153234-Thumbnail Image.png
Description
Granular activated carbon (GAC) filters are final polishing step in the drinking water treatment systems for removal of dissolved organic carbon fractions. Generally filters are colonized by bacterial communities and their activity reduces biodegradable solutes allowing partial regeneration of GAC's adsorptive capacity. When the bacteria pass into the filtrate due

Granular activated carbon (GAC) filters are final polishing step in the drinking water treatment systems for removal of dissolved organic carbon fractions. Generally filters are colonized by bacterial communities and their activity reduces biodegradable solutes allowing partial regeneration of GAC's adsorptive capacity. When the bacteria pass into the filtrate due to increased growth, microbiological quality of drinking water is compromised and regrowth in the distribution system occurs. Bacteria attached to carbon particles as biofilms or in conjugation with other bacteria were observed to be highly resistant to post filtration microbial mitigation techniques. Some of these bacteria were identified as pathogenic.

This study focuses on one such pathogen Legionella pneumophila which is resistant to environmental stressors and treatment conditions. It is also responsible for Legionnaires' disease outbreak through drinking water thus attracting attention of regulatory agencies. The work assessed the attachment and colonization of Legionella and heterotrophic bacteria in lab scale GAC media column filters. Quantification of Legionella and HPC in the influent, effluent, column's biofilms and on the GAC particles was performed over time using fluorescent microscopy and culture based techniques.

The results indicated gradual increase in the colonization of the GAC particles with HPC bacteria. Initially high number of Legionella cells were detected in the column effluent and were not detected on GAC suggesting low attachment of the cells to the particles potentially due to lack of any previous biofilms. With the initial colonization of the filter media by other bacteria the number of Legionella cells on the GAC particles and biofilms also increased. Presence of Legionella was confirmed in all the samples collected from the columns spiked with Legionella. Significant increase in the Legionella was observed in column's inner surface biofilm (0.25 logs up to 0.52 logs) and on GAC particles (0.42 logs up to 0.63 logs) after 2 months. Legionella and HPC attached to column's biofilm were higher than that on GAC particles indicating the strong association with biofilms. The bacterial concentration slowly increased in the effluent. This may be due to column's wall effect decreasing filter efficiency, possible exhaustion of GAC capacity over time and potential bacterial growth.
ContributorsSharma, Harsha (Author) / Abbaszadegan, Morteza (Thesis advisor) / Alum, Absar (Committee member) / Fox, Peter (Committee member) / Arizona State University (Publisher)
Created2014
153298-Thumbnail Image.png
Description
Research in microbial biofuels has dramatically increased over the last decade. The bulk of this research has focused on increasing the production yields of cyanobacteria and algal cells and improving extraction processes. However, there has been little to no research on the potential impact of viruses on the yields of

Research in microbial biofuels has dramatically increased over the last decade. The bulk of this research has focused on increasing the production yields of cyanobacteria and algal cells and improving extraction processes. However, there has been little to no research on the potential impact of viruses on the yields of these phototrophic microbes for biofuel production. Viruses have the potential to significantly reduce microbial populations and limit their growth rates. It is therefore important to understand how viruses affect phototrophic microbes and the prevalence of these viruses in the environment. For this study, phototrophic microbes were grown in glass bioreactors, under continuous light and aeration. Detection and quantification of viruses of both environmental and laboratory microbial strains were measured through the use of a plaque assay. Plates were incubated at 25º C under continuous direct florescent light. Several environmental samples were taken from Tempe Town Lake (Tempe, AZ) and all the samples tested positive for viruses. Virus free phototrophic microbes were obtained from plaque assay plates by using a sterile loop to scoop up a virus free portion of the microbial lawn and transferred into a new bioreactor. Isolated cells were confirmed virus free through subsequent plaque assays. Viruses were detected from the bench scale bioreactors of Cyanobacteria Synechocystis PCC 6803 and the environmental samples. Viruses were consistently present through subsequent passage in fresh cultures; demonstrating viral contamination can be a chronic problem. In addition TEM was performed to examine presence or viral attachment to cyanobacterial cells and to characterize viral particles morphology. Electron micrographs obtained confirmed viral attachment and that the viruses detected were all of a similar size and shape. Particle sizes were measured to be approximately 50-60 nm. Cell reduction was observed as a decrease in optical density, with a transition from a dark green to a yellow green color for the cultures. Phototrophic microbial viruses were demonstrated to persist in the natural environment and to cause a reduction in algal populations in the bioreactors. Therefore it is likely that viruses could have a significant impact on microbial biofuel production by limiting the yields of production ponds.
ContributorsKraft, Kyle (Author) / Abbaszadegan, Morteza (Thesis advisor) / Alum, Absar (Committee member) / Fox, Peter (Committee member) / Arizona State University (Publisher)
Created2014
153246-Thumbnail Image.png
Description
This study was devised to elucidate key information concerning the potential risk posed by Legionella in reclaimed water. A series of biological experiments and a recharge basin soil column study were conducted to examine the survival, growth, and transport of L. pneumophila through engineered reclaimed water systems. A pilot-scale, column

