Matching Items (10)
Filtering by

Clear all filters

Description
An eco-industrial park (EIP) is an industrial ecosystem in which a group of co-located firms are involved in collective resource optimization with each other and with the local community through physical exchanges of energy, water, materials, byproducts and services - referenced in the industrial ecology literature as "industrial symbiosis". EIPs,

An eco-industrial park (EIP) is an industrial ecosystem in which a group of co-located firms are involved in collective resource optimization with each other and with the local community through physical exchanges of energy, water, materials, byproducts and services - referenced in the industrial ecology literature as "industrial symbiosis". EIPs, when compared with standard industrial resource sharing networks, prove to be of greater public advantage as they offer improved environmental and economic benefits, and higher operational efficiencies both upstream and downstream in their supply chain.

Although there have been many attempts to adapt EIP methodology to existing industrial sharing networks, most of them have failed for various factors: geographic restrictions by governmental organizations on use of technology, cost of technology, the inability of industries to effectively communicate their upstream and downstream resource usage, and to diminishing natural resources such as water, land and non-renewable energy (NRE) sources for energy production.

This paper presents a feasibility study conducted to evaluate the comparative environmental, economic, and geographic impacts arising from the use of renewable energy (RE) and NRE to power EIPs. Life Cycle Assessment (LCA) methodology, which is used in a variety of sectors to evaluate the environmental merits and demerits of different kinds of products and processes, was employed for comparison between these two energy production methods based on factors such as greenhouse gas emission, acidification potential, eutrophication potential, human toxicity potential, fresh water usage and land usage. To complement the environmental LCA analysis, levelized cost of electricity was used to evaluate the economic impact. This model was analyzed for two different geographic locations; United States and Europe, for 12 different energy production technologies.

The outcome of this study points out the environmental, economic and geographic superiority of one energy source over the other, including the total carbon dioxide equivalent emissions, which can then be related to the total number of carbon credits that can be earned or used to mitigate the overall carbon emission and move closer towards a net zero carbon footprint goal thus making the EIPs truly sustainable.
ContributorsGupta, Vaibhav (Author) / Calhoun, Ronald J (Thesis advisor) / Dooley, Kevin (Committee member) / Phelan, Patrick (Committee member) / Arizona State University (Publisher)
Created2014
150124-Thumbnail Image.png
Description
Sinaloa, a coastal state in the northwest of Mexico, is known for irrigated conventional agriculture, and is considered one of the greatest successes of the Green Revolution. With the neoliberal reforms of the 1990s, Sinaloa farmers shifted out of conventional wheat, soy, cotton, and other commodities and into white maize,

Sinaloa, a coastal state in the northwest of Mexico, is known for irrigated conventional agriculture, and is considered one of the greatest successes of the Green Revolution. With the neoliberal reforms of the 1990s, Sinaloa farmers shifted out of conventional wheat, soy, cotton, and other commodities and into white maize, a major food staple in Mexico that is traditionally produced by millions of small-scale farmers. Sinaloa is now a major contributor to the national food supply, producing 26% of total domestic white maize production. Research on Sinaloa's maize has focused on economic and agronomic components. Little attention, however, has been given to the environmental sustainability of Sinaloa's expansion in maize. With uniquely biodiverse coastal and terrestrial ecosystems that support economic activities such as fishing and tourism, the environmental consequences of agriculture in Sinaloa are important to monitor. Agricultural sustainability assessments have largely focused on alternative agricultural approaches, or espouse alternative philosophies that are biased against conventional production. Conventional agriculture, however, provides a significant portion of the world's calories. In addition, incentives such as federal subsidies and other institutions complicate transitions to alternative modes of production. To meet the agricultural sustainability goals of food production and environmental stewardship, we must put conventional agriculture on a more sustainable path. One step toward achieving this is structuring agricultural sustainability assessments around achievable goals that encourage continual adaptations toward sustainability. I attempted this in my thesis by assessing conventional maize production in Sinaloa at the regional/state scale using network analysis and incorporating stakeholder values through a multicriteria decision analysis approach. The analysis showed that the overall sustainability of Sinaloa maize production is far from an ideal state. I made recommendations on how to improve the sustainability of maize production, and how to better monitor the sustainability of agriculture in Sinaloa.
ContributorsBausch, Julia Christine (Author) / Eakin, Hallie (Thesis advisor) / Bojórquez-Tapia, Luis (Committee member) / Childers, Daniel L. (Committee member) / Arizona State University (Publisher)
Created2011
150422-Thumbnail Image.png
Description
Among the various end-use sectors, the commercial sector is expected to have the second-largest increase in total primary energy consump¬tion from 2009 to 2035 (5.8 quadrillion Btu) with a growth rate of 1.1% per year, it is the fastest growing end-use sectors. In order to make major gains in reducing

