Matching Items (3)
Filtering by

Clear all filters

151097-Thumbnail Image.png
Description
Power generation in remote isolated places is a tough problem. Presently, a common source for remote generation is diesel. However, diesel generation is costly and environmental unfriendly. It is promising to replace the diesel generation with some clean and economical generation sources. The concept of renewable generation offers a solution

Power generation in remote isolated places is a tough problem. Presently, a common source for remote generation is diesel. However, diesel generation is costly and environmental unfriendly. It is promising to replace the diesel generation with some clean and economical generation sources. The concept of renewable generation offers a solution to remote generation. This thesis focuses on evaluation of renewable generation penetration in the remote isolated grid. A small town named Coober Pedy in South Australia is set as an example. The first task is to build the stochastic models of solar irradiation and wind speed based on the local historical data. With the stochastic models, generation fluctuations and generation planning are further discussed. Fluctuation analysis gives an evaluation of storage unit size and costs. Generation planning aims at finding the relationships between penetration level and costs under constraint of energy sufficiency. The results of this study provide the best penetration level that makes the minimum energy costs. In the case of Coober Pedy, cases of wind and photovoltaic penetrations are studied. The additional renewable sources and suspended diesel generation change the electricity costs. Results show that in remote isolated grid, compared to diesel generation, renewable generation can lower the energy costs.
ContributorsZhu, Yujia (Author) / Holbert, Keith E. (Thesis advisor) / Karady, George G. (Committee member) / Tylavsky, Daniel J (Committee member) / Arizona State University (Publisher)
Created2012
155959-Thumbnail Image.png
Description
Passive cooling techniques, specifically passive downdraft cooling (PDC), have proven to be a solution that can address issues associated with air conditioning (AC). Globally, over 100 buildings have integrated PDC in its different forms, most of which use direct evaporative cooling. Even though all surveyed buildings were energy efficient and

Passive cooling techniques, specifically passive downdraft cooling (PDC), have proven to be a solution that can address issues associated with air conditioning (AC). Globally, over 100 buildings have integrated PDC in its different forms, most of which use direct evaporative cooling. Even though all surveyed buildings were energy efficient and cost-effective and most surveyed buildings were thermally comfortable, application of PDC remains limited. This study aims to advance performance of the single stage passive downdraft evaporative cooling tower (PDECT), and expand its applicability beyond the hot dry conditions where it is typically used, by designing and testing a multi-stage passive and hybrid downdraft cooling tower (PHDCT). Experimental evaluation on half-scale prototypes of these towers was conducted in Tempe, Arizona, during the hot dry and hot humid days of Summer, 2017. Ambient air dry-bulb temperatures ranged between 73.0°F with 82.9 percent coincident relative humidity, and 123.4°F with 7.8 percent coincident relative humidity. Cooling systems in both towers were operated simultaneously to evaluate performance under identical conditions.



Results indicated that the hybrid tower outperformed the single stage tower under all ambient conditions and that towers site water consumption was at least 2 times lower than source water required by electric powered AC. Under hot dry conditions, the single stage tower produced average temperature drops of 35°F (5°F higher than what was reported in the literature), average air velocities of 200 fpm, and average cooling capacities of 4 tons. Furthermore, the hybrid tower produced average temperature drops of 45°F (50°F in certain operation modes), average air velocities of 160 fpm, and average cooling capacities exceeding 4 tons. Under hot humid conditions, temperature drops from the single stage tower were limited to the ambient air wet-bulb temperatures whereas drops continued beyond the wet-bulb in the hybrid tower, resulting in 60 percent decline in the former’s cooling capacity while maintaining the capacity of the latter. The outcomes from this study will act as an incentive for designers to consider incorporating PDC into their designs as a viable replacement/supplement to AC; thus, reducing the impact of the built environment on the natural environment.
ContributorsAl-Hassawi, Omar Dhia Sadulah (Author) / Bryan, Harvey (Thesis advisor) / Reddy, T Agami (Committee member) / Chalfoun, Nader (Committee member) / Arizona State University (Publisher)
Created2017
153072-Thumbnail Image.png
Description
The development of new policies favoring integration of renewable energy into the grid has created a need to relook at our existing infrastructure resources and at the way the power system is currently operated. Also, the needs of electric energy markets and transmission/generation expansion planning has created a niche for

The development of new policies favoring integration of renewable energy into the grid has created a need to relook at our existing infrastructure resources and at the way the power system is currently operated. Also, the needs of electric energy markets and transmission/generation expansion planning has created a niche for development of new computationally efficient and yet reliable, simple and robust power flow tools for such studies. The so called dc power flow algorithm is an important power flow tool currently in use. However, the accuracy and performance of dc power flow results is highly variable due to the various formulations which are in use. This has thus intensified the interest of researchers in coming up with better equivalent dc models that can closely match the performance of ac power flow solution.

This thesis involves the development of novel hot start dc model using a power transfer distribution factors (PTDFs) approach. This document also discusses the problems of ill-conditioning / rank deficiency encountered while deriving this model. This model is then compared to several dc power flow models using the IEEE 118-bus system and ERCOT interconnection both as the base case ac solution and during single-line outage contingency analysis. The proposed model matches the base case ac solution better than contemporary dc power flow models used in the industry.
ContributorsSood, Puneet (Author) / Tylavsky, Daniel J (Thesis advisor) / Vittal, Vijay (Committee member) / Ayyanar, Raja (Committee member) / Arizona State University (Publisher)
Created2014