The building sector is responsible for consuming the largest proportional share of global material and energy resources. Some observers assert that buildings are the problem and the solution to climate change. It appears that in the United States a coherent national energy policy to encourage rapid building performance improvements is

The building sector is responsible for consuming the largest proportional share of global material and energy resources. Some observers assert that buildings are the problem and the solution to climate change. It appears that in the United States a coherent national energy policy to encourage rapid building performance improvements is not imminent. In this environment, where many climate and ecological scientists believe we are running out of time to reverse the effects of anthropogenic climate change, a local grass-roots effort to create demonstration net zero-energy buildings (ZEB) appears necessary. This paper documents the process of designing a ZEB in a community with no existing documented ZEB precedent. The project will establish a framework for collecting design, performance, and financial data for use by architects, building scientists, and the community at large. This type of information may prove critical in order to foster a near-term local demand for net zero-energy buildings.
ContributorsFrancis, Alan Merrill (Author) / Bryan, Harvey (Thesis advisor) / Addison, Marlin (Committee member) / Ramalingam, Muthukumar (Committee member) / Arizona State University (Publisher)
Created2014
152680-Thumbnail Image.png
Description
Rapid urbanization in Phoenix, Arizona has increased the nighttime temperature by 5°C (9 °F), and the average daily temperatures by 3.1°C (5.6 °F) (Baker et al 2002). On the macro scale, the energy balance of urban surface paving materials is the main contributor to the phenomenon of the Urban Heat

Rapid urbanization in Phoenix, Arizona has increased the nighttime temperature by 5°C (9 °F), and the average daily temperatures by 3.1°C (5.6 °F) (Baker et al 2002). On the macro scale, the energy balance of urban surface paving materials is the main contributor to the phenomenon of the Urban Heat Island effect (UHI). On the micro scale, it results in a negative effect on the pedestrian thermal comfort environment. In their efforts to revitalize Downtown Phoenix, pedestrian thermal comfort improvements became one of the main aims for City planners. There has been an effort in reformulating City zoning standards and building codes with the goal of developing a pedestrian friendly civic environment. Much of the literature dealing with mitigating UHI effects recommends extensive tree planting as the chief strategy for reducing the UHI and improving outdoor human thermal comfort. On the pedestrian scale, vegetation plays a significant role in modifying the microclimate by providing shade and aiding the human thermal comfort via evapotranspiration. However, while the extensive tree canopy is beneficial in providing daytime shade for pedestrians, it may reduce the pavement surfaces' sky-view factor during the night, thereby reducing the rate of nighttime radiation to the sky and trapping the heat gained within the urban materials. This study strives to extend the understanding, and optimize the recommendations for the use of landscape in the urban context of Phoenix, Arizona for effectiveness in both improving the human thermal comfort and in mitigating the urban heat island effect.
ContributorsRosheidat, Akram (Author) / Bryan, Harvey (Thesis advisor) / Lee, Taewoo (Committee member) / Chalfoun, Nader (Committee member) / Arizona State University (Publisher)
Created2014
150100-Thumbnail Image.png
Description
This study examines the applicability of high dynamic range (HDR) imagery as a diagnostic tool for studying lighting quality in interior environments. It originates from the limitations in lighting quality assessments, particularly from the problematic nature of measuring luminance contrast--a significant lighting quality definer. In this research, HDR imaging method

This study examines the applicability of high dynamic range (HDR) imagery as a diagnostic tool for studying lighting quality in interior environments. It originates from the limitations in lighting quality assessments, particularly from the problematic nature of measuring luminance contrast--a significant lighting quality definer. In this research, HDR imaging method is studied systematically and in detail via extensive camera calibration tests considering the effect of lens and light source geometry (i.e. vignetting, point spread and modulation transfer functions), in-camera variables (i.e. spectral response, sensor sensitivity, metering mode,), and environmental variables (i.e. ambient light level, surface color and reflectance, light source spectral power distribution) on the accuracy of HDR-image-derived luminance data. The calibration test findings are used to create camera setup and calibration guidelines for future research, especially to help minimize errors in image extracted lighting data. The findings are also utilized to demonstrate the viability of the tool in a real world setting--an office environment combining vertical and horizontal tasks. Via the quasi-experimental setup, the relationship between line of sight and perceived luminance contrast ratios are studied using HDR images. Future research can benefit from the calibration guidelines to minimize HDR-based luminance estimation errors. The proposed tool can be used and tested in different contexts and tasks with varying user groups for revising the former luminance-contrast guidelines as well as surface reflectance recommendations.
ContributorsTural, Mehmedalp (Author) / Bryan, Harvey (Thesis advisor) / Kroelinger, Michael D. (Committee member) / Ozel, Filiz (Committee member) / Arizona State University (Publisher)
Created2011
151153-Thumbnail Image.png
Description
Due to the lack of understanding of soil thermal behavior, rules-of-thumb and generalized procedures are typically used to guide building professionals in the design of ground coupled heat pump systems. This is especially true when sizing the ground heat exchanger (GHE) loop. Unfortunately, these generalized procedures often encourage building engineers