Among the various end-use sectors, the commercial sector is expected to have the second-largest increase in total primary energy consump¬tion from 2009 to 2035 (5.8 quadrillion Btu) with a growth rate of 1.1% per year, it is the fastest growing end-use sectors. In order to make major gains in reducing U.S. building energy use commercial sector buildings must be improved. Energy benchmarking of buildings gives the facility manager or the building owner a quick evaluation of energy use and the potential for energy savings. It is the process of comparing the energy performance of a building to standards and codes, to a set target performance or to a range of energy performance values of similar buildings in order to help assess opportunities for improvement. Commissioning of buildings is the process of ensuring that systems are designed, installed, functionally tested and capable of being operated and maintained according to the owner's operational needs. It is the first stage in the building upgrade process after it has been assessed using benchmarking tools. The staged approach accounts for the interactions among all the energy flows in a building and produces a systematic method for planning upgrades that increase energy savings. This research compares and analyzes selected benchmarking and retrocommissioning tools to validate their accuracy such that they could be used in the initial audit process of a building. The benchmarking study analyzes the Energy Use Intensities (EUIs) and Ratings assigned by Portfolio Manager and Oak Ridge National Laboratory (ORNL) Spreadsheets. The 90.1 Prototype models and Commercial Reference Building model for Large Office building type were used for this comparative analysis. A case-study building from the DOE - funded Energize Phoenix program was also benchmarked for its EUI and rating. The retrocommissioning study was conducted by modeling these prototype models and the case-study building in the Facility Energy Decision System (FEDS) tool to simulate their energy consumption and analyze the retrofits suggested by the tool. The results of the benchmarking study proved that a benchmarking tool could be used as a first step in the audit process, encouraging the building owner to conduct an energy audit and realize the energy savings potential. The retrocommissioning study established the validity of FEDS as an accurate tool to simulate a building for its energy performance using basic inputs and to accurately predict the energy savings achieved by the retrofits recommended on the basis of maximum LCC savings.
ContributorsAgnihotri, Shreya Prabodhkumar (Author) / Reddy, T Agami (Thesis advisor) / Bryan, Harvey (Committee member) / Phelan, Patrick (Committee member) / Arizona State University (Publisher)
Created2011
151110-Thumbnail Image.png
Description
Urban sustainability is a critical component of sustainable human societies. Urban riparian parks are used here as a case study seeking to understand the social-ecological relationships between the subjective evaluation of ecosystem services and the vision and management of one kind of green infrastructure. This study explored attitudes towards ecosystem

Urban sustainability is a critical component of sustainable human societies. Urban riparian parks are used here as a case study seeking to understand the social-ecological relationships between the subjective evaluation of ecosystem services and the vision and management of one kind of green infrastructure. This study explored attitudes towards ecosystem services, asking whether 1) the tripartite model is an effective framing to measure attitudes towards ecosystem services; 2) what the attitudes towards ecosystem services are and whether they differ between two types of park space; and 3) what the relationship is between management and the attitudinal assessment of ecosystem services by park users. A questionnaire was administered to 104 urban riparian park users in Phoenix, AZ evaluating their attitudes towards refugia, aesthetics, microclimate and stormwater regulation, and recreational and educational opportunities. The operationalization of the tripartite model was validated and found reliable, but may not be the whole story in determining attitudes towards ecosystem services. All components of attitude were positive, but attitudes were stronger in a habitat rehabilitation area with densely planted native species and low flows, than in a more classic park with mowed lawns and scattered vegetation, a mix of native and non-native species, and open water. Park users were more positive towards refugia, stormwater regulation, recreation, and educational opportunities in the habitat rehabilitation area. On the other hand, microclimate regulation and aesthetic qualities were valued similarly between the two parks. Most attitudes supported management goals, however park users valued stormwater regulation less than managers. Qualitative answers suggest that the quality of human interactions differ between the parks and park users consider both elements of society and the physical environment in their subjective evaluations. These findings reveal that park users highly value ecosystem services and that park design and management mediates social-ecological relationships, which should at least underlie the context of economic discussions of service value. This study supports the provision of ecosystem services through green infrastructure and suggests that an integration of park designs throughout urban areas could provide both necessary services as well as expand the platform for social-ecological interactions.
ContributorsWilson, Lea Ione (Author) / Childers, Daniel L. (Thesis advisor) / Larson, Kelli L. (Committee member) / Stromberg, Juliet (Committee member) / Arizona State University (Publisher)
Created2012
154129-Thumbnail Image.png
Description
Pavement surface temperature is calculated using a fundamental energy balance model developed previously. It can be studied using a one-dimensional mathematical model. The input to the model is changed, to study the effect of different properties of pavement on its diurnal surface temperatures. It is observed that the pavement surface

