Matching Items (13)
Filtering by

Clear all filters

151772-Thumbnail Image.png
Description
Ingestion of high temperature mainstream gas into the rotor-stator cavities of a gas turbine is one of the major problems faced by the turbine designers. The ingested gas heats up rotor disks and induces higher thermal stresses on them, giving rise to durability concern. Ingestion is usually reduced by installing

Ingestion of high temperature mainstream gas into the rotor-stator cavities of a gas turbine is one of the major problems faced by the turbine designers. The ingested gas heats up rotor disks and induces higher thermal stresses on them, giving rise to durability concern. Ingestion is usually reduced by installing seals on the rotor and stator rims and by purging the disk cavity by secondary air bled from the compressor discharge. The geometry of the rim seals and the secondary air flow rate, together, influence the amount of gas that gets ingested into the cavities. Since the amount of secondary air bled off has a negative effect on the gas turbine thermal efficiency, one goal is to use the least possible amount of secondary air. This requires a good understanding of the flow and ingestion fields within a disk cavity. In the present study, the mainstream gas ingestion phenomenon has been experimentally studied in a model single-stage axial flow gas turbine. The turbine stage featured vanes and blades, and rim seals on both the rotor and stator. Additionally, the disk cavity contained a labyrinth seal radially inboard which effectively divided the cavity into a rim cavity and an inner cavity. Time-average static pressure measurements were obtained at various radial positions within the disk cavity, and in the mainstream gas path at three axial locations at the outer shroud spread circumferentially over two vane pitches. The time-average static pressure in the main gas path exhibited a periodic asymmetry following the vane pitch whose amplitude diminished with increasing distance from the vane trailing edge. The static pressure distribution increased with the secondary air flow rate within the inner cavity but was found to be almost independent of it in the rim cavity. Tracer gas (CO2) concentration measurements were conducted to determine the sealing effectiveness of the rim seals against main gas ingestion. For the rim cavity, the sealing effectiveness increased with the secondary air flow rate. Within the inner cavity however, this trend reversed -this may have been due to the presence of rotating low-pressure flow structures inboard of the labyrinth seal.
ContributorsThiagarajan, Jayanth kumar (Author) / Roy, Ramendra P (Thesis advisor) / Lee, Taewoo (Committee member) / Mignolet, Marc (Committee member) / Arizona State University (Publisher)
Created2013
151532-Thumbnail Image.png
Description
Modern day gas turbine designers face the problem of hot mainstream gas ingestion into rotor-stator disk cavities. To counter this ingestion, seals are installed on the rotor and stator disk rims and purge air, bled off from the compressor, is injected into the cavities. It is desirable to reduce the

Modern day gas turbine designers face the problem of hot mainstream gas ingestion into rotor-stator disk cavities. To counter this ingestion, seals are installed on the rotor and stator disk rims and purge air, bled off from the compressor, is injected into the cavities. It is desirable to reduce the supply of purge air as this decreases the net power output as well as efficiency of the gas turbine. Since the purge air influences the disk cavity flow field and effectively the amount of ingestion, the aim of this work was to study the cavity velocity field experimentally using Particle Image Velocimetry (PIV). Experiments were carried out in a model single-stage axial flow turbine set-up that featured blades as well as vanes, with purge air supplied at the hub of the rotor-stator disk cavity. Along with the rotor and stator rim seals, an inner labyrinth seal was provided which split the disk cavity into a rim cavity and an inner cavity. First, static gage pressure distribution was measured to ensure that nominally steady flow conditions had been achieved. The PIV experiments were then performed to map the velocity field on the radial-tangential plane within the rim cavity at four axial locations. Instantaneous velocity maps obtained by PIV were analyzed sector-by-sector to understand the rim cavity flow field. It was observed that the tangential velocity dominated the cavity flow at low purge air flow rate, its dominance decreasing with increase in the purge air flow rate. Radially inboard of the rim cavity, negative radial velocity near the stator surface and positive radial velocity near the rotor surface indicated the presence of a recirculation region in the cavity whose radial extent increased with increase in the purge air flow rate. Qualitative flow streamline patterns are plotted within the rim cavity for different experimental conditions by combining the PIV map information with ingestion measurements within the cavity as reported in Thiagarajan (2013).
ContributorsPathak, Parag (Author) / Roy, Ramendra P (Thesis advisor) / Calhoun, Ronald (Committee member) / Lee, Taewoo (Committee member) / Arizona State University (Publisher)
Created2013
153008-Thumbnail Image.png
Description
In order to achieve higher gas turbine efficiency, the main gas temperature at turbine inlet has been steadily increased from approximately 900°C to about 1500°C over the last few decades. This temperature is higher than the maximum acceptable temperature for turbine internals. The hot main gas may get ingested into