Due to the lack of understanding of soil thermal behavior, rules-of-thumb and generalized procedures are typically used to guide building professionals in the design of ground coupled heat pump systems. This is especially true when sizing the ground heat exchanger (GHE) loop. Unfortunately, these generalized procedures often encourage building engineers to adopt a conservative design approach resulting in the gross over-sizing of the GHE, thus drastically increasing their installation cost. This conservative design approach is particularly prevalent for buildings located in hot and arid climates, where the soils are often granular and where the water table tends to exist deep below the soil surface. These adverse soil conditions reduce the heat dissipation efficiency of the GHE and have hindered the adoption of ground coupled heat pump systems in such climates. During cooling mode operation, heat is extracted from the building and rejected into the ground via the GHE. Prolonged heat dissipation into the ground can result in a coupled flow of both heat and moisture, causing the moisture to migrate away from the GHE piping. This coupled flow phenomenon causes the soil near the GHE to dry out and results in the degradation of the GHE heat dissipation capacity. Although relatively simple techniques of backfilling the GHE have been used in practice to mitigate such coupled effects, methods of improving the thermal behavior of the backfill region around the GHE, especially in horizontal systems, have not been extensively studied. This thesis presents an experimental study of heat dissipation from a horizontal GHE, buried in two backfill materials: (1) dry sand, and (2) wax-sand composite mixture. The HYDRUS software was then used to numerically model the temperature profiles associated with the aforementioned backfill conditions, and the influence of the contact resistance at the GHE-backfill interface was studied. The modeling strategy developed in HYDRUS was proven to be adequate in predicting the thermal performance of GHE buried in dry sand. However, when predicting the GHE heat dissipation in the wax-sand backfill, significant discrepancies between model prediction and experimental results still exist even after calibrating the model by including a term for the contact resistance. Overall, the thermal properties of the backfill were determined to be a key determinant of the GHE heat dissipation capacity. In particular, the wax-sand backfill was estimated to dissipate 50-60% more heat than dry sand backfill.
ContributorsDAngelo, Kurtis (Author) / Reddy, T Agami (Thesis advisor) / Bryan, Harvey (Committee member) / Kavazanjian, Edward (Committee member) / Arizona State University (Publisher)
Created2012
150463-Thumbnail Image.png
Description
The Urban Heat Island (UHI) has been known to have been around from as long as people have been urbanizing. The growth and conglomeration of cities in the past century has caused an increase in the intensity and impact of Urban Heat Island, causing significant changes to the micro-climate and

The Urban Heat Island (UHI) has been known to have been around from as long as people have been urbanizing. The growth and conglomeration of cities in the past century has caused an increase in the intensity and impact of Urban Heat Island, causing significant changes to the micro-climate and causing imbalances in the temperature patterns of cities. The urban heat island (UHI) is a well established phenomenon and it has been attributed to the reduced heating loads and increased cooling loads, impacting the total energy consumption of affected buildings in all climatic regions. This thesis endeavors to understand the impact of the urban heat island on the typical buildings in the Phoenix Metropolitan region through an annual energy simulation process spanning through the years 1950 to 2005. Phoenix, as a representative city for the hot-arid cooling-dominated region, would be an interesting example to see how the reduction in heating energy consumption offsets the increased demand for cooling energy in the building. The commercial reference building models from the Department of Energy have been used to simulate commercial building stock, while for the residential stock a representative residential model prescribing to IECC 2006 standards will be used. The multiyear simulation process will bring forth the energy consumptions of various building typologies, thus highlighting differing impacts on the various building typologies. A vigorous analysis is performed to see the impact on the cooling loads annually, specifically during summer and summer nights, when the impact of the 'atmospheric canopy layer' - urban heat island (UHI) causes an increase in the summer night time minimum and night time average temperatures. This study also shows the disparity in results of annual simulations run utilizing a typical meteorological year (TMY) weather file, to that of the current recorded weather data. The under prediction due to the use of TMY would translate to higher or lower predicted energy savings in the future years, for changes made to the efficiencies of the cooling or heating systems and thermal performance of the built-forms. The change in energy usage patterns caused by higher cooling energy and lesser heating energy consumptions could influence future policies and energy conservation standards. This study could also be utilized to understand the impacts of the equipment sizing protocols currently adopted, equipment use and longevity and fuel swapping as heating cooling ratios change.
ContributorsDoddaballapur, Sandeep (Author) / Bryan, Harvey (Thesis advisor) / Reddy, Agami T (Committee member) / Addison, Marlin (Committee member) / Arizona State University (Publisher)
Created2011
154682-Thumbnail Image.png
Description
Schools all around the country are improving the performance of their buildings by adopting high performance design principles. Higher levels of energy efficiency can pave the way for K-12 Schools to achieve net zero energy (NZE) conditions, a state where the energy generated by on-site renewable sources are sufficient to

