Matching Items (220)
148155-Thumbnail Image.png
Description

A novel concept for integration of flame-assisted fuel cells (FFC) with a gas turbine is analyzed in this paper. Six different fuels (CH4, C3H8, JP-4, JP-5, JP-10(L), and H2) are investigated for the analytical model of the FFC integrated gas turbine hybrid system. As equivalence ratio increases, the efficiency of

A novel concept for integration of flame-assisted fuel cells (FFC) with a gas turbine is analyzed in this paper. Six different fuels (CH4, C3H8, JP-4, JP-5, JP-10(L), and H2) are investigated for the analytical model of the FFC integrated gas turbine hybrid system. As equivalence ratio increases, the efficiency of the hybrid system increases initially then decreases because the decreasing flow rate of air begins to outweigh the increasing hydrogen concentration. This occurs at an equivalence ratio of 2 for CH4. The thermodynamic cycle is analyzed using a temperature entropy diagram and a pressure volume diagram. These thermodynamic diagrams show as equivalence ratio increases, the power generated by the turbine in the hybrid setup decreases. Thermodynamic analysis was performed to verify that energy is conserved and the total chemical energy going into the system was equal to the heat rejected by the system plus the power generated by the system. Of the six fuels, the hybrid system performs best with H2 as the fuel. The electrical efficiency with H2 is predicted to be 27%, CH4 is 24%, C3H8 is 22%, JP-4 is 21%, JP-5 is 20%, and JP-10(L) is 20%. When H2 fuel is used, the overall integrated system is predicted to be 24.5% more efficient than the standard gas turbine system. The integrated system is predicted to be 23.0% more efficient with CH4, 21.9% more efficient with C3H8, 22.7% more efficient with JP-4, 21.3% more efficient with JP-5, and 20.8% more efficient with JP-10(L). The sensitivity of the model is investigated using various fuel utilizations. When CH4 fuel is used, the integrated system is predicted to be 22.7% more efficient with a fuel utilization efficiency of 90% compared to that of 30%.

ContributorsRupiper, Lauren Nicole (Author) / Milcarek, Ryan (Thesis director) / Wang, Liping (Committee member) / Mechanical and Aerospace Engineering Program (Contributor) / School for Engineering of Matter,Transport & Enrgy (Contributor) / Barrett, The Honors College (Contributor)
Created2021-05
152239-Thumbnail Image.png
Description
Production from a high pressure gas well at a high production-rate encounters the risk of operating near the choking condition for a compressible flow in porous media. The unbounded gas pressure gradient near the point of choking, which is located near the wellbore, generates an effective tensile stress on the

Production from a high pressure gas well at a high production-rate encounters the risk of operating near the choking condition for a compressible flow in porous media. The unbounded gas pressure gradient near the point of choking, which is located near the wellbore, generates an effective tensile stress on the porous rock frame. This tensile stress almost always exceeds the tensile strength of the rock and it causes a tensile failure of the rock, leading to wellbore instability. In a porous rock, not all pores are choked at the same flow rate, and when just one pore is choked, the flow through the entire porous medium should be considered choked as the gas pressure gradient at the point of choking becomes singular. This thesis investigates the choking condition for compressible gas flow in a single microscopic pore. Quasi-one-dimensional analysis and axisymmetric numerical simulations of compressible gas flow in a pore scale varicose tube with a number of bumps are carried out, and the local Mach number and pressure along the tube are computed for the flow near choking condition. The effects of tube length, inlet-to-outlet pressure ratio, the number of bumps and the amplitude of the bumps on the choking condition are obtained. These critical values provide guidance for avoiding the choking condition in practice.
ContributorsYuan, Jing (Author) / Chen, Kangping (Thesis advisor) / Wang, Liping (Committee member) / Huang, Huei-Ping (Committee member) / Arizona State University (Publisher)
Created2013
151485-Thumbnail Image.png
Description
Tesla turbo-machinery offers a robust, easily manufactured, extremely versatile prime mover with inherent capabilities making it perhaps the best, if not the only, solution for certain niche applications. The goal of this thesis is not to optimize the performance of the Tesla turbine, but to compare its performance with various

