Matching Items (3)
Filtering by

Clear all filters

152804-Thumbnail Image.png
Description
Arsenic (As) and chromium (Cr) occur naturally in AZ surface and groundwaters, pose different health impacts, and exhibit different treatment efficacies. Hexavalent chromium (Cr(VI)) has newly recognized human health concerns, and State and Federal agencies are evaluating a low Cr(VI)-specific maximum contaminant level (MCL) for drinking water. Occurrence of Cr

Arsenic (As) and chromium (Cr) occur naturally in AZ surface and groundwaters, pose different health impacts, and exhibit different treatment efficacies. Hexavalent chromium (Cr(VI)) has newly recognized human health concerns, and State and Federal agencies are evaluating a low Cr(VI)-specific maximum contaminant level (MCL) for drinking water. Occurrence of Cr and As in municipal drinking waters and industrial cooling tower waters was quantified by grab samples and compared with sampling results obtained from a new passive sampler developed specifically for Cr(VI). Cr(VI) and As concentrations in groundwater used for cooling tower make-up water concentrations were ~3 ppb and ~4 ppb, respectively, and were concentrated significantly in blowdown water (~20 ppb and ~40 ppb). Based upon pending Cr(VI), As, and other metal regulations, these blowdown waters will need routine monitoring and treatment. Cr(VI) concentrations in a water treatment plant (WTP) raw and finished water samples varied from 0.5 and 2 ppb for grab samples collected every 4 hours for 7 consecutive days using an ISCO sampler. The development of an ion exchange (IX) based passive sampler was validated in the field at the WTP and yielded an average exposure within 1 standard deviation of ISCO sampler grab data. Sampling at both the WTP and cooling towers suggested sources of Cr(III) from treatment chemicals or wood preservatives may exist. Since both facilities use chlorine oxidants, I quantified the apparent (pH=5) second-order rate constant for aqueous chlorine (HOCl/OCl-) with Cr(III) to form Cr(VI) as 0.7 M-1s-1. Under typical conditions (2 ppb Cr(III) ; 2 mg/L Cl2) the half-life for the conversion of Cr(III) to the more toxic form Cr(VI) is 4.7 hours. The occurrence studies in AZ and CA show the Cr(VI) and As treatment of groundwaters will be required to meet stringent Cr(VI) regulations. IX technologies, both strong base anion (SBA) and weak base anion (WBA) resin types were screened (and compared) for Cr removal. The SBA IX process for As removal was optimized by utilizing a reactive iron coagulation and filtration (RCF) process to treat spent IX brine, which was then reused to for SBA resin regeneration.
ContributorsBowen, Alexandra (Author) / Paul, Westerhoff K. (Thesis advisor) / Hristovski, Kiril (Committee member) / Halden, Rolf (Committee member) / Arizona State University (Publisher)
Created2014
156994-Thumbnail Image.png
Description
This dissertation critically evaluated methodologies and devices for assessing and protecting the health of human populations, with particular emphasis on groundwater remediation and the use of wastewater-based epidemiology (WBE) to inform population health. A meta-analysis and assessment of laboratory-scale treatability studies for removing chlorinated solvents from groundwater found that sediment

This dissertation critically evaluated methodologies and devices for assessing and protecting the health of human populations, with particular emphasis on groundwater remediation and the use of wastewater-based epidemiology (WBE) to inform population health. A meta-analysis and assessment of laboratory-scale treatability studies for removing chlorinated solvents from groundwater found that sediment microcosms operated as continuous-flow columns are preferable to batch bottles when seeking to emulate with high fidelity the complex conditions prevailing in the subsurface in contaminated aquifers (Chapter 2). Compared to monitoring at the field-scale, use of column microcosms also showed (i) improved chemical speciation, and (ii) qualitative predictability of field parameters (Chapter 3). Monitoring of glucocorticoid hormones in wastewater of a university campus showed (i) elevated stress levels particularly at the start of the semester, (ii) on weekdays relative to weekend days (p = 0.05) (161 ± 42 μg d-1 per person, 122 ± 54 μg d-1 per person; p ≤ 0.05), and (iii) a positive association between levels of stress hormones and nicotine (rs: 0.49) and caffeine (0.63) consumption in this student population (Chapter 4). Also, (i) alcohol consumption determined by WBE was in line with literature estimates for this young sub-population (11.3 ± 7.5 g d-1 per person vs. 10.1 ± 0.8 g d-1 per person), whereas caffeine and nicotine uses were below (114 ± 49 g d-1 per person, 178 ± 19 g d-1 per person; 627 ± 219 g d-1 per person, 927 ± 243 g d-1 per person). The introduction of a novel continuous in situ sampler to WBE brought noted benefits relative to traditional time-integrated sampling, including (i) a higher sample coverage (93% vs. 3%), (ii) an ability to captured short-term analyte pulses (e.g., heroin, fentanyl, norbuprenorphine, and methadone), and (iii) an overall higher mass capture for drugs of abuse like morphine, fentanyl, methamphetamine, amphetamine, and the opioid antagonist metabolite norbuprenorphine (p ≤ 0.01). Methods and devices developed in this work are poised to find applications in the remediation sector and in human health assessments.
ContributorsDriver, Erin Michelle (Author) / Halden, Rolf (Thesis advisor) / Conroy-Ben, Otakuye (Committee member) / Kavazanjian, Edward (Committee member) / Krajmalnik-Brown, Rosa (Committee member) / Arizona State University (Publisher)
Created2018
148171-Thumbnail Image.png
Description

As the return to normality in the wake of the COVID-19 pandemic enters its early stages, the necessity for accurate, quick, and community-wide surveillance of SARS-CoV-2 has been emphasized. Wastewater-based epidemiology (WBE) has been used across the world as a tool for monitoring the pandemic, but studies of its efficacy

As the return to normality in the wake of the COVID-19 pandemic enters its early stages, the necessity for accurate, quick, and community-wide surveillance of SARS-CoV-2 has been emphasized. Wastewater-based epidemiology (WBE) has been used across the world as a tool for monitoring the pandemic, but studies of its efficacy in comparison to the best-known method for surveillance, randomly selected COVID-19 testing, has limited research. This study evaluated the trends and correlations present between SARS-CoV-2 in the effluent wastewater of a large university campus and random COVID-19 testing results published by the university. A moderately strong positive correlation was found between the random testing and WBE surveillance methods (r = 0.63), and this correlation was strengthened when accommodating for lost samples during the experiment (r = 0.74).

ContributorsWright, Jillian (Author) / Halden, Rolf (Thesis director) / Driver, Erin (Committee member) / School of Music, Dance and Theatre (Contributor) / School of Life Sciences (Contributor) / Barrett, The Honors College (Contributor)
Created2021-05