Matching Items (3)
Filtering by

Clear all filters

152760-Thumbnail Image.png
Description
The need for alternative energy efficient building heating and cooling technologies has given rise to the development and widespread use of Ground Coupled Heat Pump (GCHP) systems. This dissertation looks at the feasibility of using GCHP systems as a viable economic alternative to traditional air source cooling systems (ASHP) for

The need for alternative energy efficient building heating and cooling technologies has given rise to the development and widespread use of Ground Coupled Heat Pump (GCHP) systems. This dissertation looks at the feasibility of using GCHP systems as a viable economic alternative to traditional air source cooling systems (ASHP) for conditioning buildings in the hot, semi-arid climate of Phoenix, Arizona. Despite high initial costs, GCHPs are gaining a foothold in northern climates where heating dominates, in large part due to government incentives. However, due to issues associated with low ground heat exchanger (GHE) efficiency and thermally-induced soil deformations, GCHPs are typically not considered a viable option in hot climates with deep groundwater and low permeability soil. To evaluate the energy performance and technical feasibility of GCHPs in Phoenix, the DOE 5,500 sq.ft small office, commercial building prototype was simulated in EnergyPlus to determine the cooling and heating loads. Next, a commercial software program, Ground Loop Design (GLD), was used to design and simulate the annual energy performance of both vertical (V-GCHPs) and horizontal GCHPs (H-GCHPs). Life cycle costs (LCC) were evaluated using realistic market costs both under dry, as well as fully saturated soil conditions (meant as an upper performance limit achievable by ground modification techniques). This analysis included performing several sensitivity analyses and also investigating the effect of financial rebates. The range of annual energy savings from the GCHP system for space cooling and heating was around 38-40% compared to ASHPs for dry soil. Saturated soil condition significantly affects the length of the GHE. For V-GCHPs, there was about 26% decrease in the length of GHE, thereby reducing the initial cost by 18-19% and decreasing the payback period by 24-25%. Likewise, for H-GCHPs, the length of GHE was reduced by 25% resulting in 22% and 39-42 % reduction in the initial cost and payback period respectively. With federal incentives, H-GCHPs under saturated soil conditions have the least LCC and a good payback periods of 2.3-4.7 years. V-GCHPs systems were been found to have payback periods of over 25 years, making them unfeasible for Phoenix, AZ, for the type of building investigated.
ContributorsTambe, Vaibhavi Parmanand (Author) / Reddy, T Agami (Thesis advisor) / Kavanzanjian, Edward (Thesis advisor) / Bryan, Harvey (Committee member) / Arizona State University (Publisher)
Created2014
150422-Thumbnail Image.png
Description
Among the various end-use sectors, the commercial sector is expected to have the second-largest increase in total primary energy consump¬tion from 2009 to 2035 (5.8 quadrillion Btu) with a growth rate of 1.1% per year, it is the fastest growing end-use sectors. In order to make major gains in reducing

Among the various end-use sectors, the commercial sector is expected to have the second-largest increase in total primary energy consump¬tion from 2009 to 2035 (5.8 quadrillion Btu) with a growth rate of 1.1% per year, it is the fastest growing end-use sectors. In order to make major gains in reducing U.S. building energy use commercial sector buildings must be improved. Energy benchmarking of buildings gives the facility manager or the building owner a quick evaluation of energy use and the potential for energy savings. It is the process of comparing the energy performance of a building to standards and codes, to a set target performance or to a range of energy performance values of similar buildings in order to help assess opportunities for improvement. Commissioning of buildings is the process of ensuring that systems are designed, installed, functionally tested and capable of being operated and maintained according to the owner's operational needs. It is the first stage in the building upgrade process after it has been assessed using benchmarking tools. The staged approach accounts for the interactions among all the energy flows in a building and produces a systematic method for planning upgrades that increase energy savings. This research compares and analyzes selected benchmarking and retrocommissioning tools to validate their accuracy such that they could be used in the initial audit process of a building. The benchmarking study analyzes the Energy Use Intensities (EUIs) and Ratings assigned by Portfolio Manager and Oak Ridge National Laboratory (ORNL) Spreadsheets. The 90.1 Prototype models and Commercial Reference Building model for Large Office building type were used for this comparative analysis. A case-study building from the DOE - funded Energize Phoenix program was also benchmarked for its EUI and rating. The retrocommissioning study was conducted by modeling these prototype models and the case-study building in the Facility Energy Decision System (FEDS) tool to simulate their energy consumption and analyze the retrofits suggested by the tool. The results of the benchmarking study proved that a benchmarking tool could be used as a first step in the audit process, encouraging the building owner to conduct an energy audit and realize the energy savings potential. The retrocommissioning study established the validity of FEDS as an accurate tool to simulate a building for its energy performance using basic inputs and to accurately predict the energy savings achieved by the retrofits recommended on the basis of maximum LCC savings.
ContributorsAgnihotri, Shreya Prabodhkumar (Author) / Reddy, T Agami (Thesis advisor) / Bryan, Harvey (Committee member) / Phelan, Patrick (Committee member) / Arizona State University (Publisher)
Created2011
155959-Thumbnail Image.png
Description
Passive cooling techniques, specifically passive downdraft cooling (PDC), have proven to be a solution that can address issues associated with air conditioning (AC). Globally, over 100 buildings have integrated PDC in its different forms, most of which use direct evaporative cooling. Even though all surveyed buildings were energy efficient and

Passive cooling techniques, specifically passive downdraft cooling (PDC), have proven to be a solution that can address issues associated with air conditioning (AC). Globally, over 100 buildings have integrated PDC in its different forms, most of which use direct evaporative cooling. Even though all surveyed buildings were energy efficient and cost-effective and most surveyed buildings were thermally comfortable, application of PDC remains limited. This study aims to advance performance of the single stage passive downdraft evaporative cooling tower (PDECT), and expand its applicability beyond the hot dry conditions where it is typically used, by designing and testing a multi-stage passive and hybrid downdraft cooling tower (PHDCT). Experimental evaluation on half-scale prototypes of these towers was conducted in Tempe, Arizona, during the hot dry and hot humid days of Summer, 2017. Ambient air dry-bulb temperatures ranged between 73.0°F with 82.9 percent coincident relative humidity, and 123.4°F with 7.8 percent coincident relative humidity. Cooling systems in both towers were operated simultaneously to evaluate performance under identical conditions.



Results indicated that the hybrid tower outperformed the single stage tower under all ambient conditions and that towers site water consumption was at least 2 times lower than source water required by electric powered AC. Under hot dry conditions, the single stage tower produced average temperature drops of 35°F (5°F higher than what was reported in the literature), average air velocities of 200 fpm, and average cooling capacities of 4 tons. Furthermore, the hybrid tower produced average temperature drops of 45°F (50°F in certain operation modes), average air velocities of 160 fpm, and average cooling capacities exceeding 4 tons. Under hot humid conditions, temperature drops from the single stage tower were limited to the ambient air wet-bulb temperatures whereas drops continued beyond the wet-bulb in the hybrid tower, resulting in 60 percent decline in the former’s cooling capacity while maintaining the capacity of the latter. The outcomes from this study will act as an incentive for designers to consider incorporating PDC into their designs as a viable replacement/supplement to AC; thus, reducing the impact of the built environment on the natural environment.
ContributorsAl-Hassawi, Omar Dhia Sadulah (Author) / Bryan, Harvey (Thesis advisor) / Reddy, T Agami (Committee member) / Chalfoun, Nader (Committee member) / Arizona State University (Publisher)
Created2017