![155813-Thumbnail Image.png](https://d1rbsgppyrdqq4.cloudfront.net/s3fs-public/styles/width_400/public/2021-09/155813-Thumbnail%20Image.png?versionId=koUl9a39nkUJyvVY0XEYL4tNEK3rs.ok&X-Amz-Content-Sha256=UNSIGNED-PAYLOAD&X-Amz-Algorithm=AWS4-HMAC-SHA256&X-Amz-Credential=AKIASBVQ3ZQ42ZLA5CUJ/20240616/us-west-2/s3/aws4_request&X-Amz-Date=20240616T062934Z&X-Amz-SignedHeaders=host&X-Amz-Expires=120&X-Amz-Signature=b2d1236b58001a887704a1162461a6f37ac9f357a30dad9c2aa213d340c35726&itok=OxY3Ioi7)
![158670-Thumbnail Image.png](https://d1rbsgppyrdqq4.cloudfront.net/s3fs-public/styles/width_400/public/2021-08/158670-Thumbnail%20Image.png?versionId=Uny3jxDsf2jinjWCh27EscqJbYdsOquV&X-Amz-Content-Sha256=UNSIGNED-PAYLOAD&X-Amz-Algorithm=AWS4-HMAC-SHA256&X-Amz-Credential=AKIASBVQ3ZQ42ZLA5CUJ/20240616/us-west-2/s3/aws4_request&X-Amz-Date=20240616T040621Z&X-Amz-SignedHeaders=host&X-Amz-Expires=120&X-Amz-Signature=8dd25b2babbb39c3d287709a45661175532485e762fcf731d9cafba01c5f9d64&itok=zQ1ExnRD)
The development of fMREIT for the direct detection of neural activity using conductivity contrast in in vivo settings has been the focus of the research work presented here. An in vivo animal model was developed to detect neural activity initiated changes in neuronal membrane conductivities under external electrical current stimulation. Neural activity was induced in somatosensory areas I (SAI) and II (SAII) by applying electrical currents between the second and fourth digits of the rodent forepaw. The in vivo animal model involved the use of forepaw stimulation to evoke somatosensory neural activations along with hippocampal fMREIT imaging currents contemporaneously applied under magnetic field strengths of 7 Tesla. Three distinct types of fMREIT current waveforms were applied as imaging currents under two inhalants – air and carbogen. Active regions in the somatosensory cortex showed significant apparent conductivity changes as variations in fMREIT phase (φ_d and ∇^2 φ_d) signals represented by fMREIT activation maps (F-tests, p <0.05). Consistent changes in the standard deviation of φ_d and ∇^2 φ_d in cortical voxels contralateral to forepaw stimulation were observed across imaging sessions. These preliminary findings show that fMREIT may have the potential to detect conductivity changes correlated with neural activity.
![158833-Thumbnail Image.png](https://d1rbsgppyrdqq4.cloudfront.net/s3fs-public/styles/width_400/public/2021-09/158833-Thumbnail%20Image.png?versionId=bO9D.jyw4fMuQy3MQ9f7Nt2dE1AuUadZ&X-Amz-Content-Sha256=UNSIGNED-PAYLOAD&X-Amz-Algorithm=AWS4-HMAC-SHA256&X-Amz-Credential=AKIASBVQ3ZQ42ZLA5CUJ/20240616/us-west-2/s3/aws4_request&X-Amz-Date=20240616T091149Z&X-Amz-SignedHeaders=host&X-Amz-Expires=120&X-Amz-Signature=5fa58d3be7b5ae847c20d5aca375537bf7fa536e48a17d0f54956ee423390517&itok=o67sMiL2)
The second study used the same behavioral paradigm, but targeted tFUS to the right anterior insula/frontal operculum (aIns/fO). The aIns/fO is implicated in saliency, cognitive control, interoceptive awareness, autonomic function, and emotion. tFUS was found to significantly alter ERP, ERSP, conflict and error processing, and HRV responses.
The third study targeted tFUS to the right inferior frontal gyrus (rIFG), employing the Stop Signal task to study inhibition. tFUS affected ERPs and improved stopping speed. Using network modeling, causal evidence is presented for rIFG influence on subcortical nodes in stopping.
This work provides preliminarily evidence that tFUS can be used to modulate broader network function through a single node, affecting neurophysiological processing, physiologic responses, and behavioral performance. Additionally it can be used as a tool to elucidate network function. These studies suggest tFUS has the potential to affect cognitive function as a clinical tool, and perhaps even enhance wellbeing and expand conscious awareness.