Pavement surface temperature is calculated using a fundamental energy balance model developed previously. It can be studied using a one-dimensional mathematical model. The input to the model is changed, to study the effect of different properties of pavement on its diurnal surface temperatures. It is observed that the pavement surface temperature has a microclimatic effect on the air temperature above it. A major increase in local air temperature is caused by heating of solid surfaces in that locality. A case study was done and correlations have been established to calculate the air temperature above a paved surface. Validation with in-situ pavement surface and air temperatures were made. Experimental measurement for the city of Phoenix shows the difference between the ambient air temperature of the city and the microclimatic air temperature above the pavement is approximately 10 degrees Fahrenheit. One mitigation strategy that has been explored is increasing the albedo of the paved surface. Although it will reduce the pavement surface temperature, leading to a reduction in air temperature close to the surface, the increased pavement albedo will also result in greater reflected solar radiation directed towards the building, thus increasing the building solar load. The first effect will imply a reduction in the building energy consumption, while the second effect will imply an increase in the building energy consumption. Simulation is done using the EnergyPlus tool, to find the microclimatic effect of pavement on the building energy performance. The results indicate the cooling energy savings of an office building for different types of pavements can be variable as much as 30%.
ContributorsSengupta, Shawli (Author) / Phelan, Patrick (Thesis advisor) / Kaloush, Kamil (Committee member) / Calhoun, Ronald (Committee member) / Arizona State University (Publisher)
Created2015
156208-Thumbnail Image.png
Description
In recent years, 40% of the total world energy consumption and greenhouse gas emissions is because of buildings. Out of that 60% of building energy consumption is due to HVAC systems. Under current trends these values will increase in coming years. So, it is important to identify passive cooling or

In recent years, 40% of the total world energy consumption and greenhouse gas emissions is because of buildings. Out of that 60% of building energy consumption is due to HVAC systems. Under current trends these values will increase in coming years. So, it is important to identify passive cooling or heating technologies to meet this need. The concept of thermal energy storage (TES), as noted by many authors, is a promising way to rectify indoor temperature fluctuations. Due to its high energy density and the use of latent energy, Phase Change Materials (PCMs) are an efficient choice to use as TES. A question that has not satisfactorily been addressed, however, is the optimum location of PCM. In other words, given a constant PCM mass, where is the best location for it in a building? This thesis addresses this question by positioning PCM to obtain maximum energy savings and peak time delay. This study is divided into three parts. The first part is to understand the thermal behavior of building surfaces, using EnergyPlus software. For analysis, a commercial prototype building model for a small office in Phoenix, provided by the U.S. Department of Energy, is applied and the weather location file for Phoenix, Arizona is also used. The second part is to justify the best location, which is obtained from EnergyPlus, using a transient grey box building model. For that we have developed a Resistance-Capacitance (RC) thermal network and studied the thermal profile of a building in Phoenix. The final part is to find the best location for PCMs in buildings using EnergyPlus software. In this part, the mass of PCM used in each location remains unchanged. This part also includes the impact of the PCM mass on the optimized location and how the peak shift varies. From the analysis, it is observed that the ceiling is the best location to install PCM for yielding the maximum reduction in HVAC energy consumption for a hot, arid climate like Phoenix.
ContributorsPrem Anand Jayaprabha, Jyothis Anand (Author) / Phelan, Patrick (Thesis advisor) / Wang, Robert (Committee member) / Parrish, Kristen (Committee member) / Arizona State University (Publisher)
Created2018
157262-Thumbnail Image.png
Description
Cities are increasingly using nature-based approaches to address urban sustainability challenges. These solutions leverage the ecological processes associated with existing or newly constructed Urban Ecological Infrastructure (UEI) to address issues through ecosystem services (e.g. stormwater retention or treatment). The growing use of UEI to address urban sustainability challenges can bring

