Description
Air conditioning is a significant energy consumer in buildings, especially in humid regions where a substantial portion of energy is used to remove moisture rather than cool the air. Traditional dehumidification methods, which cool air to its dew point to condense water vapor, are energy intensive. This process unnecessarily overcools

Air conditioning is a significant energy consumer in buildings, especially in humid regions where a substantial portion of energy is used to remove moisture rather than cool the air. Traditional dehumidification methods, which cool air to its dew point to condense water vapor, are energy intensive. This process unnecessarily overcools the air, only to reheat it to the desired temperature.This research introduces thermoresponsive materials as efficient desiccants to reduce energy demand for dehumidification. A system using lower critical solution temperature (LCST) type ionic liquids (ILs) as dehumidifiers is presented. Through the Flory-Huggins theory of mixtures, interactions between ionic liquids and water are analyzed. LCST ionic liquids demonstrate superior performance, with a coefficient of performance (COP) four times higher than non-thermoresponsive desiccants under similar conditions. The efficacy of ionic liquids as dehumidifiers is assessed based on properties like LCST temperature and enthalpic interaction parameter. The research also delves into thermoresponsive solid desiccants, particularly polymers, using the Vrentas-Vrentas model. This model offers a more accurate depiction of their behaviors compared to the Flory-Huggins theory by considering elastic energy stored in the polymers. Moisture absorption in thin film polymers is studied under diverse conditions, producing absorption isotherms for various temperatures and humidities. Using temperature-dependent interaction parameters, the behavior of the widely-used thermoresponsive polymer (TRP) PNIPAAm and hypothetical TRPs is investigated. The parameters from the model are used as input to do a finite element analysis of a thermoresponsive dehumidifier. This model demonstrates the complete absorption-desorption cycle under varied conditions such as polymer absorption temperature, relative humidity, and air speed. Results indicate that a TRP with enhanced absorption capacity and an LCST of 50℃ achieves a peak moisture removal efficiency (MRE) of 0.9 at 75% relative humidity which is comparable to other existing thermoresponsive dehumidification systems. But other TRPs with even greater absorption capacity can produce MRE as high as 3.6. This system also uniquely recovers water in liquid form.
ContributorsRana, Ashish (Author) / Wang, Robert RW (Thesis advisor) / Green, Matthew MG (Committee member) / Milcarek, Ryan RM (Committee member) / Wang, Liping LW (Committee member) / Phelan, Patrick PP (Committee member) / Arizona State University (Publisher)
Created2023
103-Thumbnail Image.png
Description

Access to air conditioned space is critical for protecting urban populations from the adverse effects of heat exposure. Yet there remains fairly limited knowledge of penetration of private (home air conditioning) and distribution of public (cooling centers and commercial space) cooled space across cities. Furthermore, the deployment of government-sponsored cooling

Access to air conditioned space is critical for protecting urban populations from the adverse effects of heat exposure. Yet there remains fairly limited knowledge of penetration of private (home air conditioning) and distribution of public (cooling centers and commercial space) cooled space across cities. Furthermore, the deployment of government-sponsored cooling centers is not based on the location of existing cooling resources (residential air conditioning and air conditioned public space), raising questions of the equitability of access to heat refuges.

Using Los Angeles County, California and Maricopa County, Arizona (whose county seat is Phoenix) we explore the distribution of private and public cooling resources and access inequities at the household level. We do this by evaluating the presence of in-home air conditioning and developing a walking-based accessibility measure to air conditioned public space using a combined cumulative opportunities-gravity approach. We find significant inequities in the distribution of residential air conditioning across both regions which are largely attributable to building age and inter/intra-regional climate differences. There are also regional disparities in walkable access to public cooled space.

At average walking speeds, we find that official cooling centers are only accessible to a small fraction of households (3% in Los Angeles, 2% in Maricopa) while a significantly higher number of households (80% in Los Angeles, 39% in Maricopa) have access to at least one other type of public cooling resource which includes libraries and commercial establishments. Aggregated to a neighborhood level, we find that there are areas within each region where access to cooled space (either public or private) is limited which may increase the health risks associated with heat.

Created2016