Matching Items (3)
Filtering by

Clear all filters

154699-Thumbnail Image.png
Description
Unmanned aerial vehicles have received increased attention in the last decade due to their versatility, as well as the availability of inexpensive sensors (e.g. GPS, IMU) for their navigation and control. Multirotor vehicles, specifically quadrotors, have formed a fast growing field in robotics, with the range of applications spanning from

Unmanned aerial vehicles have received increased attention in the last decade due to their versatility, as well as the availability of inexpensive sensors (e.g. GPS, IMU) for their navigation and control. Multirotor vehicles, specifically quadrotors, have formed a fast growing field in robotics, with the range of applications spanning from surveil- lance and reconnaissance to agriculture and large area mapping. Although in most applications single quadrotors are used, there is an increasing interest in architectures controlling multiple quadrotors executing a collaborative task. This thesis introduces a new concept of control involving more than one quadrotors, according to which two quadrotors can be physically coupled in mid-flight. This concept equips the quadro- tors with new capabilities, e.g. increased payload or pursuit and capturing of other quadrotors. A comprehensive simulation of the approach is built to simulate coupled quadrotors. The dynamics and modeling of the coupled system is presented together with a discussion regarding the coupling mechanism, impact modeling and additional considerations that have been investigated. Simulation results are presented for cases of static coupling as well as enemy quadrotor pursuit and capture, together with an analysis of control methodology and gain tuning. Practical implementations are introduced as results show the feasibility of this design.
ContributorsLarsson, Daniel (Author) / Artemiadis, Panagiotis (Thesis advisor) / Marvi, Hamidreza (Committee member) / Berman, Spring (Committee member) / Arizona State University (Publisher)
Created2016
158167-Thumbnail Image.png
Description
Presented in this thesis are two projects that fall under the umbrella of magnetically actuated electronics and robotics for medical applications. First, magnetically actuated tunable soft electronics are discussed in Chapter 2. Wearable and implantable soft electronics are clinically available and commonplace. However, these devices can be taken a ste

Presented in this thesis are two projects that fall under the umbrella of magnetically actuated electronics and robotics for medical applications. First, magnetically actuated tunable soft electronics are discussed in Chapter 2. Wearable and implantable soft electronics are clinically available and commonplace. However, these devices can be taken a step further to improve the lives of their users by adding remote tunability. The four electric units tested were planar inductors, axial inductors, capacitors and resistors. The devices were made of polydimethylsiloxane (PDMS) for flexibility with copper components for conductivity. The units were tuned using magnets and mobile components comprised of iron filings and ferrofluid. The characteristic properties examined for each unit are as follows: inductance and quality factor (Q-factor) for inductors, capacitance and Q-factor for capacitors, and impedance for resistors. There were two groups of tuning tests: quantity effect and position effect of the mobile component. The position of the mobile component had a larger effect on each unit, with 20-23% change in inductance for inductors (from 3.31 µH for planar and 0.44 µH for axial), 12.7% from 2.854 pF for capacitors and 185.3% from 0.353 kΩ for resistors.

Chapter 3 discusses a magnetic needle tracking device with operative assistance from a six degree-of-freedom robotic arm. Traditional needle steering faces many obstacles such as torsional effects, buckling, and small radii of curvature. To improve upon the concept, this project uses permanent magnets in parallel with a tracking system to steer and determine the position and orientation of the needle in real time. The magnet configuration is located at the end effector of the robotic arm. The trajectory of the end effector depends on the needle’s path, and vice versa. The distance the needle travels inside the workspace is tracked by a direct current (DC) motor, to which the needle is tethered. Combining this length with the pose of the end effector, the position and orientation of the needle can be calculated. Simulation of this tracking device has shown the functionality of the system. Testing has been done to confirm that a single magnet pulls the needle through the phantom tissue.
ContributorsEdwards, Dakota (Author) / Marvi, Hamidreza (Thesis advisor) / Lee, Hyunglae (Committee member) / Berman, Spring (Committee member) / Arizona State University (Publisher)
Created2020
158169-Thumbnail Image.png
Description
Needle steering is an extension of manually inserted needles that allows for maneuverability within the body in order to avoid anatomical obstacles and correct for undesired placement errors. Research into needle steering predominantly exploits interaction forces between a beveled tip and the medium, controlling the direction of forces by

Needle steering is an extension of manually inserted needles that allows for maneuverability within the body in order to avoid anatomical obstacles and correct for undesired placement errors. Research into needle steering predominantly exploits interaction forces between a beveled tip and the medium, controlling the direction of forces by applying rotations at the base of the needle shaft in order to steer. These systems are either manually or robotically advanced, but have not achieved clinical relevance due to a multitude of limitations including compression effects in the shaft that cause undesired tissue slicing, torsional friction forces and deflection at tissue boundaries that create control difficulties, and a physical design that inherently restricts the workspace. While most improvements into these systems attempt to innovate the needle design or create tissue models to better understand interaction forces, this paper discusses a promising alternative: magnetic needle steering. Chapter 2 discusses an electromagnetic needle steering system that overcomes all aforementioned issues with traditional steering. The electromagnetic system advances the needle entirely magnetically so it does not encounter any compression or torsion effects, it can steer across tissue-interfaces at various angles of attack (90, 45, 22.5°) with root-mean-square error (RMSE) of 1.2 mm, achieve various radii of curvature as low as 10.2 mm with RMSE of 1.4 mm, and steer along complex 3D paths with RMSE as low as 0.4 mm. Although these results do effectively prove the viability of magnetic steering, the electromagnetic system is limited by a weak magnetic field and small 33mm cubic workspace. In order to overcome these limitations, the use of permanent magnets, which can achieve magnetic forces an order of magnitude larger than similarly sized electromagnetics, is investigated. The needle will be steered toward a permanent magnet configuration that is controlled by a 6 degree-of-freedom robotic manipulator. Three magnet configurations were investigated, two novel ideas that attempt to create local maximum points that stabilize the needle relative to the configuration, and one that pulls the needle toward a single magnet. Ultimately, the last design was found to be most viable to demonstrate the effectiveness of magnetic needle steering.
ContributorsPetras, Alex (Author) / Marvi, Hamidreza (Thesis advisor) / Yong, Sze Z. (Committee member) / Ross, Heather M. (Committee member) / Arizona State University (Publisher)
Created2020