Cities are increasingly using nature-based approaches to address urban sustainability challenges. These solutions leverage the ecological processes associated with existing or newly constructed Urban Ecological Infrastructure (UEI) to address issues through ecosystem services (e.g. stormwater retention or treatment). The growing use of UEI to address urban sustainability challenges can bring together teams of urban researchers and practitioners to co-produce UEI design, monitoring and maintenance. However, this co-production process received little attention in the literature, and has not been studied in the Phoenix Metro Area.

I examined several components of a co-produced design process and related project outcomes associated with a small-scale UEI project – bioswales installed at the Arizona State University (ASU) Orange Mall and Student Pavilion in Tempe, AZ. Specifically, I explored the social design process and ecohydrological and biogeochemical outcomes associated with development of an ecohydrological monitoring protocol for assessing post-construction landscape performance of this site. The monitoring protocol design process was documented using participant observation of collaborative project meetings, and semi-structured interviews with key researchers and practitioners. Throughout this process, I worked together with researchers and practitioners to co-produced a suite of ecohydrological metrics to monitor the performance of the bioswales (UEI) constructed at Orange Mall, with an emphasis on understanding stormwater dynamics. I then installed and operated monitoring equipment from Summer 2018 to Spring 2019 to generate data that can be used to assess system performance with respect to the co-identified performance metrics.

The co-production experience resulted in observable change in attitudes both at the individual and institutional level with regards to the integration and use of urban ecological research to assess and improve UEI design. My ecological monitoring demonstrated that system performance met design goals with regards to stormwater capture, and water quality data suggest the system’s current design has some capacity for stormwater treatment. These data and results are being used by practitioners at ASU and their related design partners to inform future design and management of UEI across the ASU campus. More broadly, this research will provide insights into improving the monitoring, evaluation, and performance efficacy associated with collaborative stormwater UEI projects, independent of scale, in arid cities.
ContributorsSanchez, Christopher A (Author) / Childers, Daniel L. (Thesis advisor) / Cheng, Chingwen (Committee member) / York, Abigail M (Committee member) / Arizona State University (Publisher)
Created2019
154923-Thumbnail Image.png
Description
The aboveground surfaces of plants (i.e. the phyllosphere) comprise the largest biological interface on Earth (over 108 km2). The phyllosphere is a diverse microbial environment where bacterial inhabitants have been shown to sequester and degrade airborne pollutants (i.e. phylloremediation). However, phyllosphere dynamics are not well understood in urban environments,

The aboveground surfaces of plants (i.e. the phyllosphere) comprise the largest biological interface on Earth (over 108 km2). The phyllosphere is a diverse microbial environment where bacterial inhabitants have been shown to sequester and degrade airborne pollutants (i.e. phylloremediation). However, phyllosphere dynamics are not well understood in urban environments, and this environment has never been studied in the City of Phoenix, which maintains roughly 92,000 city trees. The phyllosphere will grow if the City of Phoenix is able to achieve its goal of 25% canopy coverage by 2030, but this begs the question: How and where should the urban canopy expand? I addressed this question from a phyllosphere perspective by sampling city trees of two species, Ulmus parvifolia (Chinese Elm) and Dalbergia sissoo (Indian Rosewood) in parks and on roadsides. I identified characteristics of the bacterial community structure and interpreted the ecosystem service potential of trees in these two settings. I used culture-independent methods to compare the abundance of each unique bacterial lineage (i.e. ontological taxonomic units or OTUs) on the leaves of park trees versus on roadside tree leaves. I found numerous bacteria (81 OTUs) that were significantly more abundant on park trees than on roadside trees. Many of these OTUs are ubiquitous to bacterial phyllosphere communities, are known to promote the health of the host tree, or have been shown to degrade airborne pollutants. Roadside trees had fewer bacteria (10 OTUs) that were significantly more abundant when compared to park trees, but several have been linked to the remediation of petroleum combustion by-products. These findings, that were not available prior to this study, may inform the City of Phoenix as it is designing its future urban forests.
ContributorsMacNeille, Benjamin C (Author) / Childers, Daniel L. (Thesis advisor) / Garcia-Pichel, Ferran (Committee member) / Cease, Arianne J (Committee member) / Arizona State University (Publisher)
Created2016
157528-Thumbnail Image.png
Description
Demand for green energy alternatives to provide stable and reliable energy