Tesla turbo-machinery offers a robust, easily manufactured, extremely versatile prime mover with inherent capabilities making it perhaps the best, if not the only, solution for certain niche applications. The goal of this thesis is not to optimize the performance of the Tesla turbine, but to compare its performance with various working fluids. Theoretical and experimental analyses of a turbine-generator assembly utilizing compressed air, saturated steam and water as the working fluids were performed and are presented in this work. A brief background and explanation of the technology is provided along with potential applications. A theoretical thermodynamic analysis is outlined, resulting in turbine and rotor efficiencies, power outputs and Reynolds numbers calculated for the turbine for various combinations of working fluids and inlet nozzles. The results indicate the turbine is capable of achieving a turbine efficiency of 31.17 ± 3.61% and an estimated rotor efficiency 95 ± 9.32%. These efficiencies are promising considering the numerous losses still present in the current design. Calculation of the Reynolds number provided some capability to determine the flow behavior and how that behavior impacts the performance and efficiency of the Tesla turbine. It was determined that turbulence in the flow is essential to achieving high power outputs and high efficiency. Although the efficiency, after peaking, begins to slightly taper off as the flow becomes increasingly turbulent, the power output maintains a steady linear increase.
ContributorsPeshlakai, Aaron (Author) / Phelan, Patrick (Thesis advisor) / Trimble, Steve (Committee member) / Wang, Liping (Committee member) / Arizona State University (Publisher)
Created2012
148412-Thumbnail Image.png
Description

This work summarizes the development of a dynamic measurement platform in a cryostat to measure sample temperature response to space-like conditions and the creation a MATLAB theoretical model to predict sample temperature responses in the platform itself. An interesting variable-emittance sample called a Fabry-Perot emitter was studied for its thermal

This work summarizes the development of a dynamic measurement platform in a cryostat to measure sample temperature response to space-like conditions and the creation a MATLAB theoretical model to predict sample temperature responses in the platform itself. An interesting variable-emittance sample called a Fabry-Perot emitter was studied for its thermal homeostasis behavior using the two developments. Using the measurement platform, it was shown that there was no thermal homeostatic behavior demonstrated by the sample at steady state temperatures. Theoretical calculations show other ways to demonstrate the cooling homeostasis behavior through time-varying heat inputs. Factors within the system such as heat loss and thermal mass contributed to an inhibited sample performance in the platform. Future work will have to be conducted, not only to verify the findings of the initial experiments but also to improve the measurement platform and the theoretical model.

ContributorsBoman, Neal D (Author) / Wang, Liping (Thesis director) / Taylor, Syndey (Committee member) / Mechanical and Aerospace Engineering Program (Contributor, Contributor) / Barrett, The Honors College (Contributor)
Created2021-05
148418-Thumbnail Image.png
Description

A thermochromic mid-infrared filter is designed, where a spectrally-selective transmittance peak exists while vanadium dioxide layers are below their transition temperature but broad opaqueness is observed below the transition temperature. This filter takes advantage of interference effects between a silicon spacer and insulating vanadium dioxide to create the transmittance peak

A thermochromic mid-infrared filter is designed, where a spectrally-selective transmittance peak exists while vanadium dioxide layers are below their transition temperature but broad opaqueness is observed below the transition temperature. This filter takes advantage of interference effects between a silicon spacer and insulating vanadium dioxide to create the transmittance peak and the drastic optical property change between insulating and metallic vanadium dioxide. The theoretical performance of the filter in energy dissipation and thermal camouflaging applications is analyzed and can be optimized by tuning the thicknesses of the thin-film layers.

ContributorsChao, Jeremy (Author) / Wang, Liping (Thesis director) / Taylor, Sydney (Committee member) / Mechanical and Aerospace Engineering Program (Contributor, Contributor) / Barrett, The Honors College (Contributor)
Created2021-05
136139-Thumbnail Image.png
Description
Objective: To assess and quantify the effect of state’s price transparency regulations (hereafter, PTR) on healthcare pricing.

Data Sources: I use the Healthcare Cost and Utilization Project’s Nationwide Inpatient Sample (NIS) from 2000 to 2011. The NIS is a 20% sample of all inpatient claims. The Manhattan

Objective: To assess and quantify the effect of state’s price transparency regulations (hereafter, PTR) on healthcare pricing.

Data Sources: I use the Healthcare Cost and Utilization Project’s Nationwide Inpatient Sample (NIS) from 2000 to 2011. The NIS is a 20% sample of all inpatient claims. The Manhattan Institute supplied data on the availability of health savings accounts in each state. State PTR implementation dates were gathered by Hans Christensen, Eric Floyd, and Mark Maffett of University of Chicago’s Booth School of Business by contacting the health department, hospital association, or website controller in each state.