This study was devised to elucidate key information concerning the potential risk posed by Legionella in reclaimed water. A series of biological experiments and a recharge basin soil column study were conducted to examine the survival, growth, and transport of L. pneumophila through engineered reclaimed water systems. A pilot-scale, column study was set up to measure Legionella transport in the columns under Arizona recharge basin conditions. Two columns, A and B, were packed to a depth of 122 cm with a loamy sand media collected from a recharge basin in Mesa, Arizona. The grain size distribution of Column A differed from that of Column B by the removal of fines passing the #200 sieve. The different soil profiles represented by column A and B allowed for further investigation of soil attributes which influence the microbial transport mechanism. Both clear PVC columns stand at a height of 1.83 m with an inner diameter of 6.35 cm. Sampling ports were drilled into the column at the soil depths 15, 30, 60, 92, 122 cm. Both columns were acclimated with tertiary treated waste water and set to a flow rate of approximately 1.5 m/d. The columns were used to assess the transport of a bacterial indicator, E. coli, in addition to assessing the study's primary pathogen of concern, Legionella. Approximately, 〖10〗^7 to 〖10〗^9 E. coli cells or 〖10〗^6 to 〖10〗^7Legionella cells were spiked into the columns' head waters for each experiment. Periodically, samples were collected from each column's sampling ports, until a minimum of three pore volume passed through the columns.

The pilot-scale, column study produced novel results which demonstrated the mechanism for Legionella to be transported through recharge basin soil. E. coli was transported, through 122 cm of the media in under 6 hours, whereas, Legionella was transported, through the same distance, in under 30 hours. Legionella has been shown to survive in low nutrient conditions for over a year. Given the novel results of this proof of concept study, a claim can be made for the transport of Legionella into groundwater aquifers through engineering recharge basin conditions, in Central Arizona.
ContributorsMcBurnett, Lauren Rae (Author) / Abbaszadegan, Morteza (Thesis advisor) / Alum, Absar (Committee member) / Fox, Peter (Committee member) / Arizona State University (Publisher)
Created2014
150107-Thumbnail Image.png
Description
Titanium dioxide (TiO2) nanomaterial use is becoming more prevalent as is the likelihood of human exposure and environmental release. The goal of this thesis is to develop analytical techniques to quantify the level of TiO2 in complex matrices to support environmental, health, and safety research of TiO2 nanomaterials. A pharmacokinetic

Titanium dioxide (TiO2) nanomaterial use is becoming more prevalent as is the likelihood of human exposure and environmental release. The goal of this thesis is to develop analytical techniques to quantify the level of TiO2 in complex matrices to support environmental, health, and safety research of TiO2 nanomaterials. A pharmacokinetic model showed that the inhalation of TiO2 nanomaterials caused the highest amount to be absorbed and distributed throughout the body. Smaller nanomaterials (< 5nm) accumulated in the kidneys before clearance. Nanoparticles of 25 nm diameter accumulated in the liver and spleen and were cleared from the body slower than smaller nanomaterials. A digestion method using nitric acid, hydrofluoric acid, and hydrogen peroxide was found to digest organic materials and TiO2 with a recovery of >80%. The samples were measured by inductively coupled plasma-mass spectrometry (ICP-MS) and the method detection limit was 600 ng of Ti. An intratracheal instillation study of TiO2 nanomaterials in rats found anatase TiO2 nanoparticles in the caudal lung lobe of rats 1 day post instillation at a concentration of 1.2 ug/mg dry tissue, the highest deposition rate of any TiO2 nanomaterial. For all TiO2 nanomaterial morphologies the concentrations in the caudal lobes were significantly higher than those in the cranial lobes. In a study of TiO2 concentration in food products, white colored foods or foods with a hard outer shell had higher concentrations of TiO2. Hostess Powdered Donettes were found to have the highest Ti mass per serving with 200 mg Ti. As much as 3.8% of the total TiO2 mass was able to pass through a 0.45 um indicating that some of the TiO2 is likely nanosized. In a study of TiO2 concentrations in personal care products and paints, the concentration of TiO2 was as high as 117 ug/mg in Benjamin Moore white paint and 70 ug/mg in a Neutrogena sunscreen. Greater than 6% of Ti in one sunscreen was able to pass through a 0.45 um filter. The nanosized TiO2 in food products and personal care products may release as much as 16 mg of nanosized TiO2 per individual per day to wastewater.
ContributorsWeir, Alex Alan (Author) / Westerhoff, Paul K (Thesis advisor) / Hristovski, Kiril (Committee member) / Herckes, Pierre (Committee member) / Arizona State University (Publisher)
Created2011
150939-Thumbnail Image.png
Description
Bacteroides have been suggested as alternative indicators of fecal pollution since they are highly abundant in feces and are thought to have limited potential to grow in environment. However, recent literature suggests that Bacteroides can potentially survive within water distribution systems. The first objective of this study was therefore to