In order to achieve higher gas turbine efficiency, the main gas temperature at turbine inlet has been steadily increased from approximately 900°C to about 1500°C over the last few decades. This temperature is higher than the maximum acceptable temperature for turbine internals. The hot main gas may get ingested into the space between rotor and stator, the rotor-stator disk cavity in a stage because of the pressure differential between main gas annulus and the disk cavity. To reduce this ingestion, the disk cavity is equipped with a rim seal; additionally, secondary (purge) air is supplied to the cavity. Since the purge air is typically bled off the compressor discharge, this reducing the overall gas turbine efficiency, much research has been carried out to estimate the minimum purge flow necessary (cw,min) for complete sealing of disk cavities.

In this work, experiments have been performed in a subscale single-stage axial turbine featuring vanes, blades and an axially-overlapping radial-clearance seal at the disk cavity rim. The turbine stage is also equipped with a labyrinth seal radially inboard. The stage geometry and the experimental conditions were such that the ingestion into the disk cavity was driven by the pressure asymmetry in the main gas annulus. In the experiments, time-averaged static pressure was measured at several locations in the main annulus and in the disk cavity; the pressure differential between a location on the vane platform close to lip (this being the rim seal part on the stator) and a location in the 'seal region' in the cavity is considered to be the driving potential for both ingestion and egress. Time-averaged volumetric concentration of the tracer gas (CO2) in the purge air supplied was measured at multiple radial locations on the stator surface. The pressure and ingestion data were then used to calculate the ingestion and egress discharge coefficients for a range of purge flow rates, employing a simple orifice model of the rim seal. For the experiments performed, the egress discharge coefficient increased and the ingestion discharge coefficient decreased with the purge air flow rate. A method for estimation of cw,min is also proposed.
ContributorsSingh, Prashant (Author) / Roy, Ramendra P (Thesis advisor) / Mignolet, Marc (Thesis advisor) / Lee, Taewoo (Committee member) / Arizona State University (Publisher)
Created2014
153086-Thumbnail Image.png
Description
A municipal electric utility in Mesa, Arizona with a peak load of approximately 85 megawatts (MW) was analyzed to determine how the implementation of renewable resources (both wind and solar) would affect the overall cost of energy purchased by the utility. The utility currently purchases all of its energy

A municipal electric utility in Mesa, Arizona with a peak load of approximately 85 megawatts (MW) was analyzed to determine how the implementation of renewable resources (both wind and solar) would affect the overall cost of energy purchased by the utility. The utility currently purchases all of its energy through long term energy supply contracts and does not own any generation assets and so optimization was achieved by minimizing the overall cost of energy while adhering to specific constraints on how much energy the utility could purchase from the short term energy market. Scenarios were analyzed for a five percent and a ten percent penetration of renewable energy in the years 2015 and 2025. Demand Side Management measures (through thermal storage in the City's district cooling system, electric vehicles, and customers' air conditioning improvements) were evaluated to determine if they would mitigate some of the cost increases that resulted from the addition of renewable resources.

In the 2015 simulation, wind energy was less expensive than solar to integrate to the supply mix. When five percent of the utility's energy requirements in 2015 are met by wind, this caused a 3.59% increase in the overall cost of energy. When that five percent is met by solar in 2015, it is estimated to cause a 3.62% increase in the overall cost of energy. A mix of wind and solar in 2015 caused a lower increase in the overall cost of energy of 3.57%. At the ten percent implementation level in 2015, solar, wind, and a mix of solar and wind caused increases of 7.28%, 7.51% and 7.27% respectively in the overall cost of energy.