Study Design: The NIS data was collapsed by procedure, hospital, and year providing averages for the dependent variable, Cost, and a host of covariates. Cost is a product of Total Charges within the NIS and the hospital’s Cost to Charge ratio. A new binary variable, PTR, was defined as ‘0’ if the year was strictly less than the disclosure website’s implementation date, ‘1’ for afterwards, and missing for the year of implementation. Then, using multivariate OLS regression with fixed effect modeling, the change in cost from before to after the year of implementation is estimated.

Principal Findings: The analysis estimates the effect of PTR to decrease the average cost per procedure by 7%. Specifications identify within state, within hospital, and within procedure variation, and reports that 78% of the cost decrease is due to within-hospital, within-procedure price discounts. An additional model includes the interaction of PTR with the prevalence of health savings accounts (hereafter, HSAs) and procedure electivity. The results show that PTR lowers costs by an additional 3 percent with each additional 10 percentage point increase in the availability of HSAs. In contrast, the cost reductions from PTR were much smaller for procedures more frequently coded as elective.

Conclusions: The study concludes price transparency regulations can lead to a decrease in a procedure’s costs on average, primarily through price discounts and slightly through lower cost procedures, but not due to patients moving to cheaper hospitals. This implies that hospitals are taking initiative and lowering prices as the competition’s prices become publically available suggesting that hospitals – not patients – are the biggest users of price transparency websites. Hospitals are also finding some ways to provide cheaper alternatives to more expensive procedures. State regulators should evaluate if a better metric other than charge prices, such as expected out-of-pocket payments, would evoke greater patient participation. Furthermore, states with higher prevalence of HSAs experience greater effects of PTR as expected since patients with HSAs have greater incentives to lower their costs. Patients should expect a shift towards plans that offer these types of savings accounts since they’ve shown to have a reduction of health costs on average per procedure in states with higher prevalence of HSAs.
ContributorsSabol, Joshua Lawrence (Author) / Reiser, Mark (Thesis director) / Ketcham, Jonathan (Committee member) / Dassanayake, Maduranga (Committee member) / Barrett, The Honors College (Contributor) / School of Mathematical and Statistical Sciences (Contributor) / Department of Supply Chain Management (Contributor)
Created2015-05
136184-Thumbnail Image.png
Description
Currently, the medical industry employs an acute treatment process centered on responsiveness and restoration. This method fails those with chronic illness who require disease management and proactivity. As a solution, the medical industry has implemented programs focused on providing integrated, coordinated care. This project examines two primary models to accommodate

Currently, the medical industry employs an acute treatment process centered on responsiveness and restoration. This method fails those with chronic illness who require disease management and proactivity. As a solution, the medical industry has implemented programs focused on providing integrated, coordinated care. This project examines two primary models to accommodate chronically ill patients: Accountable Care Organizations (ACOs) and Patient Centered Medical Homes (PCMHs). Specifically, this paper examines the data from Pioneer and Medicare Shared Savings Program ACOs. In the aggregate, the data indicate that these programs have been unsuccessful due to several key issues: a lack of patient and physician engagement, failure to incentivize medical professionals and failed collaboration between both ACOs and PCMHs. Remedying these issues would improve the ability of both ACOs and PCMHs to provide integrated, comprehensive care to patients with chronic illnesses.
ContributorsWoods, Cassie Marie (Author) / Ketcham, Jonathan (Thesis director) / Samper, Adriana (Committee member) / Barrett, The Honors College (Contributor) / Department of Marketing (Contributor)
Created2015-05
135609-Thumbnail Image.png
Description
Zeolitic Imidazolate Frameworks (ZIFs) are a promising technology for the separation of gases. ZIFs represent a type of hybrid material that is a subset of metal organic frameworks while displaying zeolite properties. ZIFs have tunable pore metrics, high thermal stability, and large surface areas giving them advantages over traditional zeolites.