![158383-Thumbnail Image.png](https://d1rbsgppyrdqq4.cloudfront.net/s3fs-public/styles/width_400/public/2021-09/158383-Thumbnail%20Image.png?versionId=FVYzBPxyC1Iqh1VACJiIxueM_sNVzm47&X-Amz-Content-Sha256=UNSIGNED-PAYLOAD&X-Amz-Algorithm=AWS4-HMAC-SHA256&X-Amz-Credential=AKIASBVQ3ZQ42ZLA5CUJ/20240616/us-west-2/s3/aws4_request&X-Amz-Date=20240616T060810Z&X-Amz-SignedHeaders=host&X-Amz-Expires=120&X-Amz-Signature=5c83ba494ddfc64029a62004f63a79e1756c6b742aa6ab2ac996cc5a945a67f4&itok=zVUtp36o)
Biomechanical Micromotion at the Neural Interface Modulates Intercellular Membrane Potential In-Vivo
![128536-Thumbnail Image.png](https://d1rbsgppyrdqq4.cloudfront.net/s3fs-public/styles/width_400/public/2021-04/128536-Thumbnail%20Image.png?versionId=a_9F5XBWxJZhyy1kFmv2ioQZKl44oIcA&X-Amz-Content-Sha256=UNSIGNED-PAYLOAD&X-Amz-Algorithm=AWS4-HMAC-SHA256&X-Amz-Credential=AKIASBVQ3ZQ42ZLA5CUJ/20240616/us-west-2/s3/aws4_request&X-Amz-Date=20240616T092509Z&X-Amz-SignedHeaders=host&X-Amz-Expires=120&X-Amz-Signature=d046f1b12f42b245119ed21d3ff59998bedd02e1260cf5f987fcf42064aec508&itok=FpGF4o_9)
The extensive distribution and simultaneous termination of seizures across cortical areas has led to the hypothesis that seizures are caused by large-scale coordinated networks spanning these areas. This view, however, is difficult to reconcile with most proposed mechanisms of seizure spread and termination, which operate on a cellular scale. We hypothesize that seizures evolve into self-organized structures wherein a small seizing territory projects high-intensity electrical signals over a broad cortical area. Here we investigate human seizures on both small and large electrophysiological scales. We show that the migrating edge of the seizing territory is the source of travelling waves of synaptic activity into adjacent cortical areas. As the seizure progresses, slow dynamics in induced activity from these waves indicate a weakening and eventual failure of their source. These observations support a parsimonious theory for how large-scale evolution and termination of seizures are driven from a small, migrating cortical area.
![128329-Thumbnail Image.png](https://d1rbsgppyrdqq4.cloudfront.net/s3fs-public/styles/width_400/public/2022-04/128329-thumbnail-image.png?versionId=IP3FXgIzjDOYIHE1htOwBe9rCAVLxbFU&X-Amz-Content-Sha256=UNSIGNED-PAYLOAD&X-Amz-Algorithm=AWS4-HMAC-SHA256&X-Amz-Credential=AKIASBVQ3ZQ42ZLA5CUJ/20240616/us-west-2/s3/aws4_request&X-Amz-Date=20240616T062934Z&X-Amz-SignedHeaders=host&X-Amz-Expires=120&X-Amz-Signature=e8b2119c9138a3dd258d14fd7a850311a42635cc6b55997c38324fc0ce1cbce1&itok=XMaLZB0p)
The emerging field of neuroprosthetics is focused on the development of new therapeutic interventions that will be able to restore some lost neural function by selective electrical stimulation or by harnessing activity recorded from populations of neurons. As more and more patients benefit from these approaches, the interest in neural interfaces has grown significantly and a new generation of penetrating microelectrode arrays are providing unprecedented access to the neurons of the central nervous system (CNS). These microelectrodes have active tip dimensions that are similar in size to neurons and because they penetrate the nervous system, they provide selective access to these cells (within a few microns). However, the very long-term viability of chronically implanted microelectrodes and the capability of recording the same spiking activity over long time periods still remain to be established and confirmed in human studies. Here we review the main responses to acute implantation of microelectrode arrays, and emphasize that it will become essential to control the neural tissue damage induced by these intracortical microelectrodes in order to achieve the high clinical potentials accompanying this technology.
