do not appear to be a suitable candidate for the surrogacy of Cryptosporidium oocysts in conventional drinking water treatment. The beads in their current state are not an adequate surrogate; however, future testing has been outlined to modify the experiment in such a way that the microspheres should behave like oocysts in terms of physical transportation.
ContributorsLinks, Alexander Glenn (Author) / Abbaszadegan, Morteza (Thesis advisor) / Alum, Absar (Committee member) / Fox, Peter (Committee member) / Arizona State University (Publisher)
Created2015
171533-Thumbnail Image.png
Description
Corrosion is known to have severe infrastructure integrity implications in a broad range of industries including water and wastewater treatment and reclamation. In the U.S. alone, the total losses due to corrosion in drinking water and wastewater systems can account for economic losses as high as $80 billion dollars a

Corrosion is known to have severe infrastructure integrity implications in a broad range of industries including water and wastewater treatment and reclamation. In the U.S. alone, the total losses due to corrosion in drinking water and wastewater systems can account for economic losses as high as $80 billion dollars a year. Microbially induced corrosion is a complex phenomenon which involve various phases; 1) formation of biofilms on submerged surfaces, 2) creation of micro-environmental niches associated with biofilm growth, 3) altered availability nutrients, 4) changes in the pH and oxygen concentrations. Biofilms can harbor opportunistic or pathogenic bacteria for a long time increasing the risk of pathogen exposure for the end users. The focus of this thesis research was to study the kinetics of microbially induced corrosion of various materials in water and reclaimed water systems. The specific objective was to assess the biofilms formation potential on stainless steel 304, stainless steel 316, galvanized steel, copper, cPVC, glass, carbon steel, and cast iron in water and reclaimed water systems. Experiments were conducted using bioreactor containers, each bioreactor housed four sampling boxes with eight partitions, dedicated to each material type coupon. One bioreactor was stationed at ASU, and one at Vistancia Aquifer Storage and Recovery (ASR) well; while three bioreactors were stationed at Butler facility, at pre-disinfection, post-UV and post-chlorination. From each location, one submerged sampling box was retrieved after 1, 3, 6 and 12 months. Time series of biofilm samples recovered from various types of coupons from different locations were analyzed using physical and culture-based techniques for quantification of biofilms and detection of heterotrophic plate count (HPC) bacteria, Legionella, Mycobacterium, and sulfate reducing bacteria (SRB). After one-year, galvanized steel had the highest concentration of HPC at 4.27 logs while copper had the lowest concentration of 3.08 logs of HPC. Bacterial growth data collected from the SRB tests was compiled to develop a numerical matrix using growth potential, biofilm formation potential and metal reduction potential of SRB isolates. This risk assessment matrix can be a useful tool for the water industry to evaluate the potential risk of MIC in their systems.
ContributorsNeal, Amber (Author) / Abbaszadegan, Morteza (Thesis advisor) / Fox, Peter (Committee member) / Alum, Absar (Committee member) / Arizona State University (Publisher)
Created2022
161499-Thumbnail Image.png
Description
Nitrogen removal and energy reduction in wastewater treatment are shared goals. Approaches to achieve those goals include the techniques of shortcut nitrogen removal utilizing nitrite shunt, biocatalyst, nitritation, deammonification, and simultaneous nitrification-denitrification. The practice of those techniques is newer in the industry of wastewater treatment but continues to develop, along

Nitrogen removal and energy reduction in wastewater treatment are shared goals. Approaches to achieve those goals include the techniques of shortcut nitrogen removal utilizing nitrite shunt, biocatalyst, nitritation, deammonification, and simultaneous nitrification-denitrification. The practice of those techniques is newer in the industry of wastewater treatment but continues to develop, along with the understanding of the biological and chemical activities that drive those processes. The kinetics and stoichiometry of traditional and shortcut nitrogen removal reactions are generally well understood to date. However, the thermodynamics of those processes are complex and deserve additional research to better understand the dominant factors that drive cell synthesis. Additionally, the implementation of nitrogen shortcut techniques can reduce the footprint of wastewater treatment processes that implement nitrogen removal by approximately 5 percent and can reduce operating costs by between 12 and 26 percent annually. Combined, nitrogen shortcut techniques can contribute to significant reduction in the long-term cost to operate, due to lower energy and consumable requirements, fast reaction times resulting in shorter solids retention times, and improvement efficiency in nitrogen removal from wastewater. This dissertation explores and defines the dominant factors that contribute to the success of efficiencies in traditional and shortcut nitrogen removal techniques, focusing on the natural microbiological processes. The culmination of these efforts was used to develop decision matrices to promote consideration of nitrogen shortcut techniques by practitioners during conceptual planning and design of wastewater treatment facilities.
ContributorsTack, Frederick Henry (Author) / Fox, Peter (Thesis advisor) / Krajmalnik-Brown, Rosa (Committee member) / Abbaszadegan, Morteza (Committee member) / Alum, Absar (Committee member) / Arizona State University (Publisher)
Created2021