Zeolitic Imidazolate Frameworks (ZIFs) are a promising technology for the separation of gases. ZIFs represent a type of hybrid material that is a subset of metal organic frameworks while displaying zeolite properties. ZIFs have tunable pore metrics, high thermal stability, and large surface areas giving them advantages over traditional zeolites. The experiment sought to determine the flux of hexane vapor through ZIF-68 with Fourier Transform Infrared Spectroscopy (FTIR) mapping. FTIR mapping was used to obtain three spectra per crystal and the concentration gradient was analyzed to determine the flux. ZIF-68 was completely stable when loaded with hexane and exposed to the atmosphere. There was no hexane diffusion out of the crystal. As a result, ZIF-68 was heated to 50°C to increase diffusion and calculate the flux. ZIF-68 adhered to Knudsen Diffusion, and the flux was calculated to be 2.00*10-5 kg mol/s*m2. The small flux occurred because almost no concentration gradient was obtained through the crystal. It was hypothesized that the resistance in the crystal was substantially lower than the resistance at the boundary layer, which would have caused a small concentration gradient. Using film mass transfer theory, the resistance inside the crystal was found to be 1200 times lower than the resistance at the boundary layer confirming the hypothesis.
ContributorsSigrist, Dallas Dale (Author) / Lin, Jerry (Thesis director) / Wang, Liping (Committee member) / Chemical Engineering Program (Contributor) / Barrett, The Honors College (Contributor)
Created2016-05
137032-Thumbnail Image.png
Description
The healthcare industry is currently facing significant changes. One of the changes in the industry is a movement towards patient-focused care, which considers the patient as a person and the impact of care on the person. Patient experience is part of patient-focused care, and has similarities to the marketing term

The healthcare industry is currently facing significant changes. One of the changes in the industry is a movement towards patient-focused care, which considers the patient as a person and the impact of care on the person. Patient experience is part of patient-focused care, and has similarities to the marketing term customer experience, which contributes to happier customers and long-term financial growth and success for businesses. This thesis defines current issues in patient experience as it relates to hospital manager decision making. Through secondary research, this thesis demonstrates what patient experience is, the role it plays in healthcare and hospital settings, the pressures on hospitals to increase patient experience performance, how patient experience performance is measured, and what strategies or action drive improvements under current performance measurements. Many studies and articles exist examining each of these issues individually. However, these sources do not comprehensively define patient experience in hospitals with perspective on how this influences hospital strategy and decision-making. Previous works on patient experience from the perspective of hospital strategy do not include considerations for recent industry shifts, most notably the Patient Protection and Affordable Care Act. The collected definitions in this thesis provide guidance of relevant concerns hospital managers consider when formulating organization-wide strategy related to patient experience. This thesis explains how patient experience contributes to the success of hospitals in the short-term, medium-term, and long-term and how patient experience may shift its focus over time. Short-term concerns include specific regulations and definitions from the Centers for Medicare and Medicaid services, responsible for over half of all payments to hospitals. Conforming to CMS standards is a matter of survival for most hospitals in the short-term. Hospitals are adjusting to rules and payment models not in existence just two years ago. First, hospitals will adapt, and then hospitals will strive to optimize under new standards as well as respond to adjustments in the rules over the next several years. After patient experience standards are well established, certain aspects of patient experience will be part of long-term differentiation and success for hospitals. Responding comprehensively to the shift towards improving patient experience is a critical aspect for hospitals to weather the many changes in the healthcare industry. Patient experience will provide better care to patients and better financial health to the hospitals that perform above patient experience standards.
ContributorsWilton, Kara Alexandra (Author) / Ketcham, Jonathan (Thesis director) / Ostrom, Amy (Committee member) / Barrett, The Honors College (Contributor) / W. P. Carey School of Business (Contributor) / Department of Supply Chain Management (Contributor) / Department of Marketing (Contributor)
Created2014-05
137259-Thumbnail Image.png
Description
Prenatal care is a widely administered preventative care service, and its adequate use has been shown to decrease poor infant and maternal health outcomes. Today however, in the United States, preterm birth rates remain among the highest in the industrialized world, with low socioeconomic women having the highest risk of

Prenatal care is a widely administered preventative care service, and its adequate use has been shown to decrease poor infant and maternal health outcomes. Today however, in the United States, preterm birth rates remain among the highest in the industrialized world, with low socioeconomic women having the highest risk of preterm births. This group of women also face the greatest barriers to access adequate prenatal care in the United States. This paper explores the viability of short message service to help bridge gaps in prenatal care for low socioeconomic women in the United States and provides areas for further research.
ContributorsMiles, Kelly Nicole (Author) / Ketcham, Jonathan (Thesis director) / Santanam, Raghu (Committee member) / Barrett, The Honors College (Contributor) / W. P. Carey School of Business (Contributor) / Department of Marketing (Contributor) / Department of Finance (Contributor)
Created2014-05