In 2025, at the five percent implementation level, wind and solar caused increases in the overall cost of energy of 3.07% and 2.22% respectively. In 2025, at the ten percent implementation level, wind and solar caused increases in the overall cost of energy of 6.23% and 4.67% respectively.

Demand Side Management reduced the overall cost of energy by approximately 0.6%, mitigating some of the cost increase from adding renewable resources.
ContributorsCadorin, Anthony (Author) / Phelan, Patrick (Thesis advisor) / Calhoun, Ronald (Committee member) / Trimble, Steve (Committee member) / Arizona State University (Publisher)
Created2014
153299-Thumbnail Image.png
Description
With a ground-based Doppler lidar on the upwind side of a wind farm in the Tehachapi Pass of California, radial wind velocity measurements were collected for repeating sector sweeps, scanning up to 10 kilometers away. This region consisted of complex terrain, with the scans made between mountains. The dataset was

With a ground-based Doppler lidar on the upwind side of a wind farm in the Tehachapi Pass of California, radial wind velocity measurements were collected for repeating sector sweeps, scanning up to 10 kilometers away. This region consisted of complex terrain, with the scans made between mountains. The dataset was utilized for techniques being studied for short-term forecasting of wind power by correlating changes in energy content and of turbulence intensity by tracking spatial variance, in the wind ahead of a wind farm. A ramp event was also captured and its propagation was tracked.

Orthogonal horizontal wind vectors were retrieved from the radial velocity using a sector Velocity Azimuth Display method. Streamlines were plotted to determine the potential sites for a correlation of upstream wind speed with wind speed at downstream locations near the wind farm. A "virtual wind turbine" was "placed" in locations along the streamline by using the time-series velocity data at the location as the input to a modeled wind turbine, to determine the extractable energy content at that location. The relationship between this time-dependent energy content upstream and near the wind farm was studied. By correlating the energy content with each upstream location based on a time shift estimated according to advection at the mean wind speed, several fits were evaluated. A prediction of the downstream energy content was produced by shifting the power output in time and applying the best-fit function. This method made predictions of the power near the wind farm several minutes in advance. Predictions were also made up to an hour in advance for a large ramp event. The Magnitude Absolute Error and Standard Deviation are presented for the predictions based on each selected upstream location.
ContributorsMagerman, Beth (Author) / Calhoun, Ronald (Thesis advisor) / Peet, Yulia (Committee member) / Huang, Huei-Ping (Committee member) / Krishnamurthy, Raghavendra (Committee member) / Arizona State University (Publisher)
Created2014
150392-Thumbnail Image.png
Description
In this thesis the performance of a Hybrid AC System (HACS) is modeled and optimized. The HACS utilizes solar photovoltaic (PV) panels to help reduce the demand from the utility during peak hours. The system also includes an ice Thermal Energy Storage (TES) tank to accumulate cooling energy during off-peak

In this thesis the performance of a Hybrid AC System (HACS) is modeled and optimized. The HACS utilizes solar photovoltaic (PV) panels to help reduce the demand from the utility during peak hours. The system also includes an ice Thermal Energy Storage (TES) tank to accumulate cooling energy during off-peak hours. The AC runs continuously on grid power during off-peak hours to generate cooling for the house and to store thermal energy in the TES. During peak hours, the AC runs on the power supplied from the PV, and cools the house along with the energy stored in the TES. A higher initial cost is expected due to the additional components of the HACS (PV and TES), but a lower operational cost due to higher energy efficiency, energy storage and renewable energy utilization. A house cooled by the HACS will require a smaller size AC unit (about 48% less in the rated capacity), compared to a conventional AC system. To compare the cost effectiveness of the HACS with a regular AC system, time-of-use (TOU) utility rates are considered, as well as the cost of the system components and the annual maintenance. The model shows that the HACS pays back its initial cost of $28k in about 6 years with an 8% APR, and saves about $45k in total cost when compared to a regular AC system that cools the same house for the same period of 6 years.
ContributorsJubran, Sadiq (Author) / Phelan, Patrick (Thesis advisor) / Calhoun, Ronald (Committee member) / Trimble, Steve (Committee member) / Arizona State University (Publisher)
Created2011
137102-Thumbnail Image.png
Description
The global energy demand is expected to grow significantly in the next several decades and support for energy generation with high carbon emissions is continuing to decline. Alternative methods have gained interest, and wind energy has established itself as a viable source. Standard wind farms have limited room for growth