Bacteroides have been suggested as alternative indicators of fecal pollution since they are highly abundant in feces and are thought to have limited potential to grow in environment. However, recent literature suggests that Bacteroides can potentially survive within water distribution systems. The first objective of this study was therefore to investigate the validity of Bacteroides as a fecal indicator for drinking water through laboratory experiments and field studies. Experiments were performed using a laboratory scale PVC model water distribution system that was spiked with 109 Bacteroides. Samples were collected over the following four and analyzed by culture and molecular-based techniques. Second, field studies were performed by collecting water meters from two large chlorinated water distribution systems in central Arizona. Upon removal for repair by city personnel, meters were collected and biofilms samples were gathered within two hours. The biofilms were then analyzed using culture and molecular-based assays. The results from these studies support the hypothesis that Bacteroides DNA may be found in water distribution systems despite the difficulty of cultivating these bacterial cells. These experiments present the importance of considering biofilm interactions with fecal indicator bacteria when performing molecular assays on environmental samples, as biofilms may provide protection from high oxygen concentrations and grazing protozoa in bulk water that limit the persistence Bacteroides in the environment. Although the significance of biofilm interactions with surface or recreational waters may be small, they are likely important when considering drinking water delivered through distribution systems. The second objective of this study was to investigate alternative detection methodologies for the fecal indicator Bacteroides. In particular, this study focused on using a simplified protocol of Nucleic Acid Sequence Based Amplification (NASBA) and Thermophilic Helicase-Dependent Amplification (tHDA) to amplify the highly conserved 16s rRNA gene in the genomic DNA of fecal indicator Bacteroides. The results of this study show that the simplified NASBA procedure was not able to amplify the target, while continuous problems with tHDA exposed the methods lack of reliability. These results suggest higher reliability in the isothermal amplification methods needs to be achieved before application to environmental samples.
ContributorsDunkin, Nate (Author) / Abbaszadegan, Morteza (Thesis advisor) / Alum, Absar (Committee member) / Fox, Peter (Committee member) / Arizona State University (Publisher)
Created2012
154132-Thumbnail Image.png
Description
The purpose of this study was to determine the applicability of fluorescent microspheres as a surrogate to measure the removal of Cryptosporidium oocysts through the coagulation, flocculation, sedimentation, and filtration steps of conventional water treatment. In order to maintain accuracy and applicability, a local water treatment facility was chosen as

The purpose of this study was to determine the applicability of fluorescent microspheres as a surrogate to measure the removal of Cryptosporidium oocysts through the coagulation, flocculation, sedimentation, and filtration steps of conventional water treatment. In order to maintain accuracy and applicability, a local water treatment facility was chosen as the system to model. The city of Chandler Arizona utilizes conventional treatment methodologies to remove pathogens from municipal drinking water and thus the water, coagulant, polymer, and doses concentrations were sourced directly from the plant. Jar testing was performed on four combinations of coagulant, polymer, and fluorescent microsphere to determine if the log removal was similar to that of Cryptosporidium oocysts.

Complications with the material properties of the microspheres arose during testing that ultimately yielded unfavorable but conclusive results. Log removal of microspheres did not increase with added coagulant in the predicted manner, though the beads were seen aggregating, the low density of the particles made the sedimentation step inefficient. This result can be explained by the low density of the microspheres as well as the potential presence of residual coagulant present in the system. Given the unfavorable properties of the beads, they do not appear to be a suitable candidate for the surrogacy of Cryptosporidium oocysts in conventional drinking water treatment. The beads in their current state are not an adequate surrogate; however, future testing has been outlined to modify the experiment in such a way that the microspheres should behave like oocysts in terms of physical transportation.
ContributorsLinks, Alexander Glenn (Author) / Abbaszadegan, Morteza (Thesis advisor) / Alum, Absar (Committee member) / Fox, Peter (Committee member) / Arizona State University (Publisher)
Created2015
154188-Thumbnail Image.png
Description
Quagga Mussels (Dreissena bugensis) are an invasive species of mollusk that have established themselves within the Colorado River system of Arizona since 2007. However, despite close proximity and frequent travel by recreational boaters between reservoirs, they have not yet infested the Salt River or Verde River systems. Laboratory experimentation was