Schools all around the country are improving the performance of their buildings by adopting high performance design principles. Higher levels of energy efficiency can pave the way for K-12 Schools to achieve net zero energy (NZE) conditions, a state where the energy generated by on-site renewable sources are sufficient to meet the cumulative annual energy demands of the facility. A key capability for the proliferation of Net Zero Energy Buildings (NZEB) is the need for a design methodology that identifies the optimum mix of energy efficient design features to be incorporated into the building. The design methodology should take into account the interaction effects of various energy efficiency measures as well as their associated costs so that life cycle cost can be minimized for the entire life span of the building.

This research aims at developing such a methodology for generating cost effective net zero energy solutions for school buildings. The Department of Energy (DOE) prototype primary school, meant to serve as the starting baseline, was modeled in the building energy simulation software eQUEST and made compliant with the requirement of ASHRAE 90.1-2007. Commonly used efficiency measures, for which credible initial cost and maintenance data were available, were selected as the parametric design set. An initial sensitivity analysis was conducted by using the Morris Method to rank the efficiency measures in terms of their importance and interaction strengths. A sequential search technique was adopted to search the solution space and identify combinations that lie near the Pareto-optimal front; this allowed various minimum cost design solutions to be identified corresponding to different energy savings levels.

Based on the results of this study, it was found that the cost optimal combination of measures over the 30 year analysis span resulted in an annual energy cost reduction of 47%, while net zero site energy conditions were achieved by the addition of a 435 kW photovoltaic generation system that covered 73% of the roof area. The simple payback period for the additional technology required to achieve NZE conditions was calculated to be 26.3 years and carried a 37.4% premium over the initial building construction cost. The study identifies future work in how to automate this computationally conservative search technique so that it can provide practical feedback to the building designer during all stages of the design process.
ContributorsIslam, Mohammad Moshfiqul (Author) / Reddy, T. Agami (Thesis advisor) / Bryan, Harvey J. (Committee member) / Addison, Marlin (Committee member) / Arizona State University (Publisher)
Created2016
157535-Thumbnail Image.png
Description
The aim of this research study is to develop a passive architectural design morphology, tuned to the Sonoran Desert, which redefines Desert Modernism and integrates: (a) mitigation of heat transfer through the exterior envelope, and (b) use of daylight to inform appropriate architectural massing. The research investigation was delimited

The aim of this research study is to develop a passive architectural design morphology, tuned to the Sonoran Desert, which redefines Desert Modernism and integrates: (a) mitigation of heat transfer through the exterior envelope, and (b) use of daylight to inform appropriate architectural massing. The research investigation was delimited to mid-nineteenth century European modernist examples, and ends with mid-twentieth century modern architecture in the southwestern United States as viewed through the lens of environmental design. The specific focus was on Desert Modernism, a quasi-architectural movement, which purportedly had its beginnings in 1923 with the Coachella Valley, Popinoe Desert Cabin.

A mixed-method research strategy comprised of interpretive-historical research, virtual simulation/modeling analysis and logical argumentation is used. Succinct discussions on desert vernacular design, Modernism’s global propagation, and the International Style reinterpretations were illustrated to introduce the possibility of a relationship between Modernism and the vernacular. A directed examination of climatic responses included within examples of California Modernism, the Case Study Houses and Desert Modernism follows. Three case studies: a) the Frey House II, b) the Triad Apartments, and c) the Analemma House were assessed using virtual simulation and mathematical calculations, to provide conclusive results on the relevance of regionally tuned exterior envelope design and planning tactics for the Phoenix, Arizona area. Together, these findings suggest a correlation between environmental design principles, vernacular architecture, and Modernism.
ContributorsSoltero, Ed (Author) / Zygas, Kestutis (Thesis advisor) / Bryan, Harvey (Thesis advisor) / Domin, Christopher (Committee member) / Arizona State University (Publisher)
Created2019