![153498-Thumbnail Image.png](https://d1rbsgppyrdqq4.cloudfront.net/s3fs-public/styles/width_400/public/2021-09/153498-Thumbnail%20Image.png?versionId=gks5OFwRrD6b3wOnaHvdpW0.o3xzSize&X-Amz-Content-Sha256=UNSIGNED-PAYLOAD&X-Amz-Algorithm=AWS4-HMAC-SHA256&X-Amz-Credential=AKIASBVQ3ZQ42ZLA5CUJ/20240616/us-west-2/s3/aws4_request&X-Amz-Date=20240616T024645Z&X-Amz-SignedHeaders=host&X-Amz-Expires=120&X-Amz-Signature=fa88145039b8d1b9f4e1426b6c20bfbc52879796cfa29d08a65f0c43830cebf1&itok=X0R657m1)
Humans desire compliant robots to safely interact in dynamic environments
associated with daily activities. As surface electromyography non-invasively measures
limb motion intent and correlates with joint stiness during co-contractions,
it has been identied as a candidate for naturally controlling such robots. However,
state-of-the-art myoelectric interfaces have struggled to achieve both enhanced
functionality and long-term reliability. As demands in myoelectric interfaces trend
toward simultaneous and proportional control of compliant robots, robust processing
of multi-muscle coordinations, or synergies, plays a larger role in the success of the
control scheme. This dissertation presents a framework enhancing the utility of myoelectric
interfaces by exploiting motor skill learning and
exible muscle synergies for
reliable long-term simultaneous and proportional control of multifunctional compliant
robots. The interface is learned as a new motor skill specic to the controller,
providing long-term performance enhancements without requiring any retraining or
recalibration of the system. Moreover, the framework oers control of both motion
and stiness simultaneously for intuitive and compliant human-robot interaction. The
framework is validated through a series of experiments characterizing motor learning
properties and demonstrating control capabilities not seen previously in the literature.
The results validate the approach as a viable option to remove the trade-o
between functionality and reliability that have hindered state-of-the-art myoelectric
interfaces. Thus, this research contributes to the expansion and enhancement of myoelectric
controlled applications beyond commonly perceived anthropomorphic and
\intuitive control" constraints and into more advanced robotic systems designed for
everyday tasks.
![156810-Thumbnail Image.png](https://d1rbsgppyrdqq4.cloudfront.net/s3fs-public/styles/width_400/public/2021-08/156810-Thumbnail%20Image.png?versionId=KWRAu524Bp0eowjL_KL.QkYIujLoJ4.O&X-Amz-Content-Sha256=UNSIGNED-PAYLOAD&X-Amz-Algorithm=AWS4-HMAC-SHA256&X-Amz-Credential=AKIASBVQ3ZQ42ZLA5CUJ/20240616/us-west-2/s3/aws4_request&X-Amz-Date=20240616T092509Z&X-Amz-SignedHeaders=host&X-Amz-Expires=120&X-Amz-Signature=5798bce05838ee16fb419cc7f11b004fb9b67f4b05722abc7bbafa6c2fc49c53&itok=KKjRV0Ue)
The scale at which non-penetrating electrode arrays can interface with cortex is evaluated in the context of extracting useful information. Articulate movements were decoded from surface microelectrode electrodes, and additional spatial analysis revealed unique signal content despite dense electrode spacing. With a basis for data extraction established, the focus shifts towards the information encoding half of neural interfaces. Finite element modeling was used to compare tissue recruitment under surface stimulation across electrode scales. Results indicated charge density-based metrics provide a reasonable approximation for current levels required to evoke a visual sensation and showed tissue recruitment increases exponentially with electrode diameter. Micro-scale electrodes (0.1 – 0.3 mm diameter) could sufficiently activate layers II/III in a model tuned to striate cortex while maintaining focal radii of activated tissue.
In vivo testing proceeded in a nonhuman primate model. Stimulation consistently evoked visual percepts at safe current thresholds. Tracking perception thresholds across one year reflected stable values within minimal fluctuation. Modulating waveform parameters was found useful in reducing charge requirements to evoke perception. Pulse frequency and phase asymmetry were each used to reduce thresholds, improve charge efficiency, lower charge per phase – charge density metrics associated with tissue damage. No impairments to photic perception were observed during the course of the study, suggesting limited tissue damage from array implantation or electrically induced neurotoxicity. The subject consistently identified stimulation on closely spaced electrodes (2 mm center-to-center) as separate percepts, indicating sub-visual degree discrete resolution may be feasible with this platform. Although continued testing is necessary, preliminary results supports epicortical microelectrode arrays as a stable platform for interfacing with neural tissue and a viable option for bi-directional BCI applications.