Quagga Mussels (Dreissena bugensis) are an invasive species of mollusk that have established themselves within the Colorado River system of Arizona since 2007. However, despite close proximity and frequent travel by recreational boaters between reservoirs, they have not yet infested the Salt River or Verde River systems. Laboratory experimentation was done to test the survival rate of adult D. bugensis specimens in waters collected from Bartlett Lake (Verde River), Saguaro Lake (Salt River), and Salt River Project (SRP) canals (Salt River/Verde River/Colorado River blend) as well as Central Arizona Project (CAP) canals with the addition of turbidity to simulate high runoff storm events. Under each condition, adult survival for a time period of 21 days exceeded 98%, ruling out water chemistry or turbidity as a factor. Spawning was investigated using mussels collected from Lake Pleasant in August 2015. In 4 trials of serotonin dosage between 0.5 – 1.0 mMol, spawning was not successful. Calanoid copepod predation was also investigated by field sampling at Lake Pleasant, Saguaro Lake, and Bartlett Lake during September 2015. Calanoid copepods were identified in Lake Pleasant at a density of 104.22 individuals per cubic meter at a depth of 2 meters and 9.75 individuals per cubic meter at the surface. Calanoid copepods were not found in Bartlett Lake or Saguaro Lake, ruling out copepod predation as a factor. Finally, dissolved oxygen and temperature trends were analyzed in each reservoir. While temperature profiles are similar throughout the year, seasonal drops in dissolved oxygen below survivable concentrations for D. bugensis has been observed in both Saguaro Lake and Bartlett Lake but not Lake Pleasant, representing the most plausible explanation for no observed infestation.
ContributorsSokolowski, Matthew (Author) / Fox, Peter (Thesis advisor) / Abbaszadegan, Morteza (Thesis advisor) / Alum, Absar (Committee member) / Arizona State University (Publisher)
Created2015
156062-Thumbnail Image.png
Description
Drinking water filtration using reverse osmosis (RO) membranes effectively removes salts and most other inorganic, organic, and microbial pollutants. RO technologies are utilized at both the municipal and residential scale. The formation of biofilms on RO membranes reduces water flux and increases energy consumption. The research conducted for this thesis

Drinking water filtration using reverse osmosis (RO) membranes effectively removes salts and most other inorganic, organic, and microbial pollutants. RO technologies are utilized at both the municipal and residential scale. The formation of biofilms on RO membranes reduces water flux and increases energy consumption. The research conducted for this thesis involves In-Situ coating of silver, a known biocide, on the surface of RO membranes. This research was adapted from a protocol developed for coating flat sheet membranes with silver nanoparticles, and scaled up into spiral-wound membranes that are commonly used at the residential scale in point-of-use (POU) filtration systems. Performance analyses of the silver-coated spiral-wound were conducted in a mobile drinking water treatment system fitted with two POU units for comparison. Five month-long analyses were performed, including a deployment of the mobile system. In addition to flux, salt rejection, and other water quality analyses, additional membrane characterization tests were conducted on pristine and silver-coated membranes.

For flat sheet membranes coated with silver, the surface charge remained negative and contact angle remained below 90. Scaling up to spiral-wound RO membrane configuration was successful, with an average silver-loading of 1.93 g-Ag/cm2. Results showed the flux of water through the membrane ranged from 8 to 13 liters/m2*hr. (LMH) operating at 25% recovery during long-term of operation. The flux was initially decreased due to the silver coating, but no statistically significant differences were observed after 14 days of operation (P < 0.05). The salt rejection was also not effected due to the silver coating (P < 0.05). While 98% of silver was released during long-term studies, the silver release from the spiral-wound membrane was consistently below the secondary MCL of 100 ppb established by the EPA, and was consistently below 5 ppb after two hours of operation. Microbial assays in the form of heterotrophic plate counts suggested there was no statistically significant difference in the prevention of biofouling formation due to the silver coating (P < 0.05). In addition to performance tests and membrane characterizations, a remote data acquisition system was configured to remotely monitor performance and water quality parameters in the mobile system.
ContributorsZimmerman, Sean (Author) / Westerhoff, Paul K (Thesis advisor) / Sinha, Shahnawaz (Committee member) / Perreault, Francois (Committee member) / Arizona State University (Publisher)
Created2017
156429-Thumbnail Image.png
Description
Legionella pneumophila is a waterborne pathogen that causes Legionnaires' disease, an infection which can lead to potentially fatal pneumonia. In a culture-based technique, Legionella is detected using buffered charcoal-yeast extract (BCYE) agar supplemented with L-cysteine, Iron salt and antibiotics. These supplements provide essential and complex nutrient requirements and help in

