Filtering by
- All Subjects: Air conditioning
- Creators: Chalfoun, Nader
- Creators: Fraser, Andrew
Results indicated that the hybrid tower outperformed the single stage tower under all ambient conditions and that towers site water consumption was at least 2 times lower than source water required by electric powered AC. Under hot dry conditions, the single stage tower produced average temperature drops of 35°F (5°F higher than what was reported in the literature), average air velocities of 200 fpm, and average cooling capacities of 4 tons. Furthermore, the hybrid tower produced average temperature drops of 45°F (50°F in certain operation modes), average air velocities of 160 fpm, and average cooling capacities exceeding 4 tons. Under hot humid conditions, temperature drops from the single stage tower were limited to the ambient air wet-bulb temperatures whereas drops continued beyond the wet-bulb in the hybrid tower, resulting in 60 percent decline in the former’s cooling capacity while maintaining the capacity of the latter. The outcomes from this study will act as an incentive for designers to consider incorporating PDC into their designs as a viable replacement/supplement to AC; thus, reducing the impact of the built environment on the natural environment.
Access to air conditioned space is critical for protecting urban populations from the adverse effects of heat exposure. Yet there remains fairly limited knowledge of penetration of private (home air conditioning) and distribution of public (cooling centers and commercial space) cooled space across cities. Furthermore, the deployment of government-sponsored cooling centers is not based on the location of existing cooling resources (residential air conditioning and air conditioned public space), raising questions of the equitability of access to heat refuges.
Using Los Angeles County, California and Maricopa County, Arizona (whose county seat is Phoenix) we explore the distribution of private and public cooling resources and access inequities at the household level. We do this by evaluating the presence of in-home air conditioning and developing a walking-based accessibility measure to air conditioned public space using a combined cumulative opportunities-gravity approach. We find significant inequities in the distribution of residential air conditioning across both regions which are largely attributable to building age and inter/intra-regional climate differences. There are also regional disparities in walkable access to public cooled space.
At average walking speeds, we find that official cooling centers are only accessible to a small fraction of households (3% in Los Angeles, 2% in Maricopa) while a significantly higher number of households (80% in Los Angeles, 39% in Maricopa) have access to at least one other type of public cooling resource which includes libraries and commercial establishments. Aggregated to a neighborhood level, we find that there are areas within each region where access to cooled space (either public or private) is limited which may increase the health risks associated with heat.