solutions has increased over the years which has led to the rapid expansion of global

markets in renewable energy sources such as solar photovoltaic (PV) technology. Newest

amongst these technologies is the Bifacial PV modules, which harvests incident radiation

from both sides of

Demand for green energy alternatives to provide stable and reliable energy

solutions has increased over the years which has led to the rapid expansion of global

markets in renewable energy sources such as solar photovoltaic (PV) technology. Newest

amongst these technologies is the Bifacial PV modules, which harvests incident radiation

from both sides of the module. The overall power generation can be significantly increased

by using these bifacial modules. The purpose of this research is to investigate and maximize

the effect of back reflectors, designed to increase the efficiency of the module by utilizing

the intercell light passing through the module to increase the incident irradiance, on the

energy output using different profiles placed at varied distances from the plane of the array

(POA). The optimum reflector profile and displacement of the reflector from the module

are determined experimentally.

Theoretically, a 60-cell bifacial module can produce 26% additional energy in

comparison to a 48-cell bifacial module due to the 12 excess cells found in the 60-cell

module. It was determined that bifacial modules have the capacity to produce additional

energy when optimized back reflectors are utilized. The inverted U reflector produced

higher energy gain when placed at farther distances from the module, indicating direct

dependent proportionality between the placement distance of the reflector from the module

and the output energy gain. It performed the best out of all current construction geometries

with reflective coatings, generating more than half of the additional energy produced by a

densely-spaced 60-cell benchmark module compared to a sparsely-spaced 48-cell reference

module.ii

A gain of 11 and 14% was recorded on cloudy and sunny days respectively for the

inverted U reflector. This implies a reduction in the additional cells of the 60-cell module

by 50% can produce the same amount of energy of the 60-cell module by a 48-cell module

with an inverted U reflector. The use of the back reflectors does not only affect the

additional energy gain but structural and land costs. Row to row spacing for bifacial

systems(arrays) is reduced nearly by half as the ground height clearance is largely

minimized, thus almost 50% of height constraints for mounting bifacial modules, using

back reflectors resulting in reduced structural costs for mounting of bifacial modules
ContributorsMARTIN, PEDRO JESSE (Author) / Tamizhmani, Govindasamy (Thesis advisor) / Phelan, Patrick (Committee member) / Wang, Liping (Committee member) / Arizona State University (Publisher)
Created2019
161465-Thumbnail Image.png
Description
The phase change process of freezing water is an important application in several fields such as ice making, food freezing technologies, pharmaceuticals etc. Due to the widespread usage of ice-related products, process improvements in this technology can potentially lead to substantial energy savings. After studying the freezing process of water,

The phase change process of freezing water is an important application in several fields such as ice making, food freezing technologies, pharmaceuticals etc. Due to the widespread usage of ice-related products, process improvements in this technology can potentially lead to substantial energy savings. After studying the freezing process of water, the supercooling phenomenon was found to occur which showed a negative effect. Therefore, ultrasound was proposed as a technique to reduce the supercooling effect and improve the heat transfer rate. An experimental study was conducted to analyze the energy expenditures in the freezing process with and without the application of ultrasound. After a set of preliminary experiments, an intermittent application of ultrasound at 10W & 3.5W power levels were found to be more effective than constant-power application, and were explored in further detail. The supercooling phenomenon was thoroughly studied through iterative experiments. It was also found that the application of ultrasound during the freezing process led to the formation of shard-like ice crystals. From the intermittent ultrasound experiments performed at 10W and 3.5W power levels, percentage energy enhancements relative to no ultrasound of 8.9% ± 12.4% and 11.9% ± 24.6% were observed, respectively.
ContributorsSubramanian, Varun (Author) / Phelan, Patrick (Thesis advisor) / Calhoun, Ronald (Committee member) / Rykaczewski, Konrad (Committee member) / Arizona State University (Publisher)
Created2021