Legionella pneumophila is a waterborne pathogen that causes Legionnaires' disease, an infection which can lead to potentially fatal pneumonia. In a culture-based technique, Legionella is detected using buffered charcoal-yeast extract (BCYE) agar supplemented with L-cysteine, Iron salt and antibiotics. These supplements provide essential and complex nutrient requirements and help in the suppression of non-target bacteria in Legionella analysis. Legionella occurs naturally in freshwater environments and for their detection; a sample is plated on solid agar media and then incubated for several days. There are many challenges in the detection of Legionella in environmental waters and the built environments. A common challenge is that a variety of environmental bacteria can be presumptively identified as Legionella using the culture-based method. In addition, proper identification of Legionella requires long incubation period (3-9 days) while antibiotics used in BCYE agar have relatively short half-life time. In order to overcome some of the challenges, Legionella has been genetically modified to express reporter genes such Green Fluorescent Protein (GFP) that can facilitate its detection in process validation studies under controlled laboratory conditions. However, such studies had limited success due to the instability of genetically modified Legionella strains. The development of a genetically modified Legionella with a much rapid growth rate (1-2 days) in simulated environmental systems (tightly-controlled water distribution system) is achieved. The mutant Legionella is engineered by transforming with a specific plasmid encoding CymR, LacZ and TetR genes. The newly engineered Legionella can grow on conventional BCYE agar media without L-Cysteine, Iron salt and only require one antibiotic (Tetracycline) to suppress the growth of other microorganisms in media. To the best of our knowledge, this is the first report of L. pneumophila strain capable of growing without L-Cysteine. We believe that this discovery would not only facilitate the study of the fate and transport of this pathogen in environmental systems, but also further our understanding of the genetics and metabolic pathways of Legionella.
ContributorsAloraini, Saleh Ali A (Author) / Abbaszadegan, Morteza (Thesis advisor) / Fox, Peter (Committee member) / Alum, Absar (Committee member) / Arizona State University (Publisher)
Created2018
157339-Thumbnail Image.png
Description
Mineral weathering and industrial activities cause elevated concentration of hexavalent chromium (Cr(VI)) in groundwater, and this poses potential health concern (>10 ppb) to southwestern USA. The conversion of Cr(VI) to Cr(III) – a fairly soluble and non-toxic form at typical pH of groundwater is an effective method to control the

Mineral weathering and industrial activities cause elevated concentration of hexavalent chromium (Cr(VI)) in groundwater, and this poses potential health concern (>10 ppb) to southwestern USA. The conversion of Cr(VI) to Cr(III) – a fairly soluble and non-toxic form at typical pH of groundwater is an effective method to control the mobility and carcinogenic effects of Cr(VI). In-situ chemical reduction using SnCl2 was investigated to initiate this redox process using jar testing with buffered ultrapure water and native Arizona groundwater spiked with varying Cr(VI) concentrations. Cr(VI) transformation by SnCl2 is super rapid (<60 seconds) and depends upon the molar dosage of Sn(II) to Cr(VI). Cr(VI) removal improved significantly at higher pH while was independent on Cr(VI) initial concentration and dissolved oxygen (DO) level. Co-existing oxyanions (As and W) competed with Cr(VI) for SnCl2 oxidation and adsorption sites of formed precipitates, thus resulted in lower Cr(VI) removal in the challenge water. SnCl2 reagent grade and commercial grade behaved similarly when freshly prepared, but the reducing strength of the commercial product decreased by 50% over a week after exposing to atmosphere. Equilibrium modeling with Visual MINTEQ suggested redox potential < 400 mV to reach Cr(VI) treatment goal of 10 ppb. Kinetics of Cr(VI) reduction was simulated via the rate expression: r=-k[H+]-0.25[Sn2+]0.5[Cr2O72-]3 with k = 0.146 uM-2.25s-1, which correlated consistently with experimental data under different pH and SnCl2 doses. These results proved SnCl2 reductive treatment is a simple and highly effective method to treat Cr(VI) in groundwater.
ContributorsNguyen, Duong Thanh (Author) / Westerhoff, Paul K (Thesis advisor) / Delgado, Anca G (Committee member) / Sinha, Shahnawaz (Committee member) / Arizona State University (Publisher)