The global energy demand is expected to grow significantly in the next several decades and support for energy generation with high carbon emissions is continuing to decline. Alternative methods have gained interest, and wind energy has established itself as a viable source. Standard wind farms have limited room for growth and improvement, so wind energy has started to explore different directions. The urban environment is a potential direction for wind energy due to its proximity to the bulk of energy demand. CFD analysis has demonstrated that the presence of buildings can accelerate wind speeds between buildings and on rooftops. However, buildings generate areas of increased turbulence at their surface. The turbulence thickness and intensity vary with roof shape, building height, and building orientation. The analysis has concluded that good wind resource is possible in the urban environment in specific locations. With that, turbine selection becomes very important. A comparison has concluded that vertical axis wind turbines are more useful in the urban environment than horizontal axis wind turbines. Furthermore, building-augmented wind turbines are recommended because they are architecturally integrated into a building for the specific purpose of generating more energy. The research has concluded that large-scale generation in the urban environment is unlikely to be successful, but small-scale generation is quite viable. Continued research and investigation on urban wind energy is recommended.
ContributorsKlumpers, Ryan Scott (Author) / Calhoun, Ronald (Thesis director) / Huang, Huei-Ping (Committee member) / Barrett, The Honors College (Contributor) / Mechanical and Aerospace Engineering Program (Contributor)
Created2014-05
149432-Thumbnail Image.png
Description
Efficient performance of gas turbines depends, among several parameters, on the mainstream gas entry temperature. At the same time, transport of this high temperature gas into the rotor-stator cavities of turbine stages affects the durability of rotor disks. This transport is usually countered by installing seals on the rotor and

Efficient performance of gas turbines depends, among several parameters, on the mainstream gas entry temperature. At the same time, transport of this high temperature gas into the rotor-stator cavities of turbine stages affects the durability of rotor disks. This transport is usually countered by installing seals on the rotor and stator disk rims and by pressurizing the cavities by injecting air (purge gas) bled from the compressor discharge. The configuration of the rim seals influences the magnitude of main gas ingestion as well as the interaction of the purge gas with the main gas. The latter has aerodynamic and hub endwall heat transfer implications in the main gas path. In the present work, experiments were performed on model single-stage and 1.5-stage axial-flow turbines. The turbines featured vanes, blades, and rim seals on both the rotor and stator disks. Three different rim seal geometries, viz., axially overlapping radial clearance rim seals for the single-stage turbine cavity and the 1.5-stage turbine aft cavity, and a rim seal with angular clearance for the single-stage turbine cavity were studied. In the single-stage turbine, an inner seal radially inboard in the cavity was also provided; this effectively divided the disk cavity into a rim cavity and an inner cavity. For the aft rotor-stator cavity of the 1.5-stage turbine, a labyrinth seal was provided radially inboard, again creating a rim cavity and an inner cavity. Measurement results of time-average main gas ingestion into the cavities using tracer gas (CO2), and ensemble-averaged trajectories of the purge gas flowing out through the rim seal gap into the main gas path using particle image velocimetry are presented. For both turbines, significant ingestion occurred only in the rim cavity. The inner cavity was almost completely sealed by the inner seal, at all purge gas flow rates for the single-stage turbine and at the higher purge gas flow rates for 1.5-stage turbine. Purge gas egress trajectory was found to depend on main gas and purge gas flow rates, the rim seal configuration, and the azimuthal location of the trajectory mapping plane with respect to the vanes.
ContributorsBalasubramanian, Jagdish Harihara (Author) / Roy, Ramendra P (Thesis advisor) / Lee, Taewoo (Committee member) / Phelan, Patrick (Committee member) / Arizona State University (Publisher)
Created2010
149421-Thumbnail Image.png
Description
Phase Change Material (PCM) plays an important role as a thermal energy storage device by utilizing its high storage density and latent heat property. One of the potential applications for PCM is in buildings by incorporating them in the envelope for energy conservation. During the summer season, the benefits are

Phase Change Material (PCM) plays an important role as a thermal energy storage device by utilizing its high storage density and latent heat property. One of the potential applications for PCM is in buildings by incorporating them in the envelope for energy conservation. During the summer season, the benefits are a decrease in overall energy consumption by the air conditioning unit and a time shift in peak load during the day. Experimental work was carried out by Arizona Public Service (APS) in collaboration with Phase Change Energy Solutions (PCES) Inc. with a new class of organic-based PCM. This "BioPCM" has non-flammable properties and can be safely used in buildings. The experimental setup showed maximum energy savings of about 30%, a maximum peak load shift of ~ 60 min, and maximum cost savings of about 30%. Simulation was performed to validate the experimental results. EnergyPlus was chosen as it has the capability to simulate phase change material in the building envelope. The building material properties were chosen from the ASHRAE Handbook - Fundamentals and the HVAC system used was a window-mounted heat pump. The weather file used in the simulation was customized for the year 2008 from the National Renewable Energy Laboratory (NREL) website. All EnergyPlus inputs were ensured to match closely with the experimental parameters. The simulation results yielded comparable trends with the experimental energy consumption values, however time shifts were not observed. Several other parametric studies like varying PCM thermal conductivity, temperature range, location, insulation R-value and combination of different PCMs were analyzed and results are presented. It was found that a PCM with a melting point from 23 to 27 °C led to maximum energy savings and greater peak load time shift duration, and is more suitable than other PCM temperature ranges for light weight building construction in Phoenix.
ContributorsMuruganantham, Karthik (Author) / Phelan, Patrick (Thesis advisor) / Reddy, Agami (Committee member) / Lee, Taewoo (Committee member) / Arizona State University (Publisher)
Created2010
149424-Thumbnail Image.png
Description
A major concern in the operation of present-day gas turbine engines is the ingestion of hot mainstream gas into rotor-stator disk cavities of the high-pressure turbine stages. Although the engines require high gas temperature at turbine entry for good performance efficiency, the ingested gas shortens the lives of the cavity

A major concern in the operation of present-day gas turbine engines is the ingestion of hot mainstream gas into rotor-stator disk cavities of the high-pressure turbine stages. Although the engines require high gas temperature at turbine entry for good performance efficiency, the ingested gas shortens the lives of the cavity internals, particularly that of the rotor disks. Steps such as installing seals at the disk rims and injecting purge (secondary) air bled from the compressor discharge into the cavities are implemented to reduce the gas ingestion. Although there are advantages to the above-mentioned steps, the performance of a gas turbine engine is diminished by the purge air bleed-off. This then requires that the cavity sealing function be achieved with as low a purge air supply rate as possible. This, in turn, renders imperative an in-depth understanding of the pressure and velocity fields in the main gas path and within the disk cavities. In this work, experiments were carried out in a model 1.5-stage (stator-rotor-stator) axial air turbine to study the ingestion of main air into the aft, rotor-stator, disk cavity. The cavity featured rotor and stator rim seals with radial clearance and axial overlap and an inner labyrinth seal. First, time-average static pressure distribution was measured in the main gas path upstream and downstream of the rotor as well as in the cavity to ensure that a nominally steady run condition had been achieved. Main gas ingestion was determined by measuring the concentration distribution of tracer gas (CO2) in the cavity. To map the cavity fluid velocity field, particle image velocimetry was employed. Results are reported for two main air flow rates, two rotor speeds, and four purge air flow rates.
ContributorsJunnarkar, Nihal (Author) / Roy, Ramendra P (Thesis advisor) / Mignolet, Marc (Committee member) / Lee, Taewoo (Committee member) / Arizona State University (Publisher)
Created2010